An improved constrained simultaneous iterative reconstruction technique for ionospheric tomography

被引:21
|
作者
Yao, Yibin [1 ]
Zhai, Changzhi [1 ]
Kong, Jian [2 ]
Zhao, Cunjie [1 ]
Luo, Yiyong [1 ]
Liu, Lei [1 ]
机构
[1] Wuhan Univ, Sch Geodesy & Geomat, Wuhan 430079, Peoples R China
[2] Wuhan Univ, Chinese Antarctic Ctr Surveying & Mapping, Wuhan 430079, Peoples R China
基金
美国国家科学基金会;
关键词
Three-dimensional computerized ionospheric tomography; Electron density; GNSS; Simultaneous iteration reconstruction technique; TOTAL ELECTRON-CONTENT; ALGORITHM; NEQUICK;
D O I
10.1007/s10291-020-00981-4
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Global Navigation Satellite System (GNSS) is now widely used for continuous ionospheric observations. Three-dimensional computerized ionospheric tomography (3DCIT) is an important tool for the reconstruction of electron density distributions in the ionosphere through effective use of the GNSS data. More specifically, the 3DCIT technique is able to resolve the three-dimensional electron density distributions over the reconstructed area based on the GNSS slant total electron content (STEC) observations. We present an Improved Constrained Simultaneous Iterative Reconstruction Technique (ICSIRT) algorithm that differs from the traditional ionospheric tomography methods in 3 ways. First, the ICSIRT computes the electron density corrections based on the product of the intercept and electron density within voxels so that the assignment of corrections at different heights becomes more reasonable. Second, an Inverse Distance Weighted (IDW) interpolation is used to restrict the electron density values in the voxels not traversed by GNSS rays, thereby ensuring the smoothness of the reconstructed region. Also, to improve the reconstruction accuracy around the HmF2 (the peak height of the F2 layer) altitude, a multiresolution grid is adopted in the vertical direction, with a 10-km resolution from 200 to 420 km and a 50-km resolution at other altitudes. The new algorithm has been applied to the GNSS data over the European and North American regions in different case studies that involve different seasonal conditions as well as a major storm. In the European region experiment, reconstruction results show that the new ICSIRT algorithm can effectively improve the reconstruction of the GNSS data. The electron density profiles retrieved from ICSIRT are much closer to the ionosonde observations than those from its predecessor, namely, the Constrained Simultaneous Iteration Reconstruction Technique (CSIRT). The reconstruction accuracy is significantly improved. In the North American region experiment, the electron density profiles in ICSIRT results show better agreement with incoherent scatter radar observations than CSIRT, even for the topside profiles.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] An improved constrained simultaneous iterative reconstruction technique for ionospheric tomography
    Yibin Yao
    Changzhi Zhai
    Jian Kong
    Cunjie Zhao
    Yiyong Luo
    Lei Liu
    GPS Solutions, 2020, 24
  • [2] GPS-based ionospheric tomography with a constrained adaptive simultaneous algebraic reconstruction technique
    Wen Debao
    Zhang Xiao
    Tong Yangjin
    Zhang Guangsheng
    Zhang Min
    Leng Rusong
    JOURNAL OF EARTH SYSTEM SCIENCE, 2015, 124 (02) : 283 - 289
  • [3] GPS-based ionospheric tomography with a constrained adaptive simultaneous algebraic reconstruction technique
    Wen D.B.
    Zhang X.
    Tong Y.
    Zhang G.
    Zhang M.
    Leng R.
    Journal of Earth System Science, 2015, 124 (2) : 283 - 289
  • [4] An adaptive simultaneous iteration reconstruction technique for three-dimensional ionospheric tomography
    Yao Yi-Bin
    Tang Jun
    Zhang Liang
    He Chang-Yong
    Zhang Shun
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2014, 57 (02): : 345 - 353
  • [5] Constrained simultaneous algebraic reconstruction technique (C-SART) —a new and simple algorithm applied to ionospheric tomography
    Thomas Hobiger
    Tetsuro Kondo
    Yasuhiro Koyama
    Earth, Planets and Space, 2008, 60 : 727 - 735
  • [6] Dimensionality reduced simultaneous iterative reconstruction technique for electrical resistance tomography
    Ren, Shangjie
    Zhao, Jia
    Dong, Feng
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 46 : 284 - 291
  • [7] Tomographic reconstruction of ionospheric electron density based on constrained algebraic reconstruction technique
    Wen, Debao
    Liu, Sanzhi
    Tang, Pingying
    GPS SOLUTIONS, 2010, 14 (04) : 375 - 380
  • [8] An improved reconstruction algorithm for computerized ionospheric tomography
    Wu, XB
    Xu, JS
    Ma, SY
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2000, 43 (01): : 19 - +
  • [9] A new ionospheric tomographic algorithm — constrained multiplicative algebraic reconstruction technique (CMART)
    Debao Wen
    Sanzhi Liu
    Journal of Earth System Science, 2010, 119 : 489 - 496
  • [10] A new ionospheric tomographic algorithm - constrained multiplicative algebraic reconstruction technique (CMART)
    Wen Debao
    Liu Sanzhi
    JOURNAL OF EARTH SYSTEM SCIENCE, 2010, 119 (04): : 489 - 496