Imaging performance of phase-contrast breast computed tomography with synchrotron radiation and a CdTe photon-counting detector

被引:51
作者
Sarno, A. [1 ,2 ]
Mettivier, G. [1 ,2 ]
Golosio, B. [3 ,4 ]
Oliva, P. [3 ,4 ]
Spandre, G. [5 ]
Di Lillo, F. [1 ,2 ]
Fedon, C. [6 ,7 ]
Longo, R. [6 ,7 ]
Russo, P. [1 ,2 ]
机构
[1] Univ Naples Federico II, Dipartimento Fis Ettore Pancini, Naples, Italy
[2] INFN Sez Napoli, Naples, Italy
[3] Univ Sassari, I-07100 Sassari, Italy
[4] INFN Sez Cagliari, Cagliari, Italy
[5] INFN Sez Pisa, Pisa, Italy
[6] Univ Trieste, Dipartimento Fis, Trieste, Italy
[7] INFN Sez Trieste, Trieste, Italy
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2016年 / 32卷 / 05期
关键词
Synchrotron radiation; Breast cancer; Photon-counting detector; Computed tomography; Phase-contrast imaging; X-RAY CT; MAMMOGRAPHY; CARCINOMA; OPTIMIZATION; RESOLUTION; HISTOLOGY; BEAMLINE; ELETTRA; TUMOR;
D O I
10.1016/j.ejmp.2016.04.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Within the SYRMA-CT collaboration based at the ELETTRA synchrotron radiation (SR) facility the authors investigated the imaging performance of the phase-contrast computed tomography (CT) system dedicated to monochromatic in vivo 3D imaging of the female breast, for breast cancer diagnosis. Methods: Test objects were imaged at 38 keV using monochromatic SR and a high-resolution CdTe photon-counting detector. Signal and noise performance were evaluated using modulation transfer function (MTF) and noise power spectrum. The analysis was performed on the images obtained with the application of a phase retrieval algorithm as well as on those obtained without phase retrieval. The contrast to noise ratio (CNR) and the capability of detecting test microcalcification clusters and soft masses were investigated. Results: For a voxel size of (60 mu m)(3), images without phase retrieval showed higher spatial resolution (6.7 mm(-1) at 10% MTF) than corresponding images with phase retrieval (2.5 mm(-1)). Phase retrieval produced a reduction of the noise level and an increase of the CNR by more than one order of magnitude, compared to raw phase-contrast images. Microcalcifications with a diameter down to 130 mu m could be detected in both types of images. Conclusions: The investigation on test objects indicates that breast CT with a monochromatic SR source is technically feasible in terms of spatial resolution, image noise and contrast, for in vivo 3D imaging with a dose comparable to that of two-view mammography. Images obtained with the phase retrieval algorithm showed the best performance in the trade-off between spatial resolution and image noise. (C) 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:681 / 690
页数:10
相关论文
共 40 条
[1]   Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA [J].
Abrami, A ;
Arfelli, F ;
Barroso, RC ;
Bergamaschi, A ;
Billé, F ;
Bregant, P ;
Brizzi, F ;
Casarin, K ;
Castelli, E ;
Chenda, V ;
Palma, LD ;
Dreossi, D ;
Fava, A ;
Longo, R ;
Mancini, L ;
Menk, RH ;
Montanari, F ;
Olivo, A ;
Pani, S ;
Pillon, A ;
Quai, E ;
Kaiser, SR ;
Rigon, L ;
Rokvic, T ;
Tonutti, M ;
Tromba, G ;
Vaseotto, A ;
Venanzi, C ;
Zanconati, F ;
Zanetti, A ;
Zanini, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) :221-227
[2]   Chromatic X-ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC [J].
Bellazzini, R. ;
Spandre, G. ;
Brez, A. ;
Minuti, M. ;
Pinchera, M. ;
Mozzo, P. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[3]   Technique factors and their relationship to radiation dose in pendant geometry breast CT [J].
Boone, JM ;
Kwan, ALC ;
Seibert, JA ;
Shah, N ;
Lindfors, KK ;
Nelson, TR .
MEDICAL PHYSICS, 2005, 32 (12) :3767-3776
[4]   Determination of the presampled MTF in computed tomography [J].
Boone, JM .
MEDICAL PHYSICS, 2001, 28 (03) :356-360
[5]   X-ray phase-contrast imaging: from pre-clinical applications towards clinics [J].
Bravin, Alberto ;
Coan, Paola ;
Suortti, Pekka .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01) :R1-R35
[6]  
Cai W, 2009, P SOC PHOTO-OPT INS, DOI DOI 10.1117/12.813837
[7]   Clinical mammography at the SYRMEP beam line [J].
Castelli, E. ;
Arfelli, F. ;
Dreossi, D. ;
Longo, R. ;
Rokvic, T. ;
Cova, M. A. ;
Quaia, E. ;
Tonutti, M. ;
Zanconati, F. ;
Abrami, A. ;
Chenda, V. ;
Menk, R. H. ;
Quai, E. ;
Tromba, G. ;
Bregant, P. ;
de Guarrini, F. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01) :237-240
[8]   Mammography with Synchrotron Radiation: First Clinical Experience with Phase-Detection Technique [J].
Castelli, Edoardo ;
Tonutti, Maura ;
Arfelli, Fulvia ;
Longo, Renata ;
Quaia, Emilio ;
Rigon, Luigi ;
Sanabor, Daniela ;
Zanconati, Fabrizio ;
Dreossi, Diego ;
Abrami, Alessando ;
Quai, Elisa ;
Bregant, Paola ;
Casarin, Katia ;
Chenda, Valentina ;
Menk, Ralf Hendrik ;
Rokvic, Tatjana ;
Vascotto, Alessandro ;
Tromba, Giuliana ;
Cova, Maria Assunta .
RADIOLOGY, 2011, 259 (03) :684-694
[9]   Hard X-ray phase imaging and tomography using a grating interferometer [J].
David, C. ;
Weitkamp, T. ;
Pfeiffer, F. ;
Diaz, A. ;
Bruder, J. ;
Rohbeck, T. ;
Groso, A. ;
Bunk, O. ;
Stampanoni, M. ;
Cloetens, P. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (6-7) :626-630
[10]   Characterization of Pixirad-1 photon counting detector for X-ray imaging [J].
Delogu, P. ;
Oliva, P. ;
Bellazzini, R. ;
Brez, A. ;
de Ruvo, P. L. ;
Minuti, M. ;
Pinchera, M. ;
Spandre, G. ;
Vincenzi, A. .
JOURNAL OF INSTRUMENTATION, 2016, 11