Distal plate placement for distal radius fractures limits wrist motion

被引:1
|
作者
Komura, Shingo [1 ]
Tanahashi, Hiroyuki [1 ]
Yamada, Yoshihisa [1 ]
Yokoi, Tatsuo [1 ]
Nonomura, Hidehiko [1 ]
Suzuki, Yasushi [2 ]
机构
[1] Gifu Prefectural Gen Med Ctr, Dept Orthopaed Surg, Gifu 5008717, Japan
[2] Gifu Prefectural Gero Hot Spring Hosp, Dept Orthopaed Surg, Gifu, Japan
关键词
Distal radius fracture; Volar locking plate; Watershed line; Range of motion; Flexor tendons; Hardware removal; LOCKING-PLATE; FIXATION; COMPLICATIONS;
D O I
10.1007/s00590-011-0809-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To investigate the influence of distal plate placement for distal radius fractures on risk of flexor tendon complications and wrist motion by performing hardware removal. Materials and methods Fourteen patients treated with a Synthes 2.4 mm juxta-articular LCP Distal Radius Plate underwent hardware removal at >= 6 months postoperatively when improvement of range of motion and grip strength were obtained. Location of plate placement, condition of the flexor tendons, range of motion, grip strength, and postoperative complications were evaluated. Results The average minimum distance between the plate and joint line was 2.0 mm (range, 0.4-4.5 mm), and average distance at the base of the styloid process was 7.5 mm (range, 4.2-9.6 mm). All plates were located distal to the watershed line. Pathological conditions of flexor tendons were observed in 3 patients-adhesion of flexor pollicis longus in 1 and flexor tendon synovitis in 2-however, there were no cases of abrasion or rupture. The average active wrist flexion improved from 53.6 degrees to 61.1 degrees, extension from 67.5 degrees to 70.7 degrees, and the flexion-extension arc of motion improved from 121.1 degrees to 131.8 degrees. The flexion and flexion-extension arc were significantly improved (P = 0.0003 and P = 0.007, respectively). The average grip strength increased from 18.5 to 19.4 kg (not significant). Temporary median nerve disturbance was observed in 1 patient as a postoperative complication. Conclusions Removal of juxta-articular LCP Distal Radius Plate improved wrist motion. Plates located distal to the watershed line may increase the risk of flexor tendon complications and limit wrist motion.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 50 条
  • [41] Predicting a Safe Screw Length for Volar Plate Fixation of Distal Radius Fractures: Lunate Depth as a Marker for Distal Radius Depth
    Ljungquist, Karin L.
    Agnew, Sonya P.
    Huang, Jerry I.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (05): : 940 - 944
  • [42] Volar Radioscapholunate Arthrodesis and Distal Scaphoidectomy After Malunited Distal Radius Fractures
    Quadlbauer, Stefan
    Leixnering, Martin
    Jurkowitsch, Josef
    Hausner, Thomas
    Pezzei, Christoph
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (09): : 754.e1 - 754.e8
  • [43] The palmar fixed angle plate in distal radius fractures - advantages and disadvantages
    Schmelzer-Schmied, N.
    Martini, A. K.
    Jung, M.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2007, 2 (03): : 150 - 155
  • [44] Treatment of anterior rim fractures of the distal radius with an anterior rim plate: A retrospective study
    Chen, Kuan-Po
    Chen, I-Chien
    Wu, Chin-Hsien
    Tseng, Tzu-Ming
    Ma, Ching-Hou
    Tu, Yuan-Kun
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2025,
  • [45] Temporary spanning plate wrist fixation of complex distal radius fractures: a systematic review of 353 patients
    Beeres, Frank J. P.
    van de Wall, Bryan J. M.
    Hug, Urs
    Schep, Niels W. L.
    Babst, Reto
    Link, Bjorn-Christian
    Migliorini, Filippo
    Knobe, Matthias
    Liechti, Remy
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (03) : 1649 - 1662
  • [46] Computed Tomography and Pathobiomechanical-Based Treatment of Volar Distal Radius Fractures
    Hintringer, Wolfgang
    Rosenauer, Rudolf
    Quadlbauer, Stefan
    JOURNAL OF WRIST SURGERY, 2022, 11 (03) : 203 - 213
  • [47] Results of volar locking plating for unstable distal radius fractures
    Sugun, Tahir Sadik
    Gurbuz, Yusuf
    Ozaksar, Kemal
    Toros, Tulgar
    Kayalar, Murat
    Bal, Emin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (01) : 22 - 25
  • [48] Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
    Shinohara, Takaaki
    Hirata, Hitoshi
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2017, 79 (04): : 551 - 557
  • [49] Temporary spanning plate wrist fixation of complex distal radius fractures: a systematic review of 353 patients
    Frank J. P. Beeres
    Bryan J. M. van de Wall
    Urs Hug
    Niels W. L. Schep
    Reto Babst
    Björn-Christian Link
    Filippo Migliorini
    Matthias Knobe
    Rémy Liechti
    European Journal of Trauma and Emergency Surgery, 2022, 48 : 1649 - 1662
  • [50] Palmar Displacement in Distal Radius Fractures following Extension Injuries of the Wrist
    Selle, Christopher
    Latz, David
    Friesen, Denis
    Schaedel-Hoepfne, Michael
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2025, 57 (01) : 62 - 70