Predicting scleral GP lens entrapped tear layer oxygen tensions

被引:40
作者
Jaynes, Jared M. [1 ]
Edrington, Timothy B. [1 ]
Weissman, Barry A. [1 ]
机构
[1] Marshall B Ketchum Univ, Southern Calif Coll Optometry, Fullerton, CA 92831 USA
关键词
Scleral lenses; Oxygen tension; Corneal hypoxia; Tear reservoir; Oxygen transmissibility; CORNEAL; CONSUMPTION; TRANSMISSIBILITY; THICKNESS;
D O I
10.1016/j.clae.2014.09.008
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/Purpose: Over the past decade, utilization of scleral gas permeable (GP) contact lenses has steadily increased. Scleral GP lenses offer yet another option for patients suffering from visually debilitating corneal and tear conditions. Oxygen delivery to the cornea in the presence of a contact lens system continues to be a subject of interest, and scleral GP lenses are no exception. This paper utilizes an existing model based on simultaneous two lens systems (piggyback lenses) as a resistance to oxygen in series, and applies this model to scleral GP lens systems. Methods: Theoretical oxygen tensions are calculated for tear layers trapped beneath scleral contact lens systems and the anterior corneal surface with a simple single chamber corneal model using a computer software spreadsheet. Results: Only the best case scenario for current scleral gas permeable lenses (thickness and Dk)/tear layer values allow sufficient tear layer oxygen tension (approximately 100 mmHg) to preclude corneal hypoxia. Conclusions: The results of the spreadsheet model suggest that clinicians would be prudent to prescribe scleral GP lenses manufactured in the highest Dk materials available and to fit without excessive corneal clearance to minimize anterior segment hypoxia. (C) 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:44 / 47
页数:4
相关论文
共 26 条
[1]  
Benjamin W. J., 2006, INVESTIG OPHTHALMOL, V47
[2]  
Bonanno JA, 2002, INVEST OPHTH VIS SCI, V43, P371
[3]   Beyond flux: Total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear [J].
Brennan, NA .
OPTOMETRY AND VISION SCIENCE, 2005, 82 (06) :467-472
[4]  
BRENNAN NA, 2005, CLIN CONTACT LENS PR, P41
[5]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[6]   STEADY-STATE DISTRIBUTION OF OXYGEN AND CARBON DIOXIDE IN IN VIVO CORNEA .I. OPEN EYE IN AIR AND CLOSED EYE [J].
FATT, I ;
BIEBER, MT .
EXPERIMENTAL EYE RESEARCH, 1968, 7 (01) :103-&
[7]  
FATT I, 1977, AM J OPTOM PHYS OPT, V54, P666
[8]  
FATT I, 1971, AMER J OPT ARCH AM A, V48, P545
[9]  
Fatt I, 1989, NEUE OTICKERJOURNAL, P31
[10]  
Fatt I, 1993, J BR CONTACT LENS AS, V16, P141