Fully covered self-expandable metal stent with an anti-migration system vs plastic stent for distal biliary obstruction caused by borderline resectable pancreatic cancer A protocol for systematic review

被引:3
|
作者
Tamura, Takashi [1 ]
Yamaue, Hiroki [2 ]
Itonaga, Masahiro [1 ]
Kawaji, Yuki [1 ]
Nuta, Junya [1 ]
Hatamaru, Keiichi [1 ]
Yamashita, Yasunobu [1 ]
Kitahata, Yuji [2 ]
Miyazawa, Motoki [2 ]
Hirono, Seiko [2 ]
Okada, Ken-ichi [2 ]
Kawai, Manabu [2 ]
Shimokawa, Toshio [3 ]
Kitano, Masayuki [1 ]
机构
[1] Wakayama Med Univ, Dept Internal Med 2, 811-1 Kimiidera, Wakayama 6418509, Japan
[2] Wakayama Med Univ, Dept Surg 2, Wakayama, Japan
[3] Wakayama Med Univ, Clin Study Support Ctr, Wakayama, Japan
关键词
biliary obstruction; borderline resectable pancreatic cancer; fully covered self-expandable metal stent; plastic stent; RECEIVING NEOADJUVANT THERAPY; DRAINAGE; COMPLICATIONS; DECOMPRESSION; MULTICENTER; MANAGEMENT; EFFICACY; OUTCOMES; SAFETY;
D O I
10.1097/MD.0000000000018718
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim: Biliary obstruction can impair the effectiveness of neo-adjuvant chemotherapy. This study was designed to compare biliary stenting with covered self-expandable metal stents (FCSEMS) and plastic stents (PS) in patients with biliary obstruction caused by borderline resectable pancreatic cancer (BRPC) who were undergoing neo-adjuvant chemotherapy during preoperative biliary drainage. Methods: This single-center, comparative, randomized, superiority study was designed to compare FCSEMS with PS for drainage of biliary obstruction of BRPC. Twenty two eligible patients providing informed consent will be randomized 1:1 by computer to either FCSEMS or PS for endoscopic retrograde biliary drainage (ERBD). All subsequent clinical interventions, including crossover to alternative procedures, will be at the discretion of the treating physician based on standard clinical care. The primary outcomes will be the rates and causes of stent dysfunction during preoperative biliary drainage. Other outcomes include time required for ERBD, adverse events related to ERBD, period from ERBD to surgery, percentage of patients able to undergo surgery, operation time, intraoperative bleeding volume, postoperative adverse events, and postoperative hospitalization. Subjects, treating clinicians, and outcome assessors will not be blinded to assignment. Discussion: This study is intended to determine whether FCSEMS or PS is the better biliary stent for ERBD for management of patients with biliary obstruction of BRPC, a common clinical dilemma that has not yet been investigated in randomized trials.
引用
收藏
页数:6
相关论文
共 33 条
  • [21] Intraductal fully covered self-expandable metal stent versus multiple plastic stents for treating biliary anastomotic strictures after liver transplantation
    Sissingh, Noor J.
    de Vries, Boudewijn A.
    Inderson, Akin
    van Hoek, Bart
    van der Heide, Frans
    van Hooft, Jeanin E.
