Impact of the limitations of state-of-the-art micro-fabrication processes on the performance of pillar array columns for liquid chromatography

被引:27
作者
de Beeck, Jeff Op [1 ]
De Malsche, Wim [1 ]
Tezcan, Deniz S. [2 ]
De Moor, Piet [2 ]
Desmet, Gert [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
[2] IMEC, B-3001 Louvain, Belgium
关键词
Microfabrication; Chromatographic support structures; Miniaturization; Pillar array columns; MONOLITHIC SUPPORT STRUCTURES; PARTICLE-SIZE DISTRIBUTION; HIGH-ASPECT-RATIO; DRIVEN CHROMATOGRAPHY; SEPARATION; DISPERSION; OPTIMIZATION; CHIP; REDUCTION; CHANNELS;
D O I
10.1016/j.chroma.2012.03.054
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report on the practical limitations of the current state-of-the-art in micro-fabrication technology to produce the small pillar sizes that are needed to obtain high efficiency pillar array columns. For this purpose, nine channels with a different pillar diameter, ranging from 5 to 0.5 mu m were fabricated using state-of the-art deep-UV lithography and deep reactive ion etching (DRIE) etching technology. The obtained results strongly deviated from the theoretically expected trend, wherein the minimal plate height (H-min) would reduce linearly with the pillar diameter. The minimal plate height decreases from 1.7 to 1.2 mu m when going from 4.80 to 3.81 mu m diameter pillars, but as the dimensions are further reduced, the minimal plate heights rise again to values around 2 mu m. The smallest pillar diameter even produced the worst minimal plate height (4 mu m). An in-depth scanning electron microscopy (SEM) inspection of the different channels clearly reveals that these findings can be attributed to the micro-fabrication limitations that are inevitably encountered when exploring the limits of deep-UV lithography and DRIE etching processes. When the target dimensions of the design approach the etching resolution limits, the band broadening increases in a strongly non-linear way with the decreased pillar dimensions. This highly non-linear relationship can be understood from first principles: when the machining error is of the order of 100-200 nm and when the target design size for the inter-pillar distance is of the order of 250 nm, this inevitably leads to pores that will range in size between 50 and 450 nm that we want to highlight with our paper highly non-linear relationship. This highly non-linear relationship can be understood from first principles: when the machining error is of the order of 100-200 nm and when the target design size for the inter-pillar distance is of the order of 250 nm, this inevitably leads to pores that will range in size between 50 and 450 nm. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 48
页数:14
相关论文
共 47 条
[21]   Use of kinetic plots for the optimization of the separation time in ultra-high-pressure LC [J].
Eeltink, Sebastiaan ;
Decrop, Wim M. C. ;
Steiner, Frank ;
Ursem, Mario ;
Cabooter, Deirdre ;
Desmet, Gert ;
Kok, Wim Th. .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (17-18) :2629-2635
[22]   Experimental investigation of the band broadening 3 originating from the top and bottom walls in micromachined nonporous pillar array columns [J].
Eghbali, Hamed ;
De Malsche, Wim ;
De Smet, Jan ;
Billen, Jeroen ;
De Pra, Mauro ;
Kok, Wim Th. ;
Schoenmakers, Peter J. ;
Gardeniers, Han ;
Desmet, Gert .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (16) :2605-2613
[23]  
Eghbali H, 2007, LC GC EUR, V20, P208
[24]   State, of the art of shear driven chromatography - Advantages and limitations [J].
Fekete, Veronika ;
Clicq, David ;
De Malsche, Wim ;
Gardeniers, Han ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1149 (01) :2-11
[25]   An electrochromatography chip with integrated waveguides for UV absorbance detection [J].
Gustafsson, O. ;
Mogensen, K. B. ;
Ohlsson, P. D. ;
Liu, Y. ;
Jacobson, S. C. ;
Kutter, J. P. .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (05)
[26]   General rules for the optimal external porosity of LC supports [J].
Gzil, P ;
Vervoort, N ;
Baron, GV ;
Desmet, G .
ANALYTICAL CHEMISTRY, 2004, 76 (22) :6707-6718
[27]   Computational study of the band broadening in two-dimensional etched packed bed columns for on-chip high-performance liquid chromatography [J].
Gzil, P ;
De Smet, J ;
Vervoort, N ;
Verelst, H ;
Baron, GV ;
Desmet, G .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1030 (1-2) :53-62
[28]   Fabrication of nanocolumns for liquid chromatography [J].
He, B ;
Tait, N ;
Regnier, F .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3790-3797
[29]   Experimental study of the depth influence on the band broadening effect in a cyclo-olefin polymer column containing an array of ordered pillars [J].
Illa, Xavi ;
De Malsche, Wim ;
Gardeniers, Han ;
Desmet, Gert ;
Romano-Rodriguez, Albert .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (37) :5817-5821
[30]   An array of ordered pillars with retentive properties for pressure-driven liquid chromatography fabricated directly from an unmodified cyclo olefin polymer [J].
Illa, Xavi ;
De Malsche, Wim ;
Bomer, Johan ;
Gardeniers, Han ;
Eijkel, Jan ;
Morante, Joan Ramon ;
Romano-Rodriguez, Albert ;
Desmet, Gert .
LAB ON A CHIP, 2009, 9 (11) :1511-1516