The impact of Nd: YAG laser posterior capsulotomy by the use of "the circular pattern with vitreous strand cut" technique on anterior chamber parameters

被引:9
作者
El-Haddad, Nermien Salah El-Dien Mohammed [1 ]
机构
[1] Al Azhar Univ, Fac Med, Cairo, Egypt
关键词
Nd:YAG laser; Posterior capsulotomy; Circular pattern; Vitreous strand cut technique; INTRAOCULAR-PRESSURE; NEODYMIUM; REFRACTION; DEPTH; OPACIFICATION;
D O I
10.1007/s10103-018-2602-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study included 42 eyes of 33 pseudophakic patients with visually significant PCO after uncomplicated cataract surgery. Exclusion criteria were complications related to cataract surgery, corneal pathology, pseudoexfoliation, glaucoma, uveitis, previous ocular surgery or trauma, and posterior segment pathology. All patients underwent routine ophthalmic examinations. The AS-OCT measurements were performed using NIDEK RS-3000 Lite retinal scan with anterior segment module. The anterior chamber depth (ACD) was measured by Monitor A&B Scan biometer. Nd: YAG laser posterior capsulotomy was done in a single session by the circular pattern with rupture of vitreous strands. Anterior chamber depth (ACD), central corneal thickness (CCT), and intraocular pressure (IOP) were measured. Anterior chamber angle (ACA), angle opening distances (AOD) at 500 mm (AOD500), AOD at 750 mm (AOD750), trabecular-iris space area at 500 (TISA 500), and TISA at 750 (TISA 750) were measured both nasally and temporally. The mean patient age was 55.56 +/- 6.33 years. There were non-significant changes in IOP, ACD, and CCT with P values 0.395, 0.153, and 0.541, respectively. ACA, AOD500, AOD750, TISA 500, and TISA 750 highly significantly increased with P value < 0.001 for all. Nd: YAG laser posterior capsulotomy with the circular pattern with vitreous strand cut technique is a safe technique for laser posterior capsulotomy.
引用
收藏
页码:353 / 357
页数:5
相关论文
共 21 条
[1]   The Effects of Nd:YAG Laser Posterior Capsulotomy on Macular Thickness, Intraocular Pressure, and Visual Acuity [J].
Ari, Seyhmus ;
Cingu, Abdullah Kursat ;
Sahin, Alparslan ;
Cinar, Yasin ;
Caca, Ihsan .
OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (05) :395-400
[2]   Anterior Segment Optical Coherence Tomography Measurement After Neodymium-Yttrium-Aluminum-Garnet Laser Capsulotomy [J].
Eliacik, Mustafa ;
Bayramlar, Huseyin ;
Erdur, Sevil Karaman ;
Demirci, Goktug ;
Gulkilik, Gokhan .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (05) :994-998
[3]  
Erdur SK, 2015, EYE CONTACT LENS, P1
[4]   Changes in intraocular lens position after neodymium:YAG capsulotomy [J].
Findl, O ;
Drexler, W ;
Menapace, R ;
Georgopoulos, M ;
Rainer, G ;
Hitzenberger, CK ;
Fercher, AF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (05) :659-662
[5]  
Ge J, 2000, ARCH OPHTHALMOL-CHIC, V118, P1334
[6]   Influence of laser posterior capsulotomy on anterior chamber depth, refraction, and intraocular pressure [J].
Hu, CY ;
Woung, LC ;
Wang, MC ;
Jian, JH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08) :1183-1189
[7]   The Effect of ND:YAG Laser Posterior Capsulotomy Size on Refraction, Intraocular Pressure, and Macular Thickness [J].
Karahan, Eyyup ;
Tuncer, Ibrahim ;
Zengin, Mehmet Ozgur .
JOURNAL OF OPHTHALMOLOGY, 2014, 2014
[8]  
Keates R H, 1984, J Am Intraocul Implant Soc, V10, P164
[9]   A new technique for Nd:YAG laser posterior capsulotomy [J].
Min, Jung Kee ;
An, Jae Hwan ;
Yim, Jin Ho .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (02) :345-349
[10]   Refraction, intraocular pressure and anterior chamber depth changes after Nd:YAG laser treatment for posterior capsular opacification in pseudophakic eyes [J].
Ozkurt, Yelda Buyru ;
Sengor, Tomris ;
Evciman, Tufan ;
Haboglu, Melih .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (05) :412-415