Simultaneous determination of albumin and immunoglobulin G with fluorescence spectroscopy and multivariate calibration

被引:40
作者
Wiberg, K
Sterner-Molin, A
Jacobsson, SP
机构
[1] AstraZeneca R&D Sodertalje, Analyt Dev, SE-15185 Sodertalje, Sweden
[2] Univ Stockholm, Dept Analyt Chem, SE-10691 Stockholm, Sweden
关键词
determination; albumin; immunoglobulin G; fluorescence spectroscopy; multivariate calibration;
D O I
10.1016/j.talanta.2003.08.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is proposed for the simultaneous determination of albumin and immunoglobulin G (IgG1) with fluorescence spectroscopy and multivariate calibration with partial least squares regression (PLS). The influence of some instrumental parameters were investigated with two experimental designs comprising 19 and 11 experiments, respectively. The investigated parameters were excitation and emission slit, detection voltage and scan rate. When a suitable instrumental setting had been found, a minor calibration and test set were analysed and evaluated. Thereafter, a larger calibration of albumin and IgG1 was made out of 26 samples (0-42 mug ml(-1) albumin and 0-12.7 mug ml(-1) IgG1). This calibration was validated with a test set consisting of 14 samples in the same concentration range. The precision of the method was estimated by analysing two test set samples for six times each. The scan modes tested were emission scan and synchronous scan Delta60 nm. The results showed that the method could be used for determination of albumin and IgG1 (albumin, root mean square error of prediction (RMSEP) <2, relative standard error of prediction (RSEP) <6% and IgG1, RMSEP <1, RSEP <8%) in spite of the overlapping fluorescence of the two compounds. The estimated precision was relative standard deviation (R.S.D.) < 1.7%. The method was finally applied for the analysis of some sample fractions from an albumin standard used in affinity chromatography. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:567 / 574
页数:8
相关论文
共 17 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]   Flow injection chemiluminometric determination of albumin [J].
Deftereos, NT ;
Grekas, N ;
Calokerinos, AC .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :137-143
[3]   Review article: albumin as a drug - biological effects of albumin unrelated to oncotic pressure [J].
Evans, TW .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2002, 16 :6-11
[4]   PARTIAL LEAST-SQUARES REGRESSION - A TUTORIAL [J].
GELADI, P ;
KOWALSKI, BR .
ANALYTICA CHIMICA ACTA, 1986, 185 :1-17
[5]  
GORE MG, 2000, SPECTROPHOMETRY SPEC, P47
[6]  
GUILBAULT GG, 1990, MODERN MONOGRAPHS AN, V3, P20
[7]  
HAGE DS, 1987, J CHROMATOGR, V386, P37
[8]   Determination of albumin and globulin at nanogram levels by a resonance light-scattering technique with alpha,beta,gamma,delta-tetrakis(4-sulfophenyl)porphine [J].
Huang, CZ ;
Zhu, JX ;
Li, KA ;
Tong, SY .
ANALYTICAL SCIENCES, 1997, 13 (02) :263-268
[9]  
LAKOWICZ JR, 1990, PRINCIPLES FLUORESCE, P342
[10]   Fluorimetric determination of albumin and globulin in human serum using tetra-substituted sulphonated aluminum phthalocyanine [J].
Li, DH ;
Yang, HH ;
Zhen, H ;
Fang, Y ;
Zhu, QZ ;
Xu, JG .
ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) :185-189