Estimation of the octanol-water distribution coefficient of basic compounds by a cationic microemulsion electrokinetic chromatography system

被引:4
作者
Fernandez-Pumarega, Alejandro [1 ,2 ]
Martin-Sanz, Belen [1 ,2 ]
Amezqueta, Susana [1 ,2 ]
Fuguet, Elisabet [1 ,2 ,3 ]
Roses, Marti [1 ,2 ]
机构
[1] Univ Barcelona, Fac Quim, Dept Engn Quim & Quim Analit, Marti i Franques 1-11, E-08028 Barcelona, Spain
[2] Univ Barcelona, Fac Quim, Inst Biomed IBUB, Marti i Franques 1-11, E-08028 Barcelona, Spain
[3] Generalitat Catalunya, Serra Hunter Programme, Barcelona, Spain
关键词
Lipophilicity; log P-o/w; log D-o/w; MEEKC; ionized bases; solvation parameter model; microemulsion; system surrogation; SOLUTE-SOLVENT INTERACTIONS; PARTITION-COEFFICIENTS; HYDROPHOBICITY; LIPOPHILICITY; PARAMETERS; BEHAVIOR;
D O I
10.5599/admet.760
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The octanol-water partition coefficient (P-o/w), or the octanol-water distribution coefficient (D-o/w) for ionized compounds, is a key parameter in the drug development process. In a previous work, this parameter was estimated through the retention factor measurements in a sodium dodecyl sulfate (SDS) - microemulsion electrokinetic chromatography (MEEKC) system for acidic compounds. Nonetheless, when ionized basic compounds were analyzed, undesirable ion pairs were formed with the anionic surfactant and avoided a good estimation of log D-o/w. For this reason, an alternative MEEKC system based on a cationic surfactant has been evaluated to estimate P-o/w or D-o/w of neutral compounds and ionized bases. To this end, it has been characterized through the solvation parameter model (SPM) and compared to the octanol-water partition system. Results pointed out that both systems show a similar partition behavior. Hence, the log P-o/w of a set of neutral compounds has been successfully correlated against the logarithm of the retention factor (log k) determined in this MEEKC system. Then, the log D-o/w of 6 model bases have been estimated at different pH values and they have been compared to data from the literature, determined by the reference shake-flask and potentiometric methods. Good agreement has been observed between the literature and the estimated values when the base is neutral or partially ionized (up to 99 % of ionization).
引用
收藏
页码:98 / 112
页数:15
相关论文
共 38 条
[2]   Linear free energy relationship analysis of microemulsion electrokinetic chromatographic determination of lipophilicity [J].
Abraham, MH ;
Treiner, C ;
Roses, M ;
Rafols, C ;
Ishihama, Y .
JOURNAL OF CHROMATOGRAPHY A, 1996, 752 (1-2) :243-249
[3]   HYDROGEN-BONDING .32. AN ANALYSIS OF WATER-OCTANOL AND WATER-ALKANE PARTITIONING AND THE DELTA-LOG-P PARAMETER OF SEILER [J].
ABRAHAM, MH ;
CHADHA, HS ;
WHITING, GS ;
MITCHELL, RC .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (08) :1085-1100
[4]   Setup and validation of shake-flask procedures for the determination of partition coefficients (logD) from low drug amounts [J].
Andres, Axel ;
Roses, Marti ;
Rafols, Clara ;
Bosch, Elisabeth ;
Espinosa, Sonia ;
Segarra, Victor ;
Huerta, Josep M. .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2015, 76 :181-191
[5]  
[Anonymous], BIOL
[6]  
Avdeef A., 2012, ABSORPTION DRUG DEV, P108, DOI [10.1002/9781118286067, DOI 10.1002/9781118286067]
[7]  
Baker D.R., 1995, CAPILLARY ELECTROPHO, P39
[8]   WATER SOLUBILITY AND OCTANOL-WATER PARTITION-COEFFICIENTS OF ORGANICS - LIMITATIONS OF THE SOLUBILITY-PARTITION COEFFICIENT CORRELATION [J].
BANERJEE, S ;
YALKOWSKY, SH ;
VALVANI, SC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1980, 14 (10) :1227-1229
[9]  
BARBATO F, 1990, FARMACO, V45, P647
[10]   DETERMINATION OF OCTANOL WATER PARTITION-COEFFICIENTS FOR HYDROPHOBIC ORGANIC-CHEMICALS WITH THE SLOW-STIRRING METHOD [J].
DEBRUIJN, J ;
BUSSER, F ;
SEINEN, W ;
HERMENS, J .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1989, 8 (06) :499-512