An experimental investigation on performance analysis of air type photovoltaic thermal collector system integrated with cooling fins design

被引:159
|
作者
Mojumder, Juwel Chandra [1 ]
Chong, Wen Tong [1 ]
Ong, Hwai Chyuan [1 ]
Leong, K. Y. [2 ]
Abdullah-Al-Mamoon [1 ]
机构
[1] Univ Malaya, Dept Mech Engn, Fac Engn, Kuala Lumpur 50603, Malaysia
[2] Univ Pertahanan Nas Malaysia, Dept Mech Engn, Kuala Lumpur 57000, Malaysia
关键词
Photovoltaic thermal (PV/T); Solar air collector; Thermal efficiency; Heat gain; Green energy; Cooling fin; PV/T SOLAR COLLECTORS; FLAT; SIMULATION; EFFICIENCY; GEOMETRY; HEATERS; DEVICES; MODULE; ENERGY; COST;
D O I
10.1016/j.enbuild.2016.08.040
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Photovoltaic thermal (PV/T) system was introduced to meet the thermal and electrical energy. The heat removal by air or water prevents the deterioration of the PV cell efficiency due to the overheating of cells. In this study, an air type single pass PV/T collector system was proposed where a number of thin rectangular fins were introduced for heat dissipation. The collector's performance was analyzed with a fin system that was integrated by a thin flat metallic sheet (TFMS). Then, the temperature parameters were measured and compared to several operating conditions and configurations. Analytical expression was derived from the energy balance equations for each component of the design. Average temperatures from the top/rear PV surfaces, the collector back wall surface and the collector inlet/outlet temperatures were experimentally recorded under different fin numbers (0-4), mass flow rates (0.02 kg/s-0.14 kg/s) and solar radiations (200 W/m(2)-700 W/m(2)). These readings were used in calculating the thermal and electrical efficiency of the proposed PV/T system. The maximum thermal efficiency and PV efficiency were obtained about 56.19% and 13.75% respectively for four fins at 0.14 kg/s of mass flow rate and 700 W/m2 of solar radiation. Besides, the root mean square percentages of deviation (e) and coefficient of correlation (r) were used to validate the result while also discussing the uncertainty values. This research will be helpful to design thermal collectors and provide valuable information regarding performance improvement methods in PV/T systems. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:272 / 285
页数:14
相关论文
共 50 条
  • [31] Experimental investigation of thermal performance of a heating system combining solar air collector with hollow ventilated interior wall
    Yu, Tao
    Zhao, Jiangdong
    Zhou, Jiri
    Lei, Bo
    RENEWABLE ENERGY, 2020, 147 : 1825 - 1835
  • [32] An empirical analysis on photovoltaic thermal system with fin design by forced air circulation
    Mojumder, Juwel Chandra
    Ong, Hwai Chyuan
    Chong, Wen Tong
    Leong, Kin Yuen
    Izadyar, Nima
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (05) : 2549 - 2557
  • [33] Performance analysis of a photovoltaic thermal-thermoelectric cooler air collector integrated with a mixed-mode greenhouse solar dryer
    Singh, Ajay Pratap
    Tiwari, Sumit
    Sinhmar, Harender
    INTERNATIONAL JOURNAL OF EXERGY, 2024, 45 (1-2) : 1 - 23
  • [34] Performance analysis of thermosyphon hybrid photovoltaic thermal collector
    Mutombo, N. Marc-Alain
    Inambao, Freddie
    Bright, Glen
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2016, 27 (01) : 28 - 38
  • [35] Experimental investigation on photovoltaic panel integrated with fins and cotton wicks
    Wahile, Ganesh S.
    Londhe, Shrikant D.
    Shaikh, Javed Sikandar
    Bhakre, Someshwar
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2025, 47 (01) : 11286 - 11304
  • [36] A comparative experimental study on the performance of photovoltaic thermal air collectors
    Chen, Yaowen
    Duan, Qiong
    Liu, Yanfeng
    Wang, Dengjia
    Zhuang, Zhaoben
    Qu, Lei
    Dang, Daifeng
    Shi, Lijun
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [37] Performance analysis of a concentrated system with series photovoltaic/thermal module and solar thermal collector integrated with PCM and TEG
    Wen, Xin
    Ji, Jie
    Li, Zhaomeng
    Song, Zhiying
    ENERGY, 2022, 249
  • [38] NUMERICAL AND EXPERIMENTAL INVESTIGATION FOR HYBRID PHOTOVOLTAIC/THERMAL COLLECTOR SYSTEM IN DUHOK CITY
    Khaled, Semyan
    Ali, Omar
    JOURNAL OF ENVIRONMENTAL ENGINEERING AND LANDSCAPE MANAGEMENT, 2020, 28 (04) : 202 - 212
  • [39] Design and performance optimization of a novel zigzag channeled solar photovoltaic thermal system: Numerical investigation and parametric analysis
    Attia, Mohammed El Hadi
    Zayed, Mohamed E.
    Kabeel, A. E.
    Khelifa, Abdelkrim
    Arici, Muslum
    Abdelgaied, Mohamed
    JOURNAL OF CLEANER PRODUCTION, 2024, 434
  • [40] Experimental analysis for the photovoltaic thermal collector (PVT) with nano PCM and micro-fins tube nanofluid
    Bassam, Abdulsahib M.
    Sopian, Kamaruzzaman
    Ibrahim, Adnan
    Fauzan, Mohd Faizal
    Al-Aasam, Anwer B.
    Abusaibaa, Ghaith Yahay
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 41