摘要
Purpose To investigate the influence of distal plate placement for distal radius fractures on risk of flexor tendon complications and wrist motion by performing hardware removal. Materials and methods Fourteen patients treated with a Synthes 2.4 mm juxta-articular LCP Distal Radius Plate underwent hardware removal at >= 6 months postoperatively when improvement of range of motion and grip strength were obtained. Location of plate placement, condition of the flexor tendons, range of motion, grip strength, and postoperative complications were evaluated. Results The average minimum distance between the plate and joint line was 2.0 mm (range, 0.4-4.5 mm), and average distance at the base of the styloid process was 7.5 mm (range, 4.2-9.6 mm). All plates were located distal to the watershed line. Pathological conditions of flexor tendons were observed in 3 patients-adhesion of flexor pollicis longus in 1 and flexor tendon synovitis in 2-however, there were no cases of abrasion or rupture. The average active wrist flexion improved from 53.6 degrees to 61.1 degrees, extension from 67.5 degrees to 70.7 degrees, and the flexion-extension arc of motion improved from 121.1 degrees to 131.8 degrees. The flexion and flexion-extension arc were significantly improved (P = 0.0003 and P = 0.007, respectively). The average grip strength increased from 18.5 to 19.4 kg (not significant). Temporary median nerve disturbance was observed in 1 patient as a postoperative complication. Conclusions Removal of juxta-articular LCP Distal Radius Plate improved wrist motion. Plates located distal to the watershed line may increase the risk of flexor tendon complications and limit wrist motion.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 50 条
  • [1] Distal plate placement for distal radius fractures limits wrist motion
    Shingo Komura
    Hiroyuki Tanahashi
    Yoshihisa Yamada
    Tatsuo Yokoi
    Hidehiko Nonomura
    Yasushi Suzuki
    European Journal of Orthopaedic Surgery & Traumatology, 2012, 22 : 29 - 34
  • [2] Recovery of Wrist Function after Volar Locking Plate Fixation for Distal Radius Fractures
    Takeuchi, Naohide
    Hotokezaka, Shunsuke
    Okada, Takamitsu
    Yuge, Hidehiko
    Mae, Takao
    Iwamoto, Yukihide
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (02) : 199 - 206
  • [3] A Prospective Observational Assessment of Unicortical Distal Screw Placement During Volar Plate Fixation of Distal Radius Fractures
    Dardas, Agnes Z.
    Goldfarb, Charles A.
    Boyer, Martin I.
    Osei, Daniel A.
    Dy, Christopher J.
    Calfee, Ryan P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (05): : 448 - 454
  • [4] Feasibility study of juxta-articular-type volar distal radius plate (ARIX Wrist System) for surgically treating marginal distal radius fractures
    Lee, Byoung Gu
    Lee, Seung Hoo
    HELIYON, 2023, 9 (04)
  • [5] The volar locking plate for extension fractures of the distal radius
    Pillukat, T.
    Fuhrmann, R.
    Windolf, J.
    van Schoonhoven, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (01): : 47 - 63
  • [6] Minimally invasive plate osteosynthesis for distal radius fractures
    Wei, Xu-ming
    Sun, Zhen-zhong
    Rui, Yong-jun
    Song, Xiao-Jun
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (01) : 20 - 24
  • [7] Residual wrist pain after volar locking plate fixation of distal radius fractures
    Kurimoto, Shigeru
    Tatebe, Masahiro
    Shinohara, Takaaki
    Arai, Tetsuya
    Hirata, Hitoshi
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (05): : 603 - 610
  • [8] Limits of palmar locking-plate osteosynthesis of unstable distal radius fractures
    Arora, R.
    Lutz, M.
    Zimmermann, R.
    Krappinger, D.
    Gabl, M.
    Pechlaner, S.
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2007, 39 (01) : 34 - 41
  • [9] Volar plate fixation of distal radius fractures
    Demirbas, Emrah Riza
    Ugras, Ali Akin
    Kaya, Ibrahim
    Sungur, Ibrahim
    Kural, Cemal
    Cetinus, Ercan
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2012, 18 (02): : 162 - 166
  • [10] Wrist arthroscopy in the management of distal radius fractures
    Shkolnikova, Julia
    Harvey, Jason
    ANNALS OF JOINT, 2018, 3 (09):