Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry

被引:5
|
作者
Radojcic, Deni Smilovic [1 ]
Rajlic, David [1 ]
Casar, Bozidar [2 ]
Kolacio, Manda Svabic [1 ]
Obajdin, Nevena [1 ]
Faj, Dario [3 ,4 ]
Jurkovic, Slaven [1 ,5 ]
机构
[1] Univ Hosp Rijeka, Med Phys Dept, Kresimirova 42, Rijeka, Croatia
[2] Inst Oncol LJubljana, Dept Radiat Phys, Ljubljana, Slovenia
[3] Univ Osijek, Fac Med, Osijek, Croatia
[4] Univ Osijek, Fac Dent Med & Hlth, Osijek, Croatia
[5] Univ Rijeka, Dept Med Phys & Biophys, Fac Med, Rijeka, Croatia
关键词
IMRT; 2D dose verification; gamma method; anthropomorphic phantom; WATER; VERIFICATION; PHOTON; TISSUE; BEAMS; FILM;
D O I
10.2478/raon-2018-0019
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. The accuracy of dose calculation is crucial for success of the radiotherapy treatment. One of the methods that represent the current standard for patient-specific dosimetry is the evaluation of dose distributions measured with an ionization chamber array inside a homogeneous phantom using gamma method. Nevertheless, this method does not replicate the realistic conditions present when a patient is undergoing therapy. Therefore, to more accurately evaluate the treatment planning system (TPS) capabilities, gamma passing rates were examined for beams of different complexity passing through inhomogeneous phantoms. Materials and methods. The research was performed using Siemens Oncor Expression linear accelerator, Siemens Somatom Open CT simulator and Elekta Monaco TPS. A 2D detector array was used to evaluate dose distribution accuracy in homogeneous, semi-anthropomorphic and anthropomorphic phantoms. Validation was based on gamma analysis with 3%/3mm and 2%/2mm criteria, respectively. Results. Passing rates of the complex dose distributions degrade depending on the thickness of non-water equivalent material. They also depend on dose reporting mode used. It is observed that the passing rate decreases with plan complexity. Comparison of the data for all set-ups of semi-anthropomorphic and anthropomorphic phantoms shows that passing rates are higher in the anthropomorphic phantom. Conclusions. Presented results raise a question of possible limits of dose distribution verification in assessment of plan delivery quality. Consequently, good results obtained using standard patient specific dosimetry methodology do not guarantee the accuracy of delivered dose distribution in real clinical cases.
引用
收藏
页码:346 / 352
页数:7
相关论文
共 50 条
  • [41] Development of a patient-specific 3D dose evaluation program for QA in radiation therapy
    Lee, Suk
    Chang, Kyung Hwan
    Cao, Yuan Jie
    Shim, Jang Bo
    Yang, Dae Sik
    Park, Young Je
    Yoon, Won Sup
    Kim, Chul Yong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (06) : 859 - 866
  • [42] Quality assurance device for four-dimensional IMRT or SBRT and respiratory gating using patient-specific intrafraction motion kernels
    Nelms, Benjamin E.
    Ehler, Eric
    Bragg, Henry
    Tome, Wolfgang A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (04): : 152 - 168
  • [43] Time-Resolved Versus Integrated Transit Planar Dosimetry for Volumetric Modulated Arc Therapy: Patient-Specific Dose Differences During Treatment, a Proof of Principle
    Persoon, L. C. G. G.
    Podesta, M.
    Nijsten, S. M. J. J. G.
    Troost, E. G. C.
    Verhaegen, F.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : NP79 - NP87
  • [44] The Impact of Tissue Type and Density on Dose Point Kernels for Patient-Specific Voxel-Wise Dosimetry: A Monte Carlo Investigation
    Tiwari, Ashok
    Graves, Stephen A.
    Sunderland, John
    RADIATION RESEARCH, 2020, 193 (06) : 531 - 542
  • [45] A systems theory-based safety assessment of pre-treatment patient-specific quality assurance for intensity-modulated treatments in a single-vendor environment
    Wong, Lawrence M.
    Pawlicki, Todd
    RADIOTHERAPY AND ONCOLOGY, 2024, 201
  • [46] Patient-Specific Three-Dimensional Concomitant Dose From Cone Beam Computed Tomography Exposure in Image-Guided Radiotherapy
    Spezi, Emiliano
    Downes, Patrick
    Jarvis, Richard
    Radu, Emil
    Staffurth, John
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01): : 419 - 426
  • [47] A Bayesian control chart based on the beta distribution for monitoring the two-dimensional gamma index pass rate in the context of patient-specific quality assurance
    Tiplica, Teodor
    Dufreneix, Stephane
    Legrand, Christophe
    MEDICAL PHYSICS, 2020, 47 (11) : 5408 - 5418
  • [48] Application of TG-218 action limits to SRS and SBRT pre-treatment patient specific QA
    Xia, Yuqing
    Adamson, Justus
    Zlateva, Yana
    Giles, Will
    JOURNAL OF RADIOSURGERY AND SBRT, 2020, 7 (02): : 135 - 147
  • [49] Treatment plan prescreening for patient-specific quality assurance measurements using independent Monte Carlo dose calculations
    Xu, Yuan
    Zhang, Ke
    Liu, Zhiqiang
    Liang, Bin
    Ma, Xiangyu
    Ren, Wenting
    Men, Kuo
    Dai, Jianrong
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [50] Development of in-house heterogeneous thorax phantom and evaluation of pretreatment patient-specific transit dosimetry for intensity-modulated radiotherapy and volumetric modulated arc therapy plans
    Bagdare, Priyusha
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2022, 18 (04) : 1098 - 1104