Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs

被引:17
作者
Chang, Jinhwa [1 ,2 ]
Kim, Sujin [3 ,4 ]
Jung, Joohyun [1 ,2 ]
Lee, Heechun [5 ]
Choi, Hojung [7 ]
Chang, Dongwoo [6 ]
Lee, Youngwon [6 ]
Yoon, Junghee [1 ,2 ]
Choi, Mincheol [1 ,2 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Med Imaging, Seoul 151742, South Korea
[2] Seoul Natl Univ, Res Inst Vet Sci, Seoul 151742, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul 110460, South Korea
[4] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul 110460, South Korea
[5] Gyeongsang Natl Univ, Coll Vet Med, Dept Med Imaging, Jinju 600701, South Korea
[6] Chungbuk Natl Univ, Coll Veterinaty Med, Dept Med Imaging, Chonju 361763, South Korea
[7] Chungnam Natl Univ, Coll Vet Med, Dept Diagnost Imaging, Taejon 305764, South Korea
关键词
computed tomography; dog; glomerular filtration rate; UNIT RENAL VOLUME; HELICAL CT; NEPHROGRAPHIC-PHASE; KIDNEY; CORTICOMEDULLARY; CLEARANCE; IOHEXOL; BOLUS; MASS;
D O I
10.4142/jvs.2011.12.4.393
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The objective of our study was to determine individual and global glomerular filtration rates (GFRs) using dynamic renal computed tomography (CT) in Beagle dogs. Twenty-four healthy Beagle dogs were included in the experiment. Anesthesia was induced in all dogs by using propofol and isoflurane prior to CT examination. A single slice of the kidney was sequentially scanned after a bolus intravenous injection of contrast material (iohexol, 1 mL/kg, 300 mgI/mL). Time attenuation curves were created and contrast clearance per unit volume was calculated using a Patlak plot analysis. The CT-GFR was then determined based on the conversion of contrast clearance per unit volume to contrast clearance per body weight. At the renal hilum, CT-GFR values per unit renal volume (mL/min/mL) of the right and left kidneys were 0.69 +/- 0.04 and 0.57 +/- 0.05, respectively. No significant differences were found between the weight-adjusted CT-GFRs in either kidney at the same renal hilum (p = 0.747). The average global G FR was 4.21 +/- 0.25 mL/min/kg and the whole kidney GFR was 33.43 +/- 9.20 mL/min. CT-GFR techniques could be a practical way to separately measure GFR in each kidney for clinical and research purposes.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 33 条
[1]   Single-slice dynamic computed tomographic determination of glomerular filtration rate by use of Patlak plot analysis in anesthetized pigs [J].
Alexander, Kate ;
del Castillo, Jerome R. E. ;
Ybarra, Norma ;
Morin, Valerie ;
Gauvin, Domianique ;
Authier, Simon ;
Vinay, Patrick ;
Troncy, Eric .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2007, 68 (03) :297-304
[2]   The quantification of renal function with enhanced computed tomography [J].
Blomley, MJK ;
Dawson, P .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (827) :989-995
[3]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[4]   Evaluation of the effects of thiopental, propofol, and etomidate on glomerular filtration rate measured by the use of dynamic computed tomography in dogs [J].
Chang, Jinhwa ;
Kim, Sujin ;
Jung, Joohyun ;
Lee, Heechun ;
Chang, Dongwoo ;
Lee, Youngwon ;
Lee, Inhyung ;
Yoon, Junghee ;
Choi, Mincheol .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2011, 72 (01) :146-151
[5]   RENAL MASSES - ASSESSMENT OF CORTICOMEDULLARY-PHASE AND NEPHROGRAPHIC-PHASE CT SCANS [J].
COHAN, RH ;
SHERMAN, LS ;
KOROBKIN, M ;
BASS, JC ;
FRANCIS, IR .
RADIOLOGY, 1995, 196 (02) :445-451
[6]   Helical CT examination of potential kidney donors [J].
Dachman, AH ;
Newmark, GM ;
Mitchell, MT ;
Woodle, ES .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) :193-200
[7]   DYNAMIC CONTRAST BOLUS COMPUTED-TOMOGRAPHY FOR THE ASSESSMENT OF RENAL-FUNCTION [J].
DAWSON, P ;
PETERS, M .
INVESTIGATIVE RADIOLOGY, 1993, 28 (11) :1039-1042
[8]   Dynamic contrast-enhanced functional imaging with multi-slice CT [J].
Dawson, P .
ACADEMIC RADIOLOGY, 2002, 9 :S368-S370
[9]   Functional imaging in CT [J].
Dawson, Peter .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) :331-340
[10]   Contrast media as markers of GFR [J].
Frennby, B ;
Sterner, G .
EUROPEAN RADIOLOGY, 2002, 12 (02) :475-484