The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position

被引:49
作者
Dubov, A. [1 ]
Kim, S. Y. R. [2 ]
Shah, S. [1 ,2 ]
Schemitsch, E. H. [1 ,3 ]
Zdero, R. [1 ,2 ]
Bougherara, H. [2 ]
机构
[1] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON, Canada
[3] Univ Toronto, Fac Med, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
finite element analysis; femur; hip implant; plate; periprosthetic fracture; FEMORAL-SHAFT FRACTURES; FINITE-ELEMENT-ANALYSIS; MECHANICAL-PROPERTIES; STRAIN DISTRIBUTION; SYNTHETIC FEMURS; CANCELLOUS BONE; FIXATION; ARTHROPLASTY; REPLACEMENT; STEM;
D O I
10.1177/0954411911410642
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optimal surgical positioning of cable-screw pairs in repairing periprosthetic femur fractures near the tip of a total hip implant still remains unclear. No studies in the literature to date have developed a fully three-dimensional finite element (FE) model that has been validated experimentally to assess these injury patterns. The aim of the present study was to evaluate the biomechanical performance of three different implant-bone constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. Experimentally, three bone-plate repair configurations were applied to the periprosthetic synthetic femur fractured with a 5 mm gap near the tip of a total hip implant. Constructs A, B, and C, respectively, had successively larger distances between the most proximal and the most distal cable-screw pairs used to affix the plate. Specimens were oriented in 15 degrees adduction, subjected to 1000 N of axial force to simulate the single-legged stance phase of walking, and instrumented with strain gauges. Computationally, a linearly elastic and isotropic three-dimensional FE model was developed to mimic the experimental setup. Results showed excellent agreement between experimental versus FE analysis strains, yielding a Pearson linearity coefficient, R(2), of 0.90 and a slope for the line of best data fit of 0.96. FE axial stiffnesses were 601 N/mm (Construct A), 849 N/mm (Construct B), and 1359 N/mm (Construct C). FE surface stress maps for cortical bone showed maximum von Mises values of 74 MPa (Construct A), 102 MPa (Construct B), and 57 MPa (Construct C). FE stress maps for the metallic components showed minimum von Mises values for Construct C, namely screw (716 MPa), cable (445 MPa), plate (548 MPa), and hip implant (154 MPa). In the case of good bone stock, as modelled by the present synthetic femur model, optimal fixation can be achieved with Construct C.
引用
收藏
页码:857 / 865
页数:9
相关论文
共 37 条
[1]  
Beals RK, 1996, CLIN ORTHOP RELAT R, P238
[2]  
BETHEA JS, 1982, CLIN ORTHOP RELAT R, P95
[3]   The reliability and validity of the Vancouver classification of femoral fractures after hip replacement [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
JOURNAL OF ARTHROPLASTY, 2000, 15 (01) :59-62
[4]  
Brady OH, 1999, Tech Orthop, V14, P107
[5]  
Chapman M.W., 2001, CHAPMANS ORTHOPAEDIC, P671
[6]   FRACTURES OF THE FEMUR IN RELATION TO CEMENTED HIP PROSTHESES [J].
COOKE, PH ;
NEWMAN, JH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :386-389
[7]   Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[8]   Fixation of periprosthetic femoral shaft fractures: A biomechanical comparison of two techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
Di Cesare, PE .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) :177-180
[9]   Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 2000, 15 (04) :523-528
[10]   Influence of muscle forces on femoral strain distribution [J].
Duda, GN ;
Heller, M ;
Albinger, J ;
Schulz, O ;
Schneider, E ;
Claes, L .
JOURNAL OF BIOMECHANICS, 1998, 31 (09) :841-846