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (04) : 704 - 714
  • [22] Efficacy of a novel self-expandable metal stent with dumbbell-shaped flare ends for distal biliary obstruction due to unresectable pancreatic cancer
    Miyazawa, Masaki
    Takatori, Hajime
    Okafuji, Hirofumi
    Hayashi, Tomoyuki
    Toyama, Tadashi
    Yamada, Shinya
    Kitamura, Kazuya
    Arai, Kuniaki
    Sakai, Yoshio
    Yamashita, Taro
    Yamashita, Tatsuya
    Mizukoshi, Eishiro
    Honda, Masao
    Kaneko, Shuichi
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [23] A Short Fully Covered Self-Expandable Metal Stent for Management of Benign Biliary Stricture Not Caused by Living-Donor Liver Transplantation
    Lee, See-Young
    Jang, Sung-Ill
    Chung, Moon-Jae
    Cho, Jae-Hee
    Do, Min-Young
    Lee, Hye-Sun
    Yang, Juyeon
    Lee, Dong-Ki
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [24] Covered self-expandable metallic stent versus plastic stent for preoperative endoscopic biliary drainage in patients with pancreatic cancer: a multi-center retrospective cohort study
    Ichikawa, Hironao
    Iwashita, Takuji
    Iwasa, Yuhei
    Uemura, Shinya
    Tezuka, Ryuichi
    Okuno, Mitsuru
    Mukai, Tsuyoshi
    Yoshida, Kensaku
    Maruta, Akinori
    Iwata, Keisuke
    Murase, Katsutoshi
    Osada, Shinji
    Kawai, Masahiko
    Yasuda, Ichiro
    Shimizu, Masahito
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2022, 57 (04) : 493 - 500
  • [25] Comparison of outcomes between secondary fully covered and uncovered self-expandable metal stents in the treatment of recurrent biliary obstruction of pancreatic cancer
    Kataoka, Kunio
    Kawashima, Hiroki
    Ohno, Eizaburo
    Ishikawa, Takuya
    Mizutani, Yasuyuki
    Iida, Tadashi
    Furukawa, Kazuhiro
    Nakamura, Masanao
    Honda, Takashi
    Ishigami, Masatoshi
    Fujishiro, Mitsuhiro
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (08): : 5676 - 5683
  • [26] Covered self-expandable metal stents versus plastic stents for preoperative biliary drainage in patient receiving neo-adjuvant chemotherapy for borderline resectable pancreatic cancer: Prospective randomized study
    Tamura, Takashi
    Itonaga, Masahiro
    Ashida, Reiko
    Yamashita, Yasunobu
    Hatamaru, Keiichi
    Kawaji, Yuki
    Emori, Tomoya
    Kitahata, Yuji
    Miyazawa, Motoki
    Hirono, Seiko
    Okada, Ken-ichi
    Kawai, Manabu
    Shimokawa, Toshio
    Yamaue, Hiroki
    Kitano, Masayuki
    DIGESTIVE ENDOSCOPY, 2021, 33 (07) : 1170 - 1178
  • [27] Covered vs. uncovered self-expandable metal stents for malignant distal biliary strictures: a systematic review and meta-analysis
    Tringali, Alberto
    Hassan, Cesare
    Rota, Matteo
    Rossi, Marta
    Mutignani, Massimiliano
    Aabakken, Lars
    ENDOSCOPY, 2018, 50 (06) : 631 - 641
  • [28] Trial protocol: a randomised controlled trial to verify the non-inferiority of a partially covered self-expandable metal stent to an uncovered self-expandable metal stent for biliary drainage during neoadjuvant therapy in patients with pancreatic cancer with obstructive jaundice (PUN-NAC trial)
    Kuwatani, Masaki
    Kawakubo, Kazumichi
    Sugimori, Kazuya
    Inoue, Hiroyuki
    Kamada, Hideki
    Ishiwatari, Hirotoshi
    Kato, Shin
    Iwashita, Takuji
    Yoshida, Makoto
    Hashimoto, Shinichi
    Itonaga, Masahiro
    Mizukami, Yusuke
    Nomura, Yusuke
    Katanuma, Akio
    Sakamoto, Naoya
    BMJ OPEN, 2021, 11 (07):
  • [29] Plastic or self-expandable metal stent: Which is the most suitable for patients with pancreatic head cancer in the upcoming era of neoadjuvant chemotherapy? A review
    Hasegawa, Sho
    Endo, Itaru
    Kubota, Kensuke
    DIGESTIVE ENDOSCOPY, 2022, 34 (02) : 297 - 306
  • [30] Endoscopic Stenting of a Fully Covered Self-Expandable Metal Stent with a Hole in Each Cavity in Malignant Hilar Biliary Obstruction: A Preclinical Proof-of-Concept Study and Initial Human Experience
    Lee, Jungnam
    Jeong, Seok
    Lee, Don Haeng
    Lim, Jung-Hyun
    Kobayashi, Makoto
    Takenaka, Mamoru
    Kwon, Chang-, II
    DIGESTIVE DISEASES AND SCIENCES, 2025, 70 (03) : 1215 - 1222