Robustness of models developed by multivariate calibration. Part I: The assessment of robustness

被引:94
作者
Zeaiter, M
Roger, JM
Bellon-Maurel, V
Rutledge, DN
机构
[1] M CIRAD ITAP, Res Grp Cemagref Agro, F-34033 Montpellier, France
[2] INRA, INAPG, UMR, F-75005 Paris, France
关键词
experimental design; IR spectroscopy; multivariate calibration; on-line analysis; robustness; robustness criteria;
D O I
10.1016/S0165-9936(04)00307-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring products for quality assurance in real-time during industrial processes has become of great importance in recent years. Infrared spectroscopic (IRS) techniques combined with multivariate calibration methods are primarily used for on-line analysis, in situ sensors or automatic sampling. In order to ensure the correct use of these methods for routine industrial use, all the mechanical and the environmental conditions need to be taken into account, as well as the introduction of time delays and signal bias during sampling. This requires a robustness study of the IRS measurement and the calibration model used. In this review, we focus on both identifying the "robustness" used for multivariate calibration and the different methods applied to evaluate this robustness, especially with regard to the IRS technique used in industry. We also present and discuss various criteria intended for robustness assessment. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:157 / 170
页数:14
相关论文
共 90 条
[1]  
ABDELMALEK L, 1993, COM EUR TRAIN COURS
[2]   ORTHOGONAL MAIN-EFFECT PLANS FOR ASYMMETRICAL FACTORIAL EXPERIMENTS [J].
ADDELMAN, S .
TECHNOMETRICS, 1962, 4 (01) :21-+
[3]  
*AFNOR, 1994, NFX07001 AFNOR
[4]  
[Anonymous], 1998, 572551998 ISO
[5]  
[Anonymous], 1994, ISO 5725-1
[6]  
[Anonymous], STP PHARM PRATIQUES
[7]   Development and validation of a near infrared method for the analytical control of a pharmaceutical preparation in three steps of the manufacturing process [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
Pou, N .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (05) :534-539
[8]   IMPROVING THE QUALITY OF AN OPTIMAL POWER-FLOW SOLUTION BY TAGUCHI METHOD [J].
BOUNOU, M ;
LEFEBVRE, S ;
DO, XD .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1995, 17 (02) :113-118
[9]   SIGNAL-TO-NOISE RATIOS, PERFORMANCE CRITERIA, AND TRANSFORMATIONS [J].
BOX, G .
TECHNOMETRICS, 1988, 30 (01) :1-17
[10]  
Box G.E.P., 1960, Technometrics, V2, P455, DOI [10.1080/00401706.1960.10489912, DOI 10.1080/00401706.1960.10489912]