共 50 条
Polydiphenylamine-dodecyl sulfate films for the simultaneous amperometric determination of electroinactive anions and cations in ion-exclusion cation-exchange chromatography
被引:4
|作者:
Xu, Q
Xu, C
Wang, YP
Zhang, W
Jin, LT
[1
]
Tanaka, K
Haraguchi, H
Itoh, A
机构:
[1] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
[2] Natl Ind Res Inst Nagoya, Kita Ku, Nagoya, Aichi 462, Japan
[3] Nagoya Univ, Sch Engn, Dept Appl Chem, Chikusa Ku, Nagoya, Aichi 4648603, Japan
来源:
关键词:
D O I:
10.1007/s002160000591
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
An amperometric detector with two working electrodes both modified with polydiphenylamine-dodecyl sulfate (PDPA-DS) was successfully used for the simultaneous determination of electroinactive anions (SO42-, Cl-, NO3-) and cations (Na+, NH4+ and K+) in single-column ion-exclusion cation-exchange chromatography (IEC-GEC). The PDPA-DS chemical modified electrode (CME) was based on the incorporation of dodecyl sulfate (DS) into PDPA by electropolymerization of diphenylamine in the presence of sodium dodecyl sulfate. The electrochemical responses against the anions and cations at the PDPA-DS CME in differential pulse voltammetry were studied. A set of well-defined peaks of electroinactive anions and cations were obtained. The anions and cations were detected conveniently and reproducibly in a linear concentration range 0.01-5.0 mmol/L and their detection limits were in the range 5-9 mu mol/L at a signal-to-noise ratio of 3 (S/N = 3). The proposed method was quick, sensitive and simple and was successfully applied to the analysis of lake water samples. The working electrode was stable over one week period of operation with no evidence of chemical and mechanical deterioration.
引用
收藏
页码:791 / 796
页数:6
相关论文