Custom-Fit Total Knee Arthroplasty: Our Initial Experience in 32 Knees

被引:72
作者
Bali, Kamal [1 ]
Walker, Peter [1 ]
Bruce, Warwick [1 ]
机构
[1] Univ New S Wales, Concord Repatriat Gen Hosp, Sydney, NSW, Australia
关键词
custom-fit technique; total knee arthroplasty; COMPUTER-ASSISTED SURGERY; ALIGNMENT; REPLACEMENT; NAVIGATION; MALALIGNMENT; TKA;
D O I
10.1016/j.arth.2011.12.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We share our initial experience of total knee arthroplasty (TKA) using customized cutting block technology in 32 TKAs from May 2010 to March 2011. Ten of these patients had prior TKA done on the other side using conventional or navigation-assisted TKA. Customized cutting blocks were generated for each of the knee using preoperative magnetic resonance imaging of knee and long-leg weight-bearing radiographs. At 6 weeks, long-leg radiographs were obtained to evaluate the coronal alignment. There were no adverse intraoperative events. Twenty-nine of the 32 knees had a mechanical axis restored to within 3 degrees degrees of neutral. Of 10 patients with prior TKA without custom-fit technology, the mean blood loss and the mean skin-to-skin time was found to be lower in knees that had undergone custom-fit TKA. We conclude that this technology can be safely used in most of the cases of osteoarthritis.
引用
收藏
页码:1149 / 1154
页数:6
相关论文
共 28 条
[1]   Computer assisted navigation in total knee arthroplasty - Comparison with conventional methods [J].
Anderson, KC ;
Buehler, KC ;
Markel, DC .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :132-138
[2]   The effect of component malalignment on the clinical and radiological outcome of the Kinemax total knee replacement [J].
Bankes, MJK ;
Back, DL ;
Cannon, SR ;
Briggs, TWR .
KNEE, 2003, 10 (01) :55-60
[3]   Computer navigation versus standard instrumentation for TKA - A single-surgeon experience [J].
Bolognesi, M ;
Hofmann, A .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :162-169
[4]   Computer-assisted total knee replacement - A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol) [J].
Chauhan, SK ;
Clark, GW ;
Lloyd, S ;
Scott, RG ;
Breidahl, W ;
Sikorski, JM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (06) :818-823
[5]   Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique [J].
Chin, PL ;
Yang, KY ;
Yeo, SJ ;
Lo, NN .
JOURNAL OF ARTHROPLASTY, 2005, 20 (05) :618-626
[6]   Does Accurate Anatomical Alignment Result in Better Function and Quality of Life? Comparing Conventional and Computer-Assisted Total Knee Arthroplasty [J].
Choong, Peter F. ;
Dowsey, Michelle M. ;
Stoney, James D. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (04) :560-569
[7]   Surgical Strategies to Achieve a Custom-fit TKA With Standard Implant Technique [J].
Davis, Jason J. ;
Bono, James V. .
ORTHOPEDICS, 2010, 33 (08) :569-576
[8]   Leg axis after computer-navigated total knee arthroplasty - A prospective randomized trial comparing computer-navigated and manual implantation [J].
Decking, R ;
Markmann, Y ;
Fuchs, J ;
Puhl, W ;
Scharf, HP .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :282-288
[9]   PREDICTION OF TOTAL KNEE MOTION USING A 3-DIMENSIONAL COMPUTER-GRAPHICS MODEL [J].
GARG, A ;
WALKER, PS .
JOURNAL OF BIOMECHANICS, 1990, 23 (01) :45-&
[10]   Computer-assisted total knee arthroplasty using patient-specific templating [J].
Hafez, M. A. ;
Chelule, K. L. ;
Seedhom, B. B. ;
Sherman, K. P. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (444) :184-192