capillary electrophoresis;
electric field gradient focusing;
microfluidics;
proteins;
D O I:
10.1002/elps.200700652
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Electric field gradient focusing (EFGF) methods have received increased attention in recent years, with potential applications demonstrated by several research groups. In order to move EFGF from the research stage to routine use in application areas, a more detailed understanding of practical aspects of device performance is required. Useful theoretical models for EFGF are available but have not been verified through systematic checks under a variety of conditions. In this paper, we compare modeled and experimental results for an EFGF device with the goal of optimizing the time sequence of voltages applied to the device for maximum resolution of analytes with close electrophoretic mobilities. Measured peak profiles depend strongly on the sequence of voltages applied to the device. We investigate the characteristic behavior of the elution profile under various voltage programs. Rapid voltage drops lead to fast elution of closely spaced protein peaks with narrow widths, whereas a carefully designed voltage program can be used to increase the separation between analytes and achieve higher resolution. Simulated and experimental results demonstrate that the behavior of analyte diffusion at an electric field singularity associated with the transition from the EFGF device to elution capillary can be used to separate analyte peaks which may not be resolved within the EFGF device itself, thereby increasing the achievable resolution of the EFGF technique.
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst WIMS2, Ann Arbor, MI 48109 USA
Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USAUniv Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Li, Maxwell Wei-Hao
Zhu, Hongbo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst WIMS2, Ann Arbor, MI 48109 USAUniv Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Zhu, Hongbo
Zhou, Menglian
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst WIMS2, Ann Arbor, MI 48109 USAUniv Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Zhou, Menglian
She, Jinyan
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst WIMS2, Ann Arbor, MI 48109 USAUniv Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
She, Jinyan
Li, Ziqi
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Tianjin Univ, Sch Precis Instruments & Optoelect Engn, Tianjin, Peoples R ChinaUniv Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Li, Ziqi
Kurabayashi, Katsuo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst WIMS2, Ann Arbor, MI 48109 USA
Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USAUniv Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Kurabayashi, Katsuo
Fan, Xudong
论文数: 0引用数: 0
h-index: 0
机构:
Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst WIMS2, Ann Arbor, MI 48109 USAUniv Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA