Distal plate placement for distal radius fractures limits wrist motion

被引:1
|
作者
Komura, Shingo [1 ]
Tanahashi, Hiroyuki [1 ]
Yamada, Yoshihisa [1 ]
Yokoi, Tatsuo [1 ]
Nonomura, Hidehiko [1 ]
Suzuki, Yasushi [2 ]
机构
[1] Gifu Prefectural Gen Med Ctr, Dept Orthopaed Surg, Gifu 5008717, Japan
[2] Gifu Prefectural Gero Hot Spring Hosp, Dept Orthopaed Surg, Gifu, Japan
关键词
Distal radius fracture; Volar locking plate; Watershed line; Range of motion; Flexor tendons; Hardware removal; LOCKING-PLATE; FIXATION; COMPLICATIONS;
D O I
10.1007/s00590-011-0809-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To investigate the influence of distal plate placement for distal radius fractures on risk of flexor tendon complications and wrist motion by performing hardware removal. Materials and methods Fourteen patients treated with a Synthes 2.4 mm juxta-articular LCP Distal Radius Plate underwent hardware removal at >= 6 months postoperatively when improvement of range of motion and grip strength were obtained. Location of plate placement, condition of the flexor tendons, range of motion, grip strength, and postoperative complications were evaluated. Results The average minimum distance between the plate and joint line was 2.0 mm (range, 0.4-4.5 mm), and average distance at the base of the styloid process was 7.5 mm (range, 4.2-9.6 mm). All plates were located distal to the watershed line. Pathological conditions of flexor tendons were observed in 3 patients-adhesion of flexor pollicis longus in 1 and flexor tendon synovitis in 2-however, there were no cases of abrasion or rupture. The average active wrist flexion improved from 53.6 degrees to 61.1 degrees, extension from 67.5 degrees to 70.7 degrees, and the flexion-extension arc of motion improved from 121.1 degrees to 131.8 degrees. The flexion and flexion-extension arc were significantly improved (P = 0.0003 and P = 0.007, respectively). The average grip strength increased from 18.5 to 19.4 kg (not significant). Temporary median nerve disturbance was observed in 1 patient as a postoperative complication. Conclusions Removal of juxta-articular LCP Distal Radius Plate improved wrist motion. Plates located distal to the watershed line may increase the risk of flexor tendon complications and limit wrist motion.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 50 条
  • [21] Three-dimensional deformity analysis of malunited distal radius fractures and their influence on wrist and forearm motion
    Miyake, J.
    Murase, T.
    Yamanaka, Y.
    Moritomo, H.
    Sugamoto, K.
    Yoshikawa, H.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (06) : 506 - 512
  • [22] Dorsal Bridge Plate for Distal Radius Fractures: A Systematic Review
    Fares, Austin B.
    Childs, Benjamin R.
    Polmear, Michael M.
    Clark, DesRaj M.
    Nesti, Leon J.
    Dunn, John C.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2021, 46 (07): : 627.e1 - 627.e8
  • [23] Avoiding Complications in Distal Radius Fractures
    Bates, Taylor J.
    Plucknette, Benjamin F.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 : S27 - S32
  • [24] Breakage of volar locking plate system for distal radius fractures
    Kawanishi, Syohei
    Gato, Uasushi
    Nakai, Tsuyoshi
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (S 1): : 71 - 77
  • [25] Tronco-conical locking plate in distal radius fractures
    Maiello, Alessio
    Rivera, Fabrizio
    Maniscalco, Pietro
    Colombo, Massimiliano
    Di Stefano, Giovanni
    Quattrini, Fabrizio
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 : S19 - S22
  • [26] Dynamic splinting in wrist extension following distal radius fractures
    Stacey H Berner
    F Buck Willis
    Journal of Orthopaedic Surgery and Research, 5
  • [27] Complications of Distal Radius Fractures
    Turner, Robert G.
    Faber, Kenneth J.
    Athwal, George S.
    HAND CLINICS, 2010, 26 (01) : 85 - 96
  • [28] Fixation of Distal Ulna Fractures Associated with Distal Radius Fractures Using Intrafocal Pin Plate
    Nemeth, Nicole
    Bindra, Randy R.
    JOURNAL OF WRIST SURGERY, 2014, 3 (01) : 55 - 59
  • [29] Minimally invasive plate osteosynthesis for distal radius fractures
    Xu-ming Wei
    Zhen-zhong Sun
    Yong-jun Rui
    Xiao-Jun Song
    Indian Journal of Orthopaedics, 2014, 48 : 20 - 24
  • [30] Dorsal nail plate fixation of distal radius fractures
    Rampoldi, Michele
    Marsico, Aldo
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (04): : 472 - 478