Assessment of right ventricular function for patients with rheumatic mitral stenosis by 64-slice multi-detector row computed tomography: comparison with magnetic resonance imaging

被引:4
作者
Zhang Xiao-chun [2 ]
Yang Zhi-gang [1 ]
Guo Yin-kun [1 ]
Zhang Rui-ming [3 ]
Wang Jian [2 ]
Zhou Dai-quan [2 ]
Cheng Lin [2 ]
Chen Lin [2 ]
机构
[1] Sichuan Univ, W China Hosp, Dept Radiol, Chengdu 610041, Sichuan, Peoples R China
[2] Third Mil Med Univ, Southwest Hosp, Dept Radiol, Chongqing 400038, Peoples R China
[3] First Affiliated Hosp, Inner Mongolia Med Coll, Dept Gen Surg, Hohhot 410041, Inner Mongolia, Peoples R China
关键词
cardiac imaging techniques; ventricular function; mitral valve stenosis; magnetic resonance imaging; VALVULAR HEART-DISEASE; EJECTION FRACTION; CARDIAC-FUNCTION; CT; ECHOCARDIOGRAPHY; ACCURACY; REPRODUCIBILITY; FAILURE; VOLUMES;
D O I
10.3760/cma.j.issn.0366-6999.2012.08.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Right ventricular (RV) dysfunction ensues due to rheumatic mitral stenosis (RMS). The evaluation of RV function is clinically important for the diagnosis, treatment, and follow-up for patients with different degrees of RMS. The purpose of this study was to determine whether the 64-slice multi-detector row computed tomography (64-slice MDCT) can assess the RV function in RMS with high accuracy and reproducibility when compared to MR imaging (MRI). Methods Right ventricular end-diastolic and end-systolic volumes (RV-EDV and RV-ESV), stroke volume (RV-SV), ejection fraction (RV-EF), cardiac output (RV-CO), and wall mass (RV-Mass) were measured with dedicated cardiac analysis software on 64-slice MDCT and compared with values measured with MRI in 43 consecutive patients with RMS. Agreement between MRI and 64-MDCT results were compared with Bland and Altman analysis and linear regression analysis. Repeated measurements were performed to determine intraobserver and interobserver variability. Results No significant differences were revealed in calculated RV function parameters between the two methods. RV-EDV, RV-ESV, RV-SV, RV-EF, RV-CO, and RV-Mass by 64-slice MDCT were similar to those by MRI (P>0.05). There were good correlations (r=0.98, 0.97, 0.96, 0.96, 0.95 and 0.77, respectively) and close agreement (bias=-0.2 ml, -1.0 ml, 0.8 ml, 0.5%, 26.1 ml, and 0.5 g, respectively, P>0.05). The variability in 64-slice MDCT measurements was similar to that in MRI values. Conclusion ECG-gated 64-slice MDCT could assess the RV function in RMS with high accuracy and reproducibility when compared to MRI. Chin Med J 2012;125(8):1469-1474
引用
收藏
页码:1469 / 1474
页数:6
相关论文
共 50 条
[41]   In-stent area stenosis on 64-slice multi-detector computed tomography coronary angiography: optimal cutoff value for minimum lumen cross-sectional area of coronary stents compared with intravascular ultrasound [J].
Kwon, Woocheol ;
Choi, Jiyoun ;
Kim, Jang-Young ;
Kim, Seong-Yoon ;
Yoon, Junghan ;
Choe, Kyoung-Hoon ;
Lee, Seung Hwan ;
Ahn, Sung Gyun .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 :21-31
[42]   Comparison of 64-slice computed tomography angiography and coronary angiography for the detection and assessment of coronary artery disease in patients with angina: A systematic review [J].
Powell, H. ;
Cosson, P. .
RADIOGRAPHY, 2013, 19 (02) :168-175
[43]   Dynamic Assessment of Right Ventricular Volumes and Function by Real-Time Three-Dimensional Echocardiography: A Comparison Study With Magnetic Resonance Imaging in 100 Adult Patients [J].
Leibundgut, Gregor ;
Rohner, Andreas ;
Grize, Leticia ;
Bernheim, Alain ;
Kessel-Schaefer, Arnheid ;
Bremerich, Jens ;
Zellweger, Michael ;
Buser, Peter ;
Handke, Michael .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (02) :116-126
[44]   Accuracy and variability of right ventricular volumes and mass assessed by dual-source computed tomography: influence of slice orientation in comparison to magnetic resonance imaging [J].
Christoph J. Jensen ;
Alexander Wolf ;
Holger C. Eberle ;
Michael Forsting ;
Kai Nassenstein ;
Thomas C. Lauenstein ;
Georg V. Sabin ;
Oliver Bruder ;
Thomas Schlosser .
European Radiology, 2011, 21 :2492-2502
[45]   Feasibility of Cardiac Computed Tomography for the Evaluation of Ventricular Function in Postoperative Children With Congenital Heart Disease: Comparison With Cardiac Magnetic Resonance Imaging [J].
Xie, Wei-Hui ;
Guo, Chen ;
Hu, Li-Wei ;
Ouyang, Rong-Zhen ;
Yao, Xiao-Fen ;
Sun, Ai-Min ;
Qiu, Hai-Sheng ;
Yan, Qin ;
Zhu, Ya-Xin ;
Wang, Qian ;
Zhong, Yu-Min .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (04) :537-543
[46]   Magnetic Resonance Imaging and Computed Tomography in Emergency Assessment of Patients with Suspected Acute Stroke: A Prospective Comparison [J].
Ahmed, Adnan ;
Nazir, Memona ;
Jami, Ajmaal ;
Tahir, Muhammad ;
Khalil, Mahnoor ;
Baig, Tahir .
PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (06) :1898-1902
[47]   Value of Speckle Tracking for the Assessment of Right Ventricular Function in Patients Operated on for Tetralogy of Fallot. Comparison with Magnetic Resonance Imaging [J].
Bernard, Yvette ;
Morel, Mathilde ;
Descotes-Genon, Vincent ;
Jehl, Jerome ;
Meneveau, Nicolas ;
Schiele, Francois .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (04) :474-482
[48]   Pulmonary vein morphology by free-breathing whole heart magnetic resonance imaging at 3 tesla versus breathhold multi-detector computed tomography [J].
Fodi, Eszter ;
McAreavey, Dorothea ;
Abd-Elmoniem, Khaled Z. ;
Ohayon, Jacques ;
Saba, Magdi ;
Elagha, Abdalla ;
Pettigrew, Roderic I. ;
Gharib, Ahmed M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) :846-852
[49]   Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography - Comparison with cine magnetic resonance imaging [J].
Belge, Benedicte ;
Coche, Emmanuel ;
Pasquet, Agnes ;
Vanoverschelde, Jean-Louis J. ;
Gerber, Bernhard L. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1424-1433
[50]   Influence of left ventricular geometry and function on aortic annular dimensions as assessed with multi-detector row computed tomography: implications for transcatheter aortic valve implantation [J].
Ng, Arnold C. T. ;
Yiu, Kai-Hang ;
Ewe, See Hooi ;
van der Kley, Frank ;
Bertini, Matteo ;
de Weger, Arend ;
de Roos, Albert ;
Leung, Dominic Y. ;
Schuijf, Joanne D. ;
Schalij, Martin J. ;
Bax, Jeroen J. ;
Delgado, Victoria .
EUROPEAN HEART JOURNAL, 2011, 32 (22) :2806-2813