Evaluation of the Effect of Body Position on Intraocular Pressure Measured with Rebound Tonometer

被引:11
作者
Mayali, Huseyin [1 ]
Tekin, Beyza [1 ]
Kayikcioglu, Ozcan Rasim [1 ]
Kurt, Emin [1 ]
Ilker, Suleyman Sami [1 ]
机构
[1] Manisa Celal Bayar Univ, Fac Med, Dept Ophthalmol, Manisa, Turkey
来源
TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY | 2019年 / 49卷 / 01期
关键词
Intraocular pressure; body position; tonometer; EPISCLERAL VENOUS-PRESSURE; CENTRAL CORNEAL THICKNESS; POSTURAL RESPONSE; HEALTHY-SUBJECTS; GLAUCOMA; PATTERN; HEAD;
D O I
10.4274/tjo.galenos.2018.90359
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: It is important to determine variables that influence intraocular pressure (IOP) measurement. This study aimed to evaluate the effect of body position on IOP. Materials and Methods: The study included 52 right eyes of 52 patients who presented to the ophthalmology department of our hospital and had no ocular disease except refractive errors. IOP was measured with an Icare PRO tonometer while patients were in sitting, standing, and supine positions, with intervals of 10 minutes between the positions. Correlations between the results were evaluated using Spearman's correlation analysis and Wilcoxon tests. Results: Thirty-six of the 52 patients were female, 16 were male. Mean age was 31.65 +/- 6.30 (23-47) years. Mean IOP values in the sitting, standing, and lying positions were 17.76 +/- 3.41 (12.70-25.60) mmHg, 17.10 +/- 3.27 (11.50-25.20) mmHg, and 18.46 +/- 4.67 (10.50-29.40) mmHg, respectively. There were no statistically significant differences between measurements taken in the different positions (p=0.112, p=0.472, p=0.071). We observed that there was no relationship between age and body position (p>0.45, p>0.79, p>0.77) or between gender and position (p>0.59, p>0.69, p>0.54). Conclusion: Gender and age had no effect on IOP measured in different body positions. There were also no significant differences between IOP values measured in the different positions. Therefore, we believe the portable Icare PRO tonometer can be used for patients who are confined to bed and will provide IOP measurements that are concordant with values obtained while sitting.
引用
收藏
页码:6 / 9
页数:4
相关论文
共 30 条
[1]  
Asrani S, 2000, J GLAUCOMA, V9, P134
[2]   Measurement of the difference in intraocular pressure between the sitting and lying body positions in healthy subjects: direct comparison of the Icare Pro with the Goldmann applanation tonometer, Pneumatonometer and Tonopen XL [J].
Barkana, Yaniv ;
Gutfreund, Shay .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07) :608-614
[3]   Postural Change in Intraocular Pressure: A Comparison of Measurement With a Goldmann Tonometer, Tonopen XL, Pneumatonometer, and HA-2 [J].
Barkana, Yaniv .
JOURNAL OF GLAUCOMA, 2014, 23 (01) :E23-E28
[4]   Diurnal variation of episcleral venous pressure in healthy patients:: A pilot study [J].
Blondeau, P ;
Tétrault, JP ;
Papamarkakis, C .
JOURNAL OF GLAUCOMA, 2001, 10 (01) :18-24
[5]  
CARLSON KH, 1987, INVEST OPHTH VIS SCI, V28, P1346
[6]   Changes in intraocular pressure during prolonged (7-day) head-down tilt bedrest [J].
Chiquet, C ;
Custaud, MA ;
Le Traon, AP ;
Millet, C ;
Gharib, T ;
Denis, P .
JOURNAL OF GLAUCOMA, 2003, 12 (03) :204-208
[7]   INTRAOCULAR AND EPISCLERAL VENOUS-PRESSURE INCREASE DURING INVERTED POSTURE [J].
FRIBERG, TR ;
SANBORN, G ;
WEINREB, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1987, 103 (04) :523-526
[8]   Effect of Trabeculectomy on Intraocular Pressure Fluctuation With Postural Change in Eyes With Open-angle Glaucoma [J].
Hirooka, Kazuyuki ;
Takenaka, Hirokazu ;
Baba, Tetsuya ;
Takagishi, Mai ;
Mizote, Masanori ;
Shiraga, Fumio .
JOURNAL OF GLAUCOMA, 2009, 18 (09) :689-691
[9]   RAPID PNEUMATIC AND MACKAY-MARG APPLANATION TONOMETRY TO EVALUATE POSTURAL EFFECT ON INTRAOCULAR-PRESSURE [J].
JAIN, MR ;
MARMION, VJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1976, 60 (10) :687-693
[10]   Postural Response of Intraocular Pressure and Visual Field Damage in Patients With Untreated Normal-tension Glaucoma [J].
Kiuchi, Takahiro ;
Motoyama, Yuta ;
Oshika, Tetsuro .
JOURNAL OF GLAUCOMA, 2010, 19 (03) :191-193