Numerical Study of Convection and Radiation Heat Transfer in Pipe Cable

被引:19
作者
Fu, Chen-Zhao [1 ]
Si, Wen-Rong [1 ]
Quan, Lei [2 ]
Yang, Jian [2 ]
机构
[1] State Grid Shanghai Elect Power Res Inst, Shanghai 200437, Peoples R China
[2] Xi An Jiao Tong Univ, Key Lab Thermofliud Sci & Engn, Xian 710049, Shaanxi, Peoples R China
关键词
COUPLED CONDUCTION-CONVECTION; THERMAL-ANALYSIS; OPTIMIZATION; DISSIPATION; SIMULATION; BACKFILL; SYSTEM;
D O I
10.1155/2018/5475136
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Pipe cable is considered as an important form for underground transmission line. The maximum electrical current (ampacity) of power cable system mostly depends on the cable conductor temperature. Therefore, accurate calculation of temperature distribution in the power cable system is quite important to extract the cable ampacity. In the present paper, the fluid flow and heat transfer characteristics in the pipe cable with alternating current were numerically studied by using commercial code COMSOL MULTIPHYSICS based on finite element method (FEM). The cable core loss and eddy current loss in the cable were coupled for the heat transfer simulation, and the difference of heat transfer performances with pure natural convection model and radiation-convection model was compared and analysed in detail. Meanwhile, for the radiation-convection model, the effects caused by radiant emissivity of cable surface and pipe inner surface, as well as the cable location in the pipe, were also discussed. Firstly, it is revealed that the radiation and natural convection heat flux on the cable surface would be of the same order of magnitude, and the radiation heat transfer on the cable surface should not be ignored. Otherwise, the cable ampacity would be underestimated. Secondly, it is found that the overall heat transfer rate on the cable surface increases as the cable surface emissivity increases, and this is more remarkable to the upper cable. While the effect caused by the radiant emissivity on the pipe inner surface would be relatively small. Furthermore, it is demonstrated that, as cable location in the pipe falls, the natural convection heat transfer would be enhanced. These results would be meaningful for the ampacity prediction and optimum design for the pipe cable.
引用
收藏
页数:12
相关论文
共 23 条
[1]   PSO of power cable performance in complex surroundings [J].
Al-Saud, Mamdooh S. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (10) :2452-2461
[2]   Ampacity Calculations for Cables in Shallow Troughs [J].
Anders, George J. ;
Coates, Mark ;
Chaaban, Mohamed .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :2064-2072
[3]  
[Anonymous], 1994, 8351994 IEEE
[4]   Mock-Up Study of the Effect of Wall Distance on the Thermal Rating of Power Cables in Ventilated Tunnels [J].
Boukrouche, Fahd ;
Moreau, Christophe ;
Pelle, Julien ;
Beaubert, Francois ;
Harmand, Souad ;
Moreau, Olivier .
IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (06) :2453-2461
[5]   On contact point modifications for forced convective heat transfer analysis in a structured packed bed of spheres [J].
Bu, S. S. ;
Yang, J. ;
Zhou, M. ;
Li, S. Y. ;
Wang, Q. W. ;
Guo, Z. X. .
NUCLEAR ENGINEERING AND DESIGN, 2014, 270 :21-33
[6]  
Dai D, 2014, 2014 ELECTRICAL INSULATION CONFERENCE (EIC), P303, DOI 10.1109/EIC.2014.6869397
[7]  
Hu M. L., 2015, CALCULATION THERMAL
[8]   Extensions to the finite element method for thermal analysis of underground cable systems [J].
Hwang, CC ;
Jiang, YH .
ELECTRIC POWER SYSTEMS RESEARCH, 2003, 64 (02) :159-164
[9]  
IEC, 1995, 6028721 IEC
[10]   Numerical simulation of coupled heat, liquid water and water vapor in soils for heat dissipation of underground electrical power cables [J].
Kroener, Eva ;
Vallati, Andrea ;
Bittelli, Marco .
APPLIED THERMAL ENGINEERING, 2014, 70 (01) :510-523