Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair

被引:164
作者
Frank, Joshua B. [1 ]
ElAttrache, Neal S. [1 ]
Dines, Joshua S. [1 ]
Blackburn, Allie [2 ]
Crues, John [2 ]
Tibone, James E. [1 ]
机构
[1] Kerlan Jobe Orthopaed Clin, Los Angeles, CA USA
[2] RadNet Radiol, Los Angeles, CA USA
关键词
arthroscopic repair; rotator cuff; double-row; transosseous-equivalent;
D O I
10.1177/0363546507313574
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Successful healing after arthroscopic rotator cuff repair remains a challenge. Earlier studies have shown a relatively high rate of failure. New surgical techniques may improve healing potential. The purpose of this study was to provide an objective evaluation of repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair. Hypothesis: Rotator cuff tears repaired using the transosseous-equivalent suture-bridge technique will show a higher intact rate on postoperative magnetic resonance imaging (MRI) evaluation. Study Design: Case series; Level of evidence, 4. Methods: The first 25 patients who underwent arthroscopic rotator cuff repair using the transosseous-equivalent suture-bridge technique underwent MRI evaluation of the postoperative shoulder. Minimum follow-up was 1 year. Demographic, clinical, and surgical factors, including tear size, were evaluated. Results: Postoperative MRI demonstrated intact surgical repair sites in 22 of 25 patients (88%). Tears limited to the supraspinatus tendon were intact in 16 of 18 patients (89%). Tears of the supraspinatus involving part or all of the infraspinatus showed an 86% intact rate (6 of 7 patients). Of these tears, 3 were considered massive (complete 2-tendon or greater). These demonstrated an intact cuff on MRI. Conclusions: The transosseous-equivalent suture-bridge technique demonstrates a high healing rate on imaging studies at 1 year. Of the first 25 patients repaired with the technique, 88% had an intact rotator cuff repair on MRI evaluation. This indicates excellent cuff healing, as judged by the intact repair sites, compared with most standard arthroscopic rotator cuff repair series. In this early report of the technique, a persistent tear could not be correlated with age or initial tear size; however, this may be due to the relatively small sample size.
引用
收藏
页码:1496 / 1503
页数:8
相关论文
共 28 条
  • [1] Outcome and structural integrity after arthroscopic rotator cuff repair using 2 rows of fixation - Minimum 2-year follow-up
    Anderson, Kyle
    Boothby, Michael
    Aschenbrener, Daniel
    van Holsbeeck, Marnix
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (12) : 1899 - 1905
  • [2] Cuff integrity after arthroscopic versus open rotator cuff repair: A prospective study
    Bishop, Julie
    Klepps, Steven
    Lo, Ian K.
    Bird, Justin
    Gladstone, James N.
    Flatow, Evan L.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (03) : 290 - 299
  • [3] Arthroscopic repair of full-thickness tears of the supraspinatus: Does the tendon really heal?
    Boileau, P
    Brassart, N
    Watkinson, DJ
    Carles, M
    Hatzidakis, AM
    Krishnan, SG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (06) : 1229 - 1240
  • [4] Evaluation of residual rotator cuff defects after in vivo single- versus double-row rotator cuff repairs
    Brady, Paul C.
    Arrigoni, Paolo
    Burkhart, Stephen S.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (10) : 1070 - 1075
  • [5] Can a double-row anchorage technique improve tendon healing in Arthroscopic rotator cuff repair? A prospective, nonrandomized, comparative study of double-row and single-row anchorage techniques with computed tomographic arthrography tendon healing assessment
    Charousset, Christophe
    Grimberg, Jean
    Duranthon, Louis Denis
    Bellaiche, Laurance
    Petrover, David
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (08) : 1247 - 1253
  • [6] Cuff integrity after arthroscopic rotator cuff repair: Correlation with clinical results in 576 cases
    Flurin, Pierre-Henri
    Landreau, Philippe
    Gregory, Thomas
    Boileau, Pascal
    Lafosse, Laurent
    Guillo, Stephane
    Kempf, Jean-Francois
    Toussaint, Bruno
    Courage, Olivier
    Brassart, Nicolas
    Laprelle, Erick
    Charousset, Christophe
    Steyer, Alexandre
    Wolf, Eugene M.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (04) : 340 - 346
  • [7] Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears - A randomized controlled trial
    Franceschi, Francesco
    Ruzzini, Laura
    Longo, Umile Giuseppe
    Martina, Francesca Maria
    Zobel, Bruno Beornonte
    Maffulli, Nicola
    Denaro, Vincenzo
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (08) : 1254 - 1260
  • [8] Magnetic resonance imaging for evaluation of failed repairs of the rotator cuff - Relationship to operative findings
    Gaenslen, ES
    Satterlee, CC
    Hinson, GW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) : 1391 - 1396
  • [9] The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears
    Galatz, LM
    Ball, CM
    Teefey, SA
    Middleton, WD
    Yamaguchi, K
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (02) : 219 - 224
  • [10] GAZIELLY DF, 1994, CLIN ORTHOP RELAT R, P43