Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry

被引:5
|
作者
Radojcic, Deni Smilovic [1 ]
Rajlic, David [1 ]
Casar, Bozidar [2 ]
Kolacio, Manda Svabic [1 ]
Obajdin, Nevena [1 ]
Faj, Dario [3 ,4 ]
Jurkovic, Slaven [1 ,5 ]
机构
[1] Univ Hosp Rijeka, Med Phys Dept, Kresimirova 42, Rijeka, Croatia
[2] Inst Oncol LJubljana, Dept Radiat Phys, Ljubljana, Slovenia
[3] Univ Osijek, Fac Med, Osijek, Croatia
[4] Univ Osijek, Fac Dent Med & Hlth, Osijek, Croatia
[5] Univ Rijeka, Dept Med Phys & Biophys, Fac Med, Rijeka, Croatia
关键词
IMRT; 2D dose verification; gamma method; anthropomorphic phantom; WATER; VERIFICATION; PHOTON; TISSUE; BEAMS; FILM;
D O I
10.2478/raon-2018-0019
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. The accuracy of dose calculation is crucial for success of the radiotherapy treatment. One of the methods that represent the current standard for patient-specific dosimetry is the evaluation of dose distributions measured with an ionization chamber array inside a homogeneous phantom using gamma method. Nevertheless, this method does not replicate the realistic conditions present when a patient is undergoing therapy. Therefore, to more accurately evaluate the treatment planning system (TPS) capabilities, gamma passing rates were examined for beams of different complexity passing through inhomogeneous phantoms. Materials and methods. The research was performed using Siemens Oncor Expression linear accelerator, Siemens Somatom Open CT simulator and Elekta Monaco TPS. A 2D detector array was used to evaluate dose distribution accuracy in homogeneous, semi-anthropomorphic and anthropomorphic phantoms. Validation was based on gamma analysis with 3%/3mm and 2%/2mm criteria, respectively. Results. Passing rates of the complex dose distributions degrade depending on the thickness of non-water equivalent material. They also depend on dose reporting mode used. It is observed that the passing rate decreases with plan complexity. Comparison of the data for all set-ups of semi-anthropomorphic and anthropomorphic phantoms shows that passing rates are higher in the anthropomorphic phantom. Conclusions. Presented results raise a question of possible limits of dose distribution verification in assessment of plan delivery quality. Consequently, good results obtained using standard patient specific dosimetry methodology do not guarantee the accuracy of delivered dose distribution in real clinical cases.
引用
收藏
页码:346 / 352
页数:7
相关论文
共 50 条
  • [21] Pretreatment patient-specific IMRT quality assurance: A correlation study between gamma index and patient clinical dose volume histogram
    Stasi, M.
    Bresciani, S.
    Miranti, A.
    Maggio, A.
    Sapino, V.
    Gabriele, P.
    MEDICAL PHYSICS, 2012, 39 (12) : 7626 - 7634
  • [22] Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions
    Dempsey, JF
    Low, DA
    Mutic, S
    Markman, J
    Kirov, AS
    Nussbaum, GH
    Williamson, JF
    MEDICAL PHYSICS, 2000, 27 (10) : 2462 - 2475
  • [23] Quantitative Evaluation of Patient-Specific Quality Assurance Using Online Dosimetry System
    Jung, Jae-Yong
    Shin, Young-Ju
    Sohn, Seung-Chang
    Min, Jung-Whan
    Kim, Yon-Lae
    Kim, Dong-Su
    Choe, Bo-Young
    Suh, Tae-Suk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 72 (02) : 312 - 319
  • [24] Three-dimensional dose prediction based on two-dimensional verification measurements for IMRT
    Sumida, Iori
    Yamaguchi, Hajime
    Kizaki, Hisao
    Aboshi, Keiko
    Yamada, Yuji
    Yoshioka, Yasuo
    Ogawa, Kazuhiko
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05): : 133 - 146
  • [25] Sensitivity and specificity of Varian Halcyon's portal dosimetry for plan-specific pre-treatment QA
    Razinskas, Gary
    Schindhelm, Robert
    Sauer, Otto A.
    Wegener, Sonja
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (08):
  • [26] Sensitivity evaluation of two commercial quality assurance systems to organ-dose variations of patient-specific VMAT plans
    Oderinde, Oluwaseyi M.
    Du Plessis, Freek
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2019, 12 (01) : 132 - 139
  • [27] 2D dose reconstruction of IMRT patient-specific QA based on log file
    Mubarok, Sayid
    Wahyu, Wibowo Edy
    Supriyanto, Pawiro Ardjo
    RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [28] An investigation of the accuracy of an IMRT dose distribution using two- and three-dimensional dosimetry techniques
    Oldham, Mark
    Sakhalkar, Harshad
    Guo, Pengyi
    Adamovics, John
    MEDICAL PHYSICS, 2008, 35 (05) : 2072 - 2080
  • [29] Three-dimensional printer-generated patient-specific phantom for artificial in vivo dosimetry in radiotherapy quality assurance
    Kamomae, Takeshi
    Shimizu, Hidetoshi
    Nakaya, Takayoshi
    Okudaira, Kuniyasu
    Aoyama, Takahiro
    Oguchi, Hiroshi
    Komori, Masataka
    Kawamura, Mariko
    Ohtakara, Kazuhiro
    Monzen, Hajime
    Itoh, Yoshiyuki
    Naganawa, Shinji
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 205 - 211
  • [30] An investigation of the IQM signal variation and error detection sensitivity for patient specific pre-treatment QA
    Alharthi, Thahabah
    George, Armia
    Arumugam, Sankar
    Holloway, Lois
    Thwaites, David
    Vial, Phil