Comparison of 99mTc-DMSA, 99mTc-DTPA and 99mTc-MAG3 Renal Scintigraphy in the Calculation of Relative Renal Function

被引:3
|
作者
Demir, Fadime [1 ]
Demir, Mustafa [2 ]
机构
[1] Tokat Gaziosmanpasa Univ, Fac Med, Dept Nucl Med, Tokat, Turkey
[2] Firat Univ, Fac Med, Dept Nephrol, Elazig, Turkey
来源
JOURNAL OF UROLOGICAL SURGERY | 2020年 / 7卷 / 02期
关键词
Relative renal function; Tc-99m DMSA renal cortical scintigraphy; Dynamic renal scintigraphy; CHILDREN; OBSTRUCTION; RENOGRAPHY; MAG3;
D O I
10.4274/jus.galenos.2019.3107
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to compare Tc-(9)(9m) dimercaptosuccinic acid (Tc-99m-DMSA) renal cortical scintigraphy and Tc-(9)(9m) diethylene triamine pentaacetic acid (Tc-99m-DTPA) and Tc-(9)(9m) mercaptoacetyltriglycine (Tc-99m-MAG3) dynamic renal scintigraphy in the evaluation of relative renal function (RRF). Materials and Methods: Forty seven patients with renal cortical scintigraphy (with Tc-99m-DMSA) and dynamic renal scintigraphy (with Tc-99m-DTPA or Tc-99m-MAG3) were included in this retrospective study. RRF obtained from Tc-99m-DMSA, Tc-99m-DTPA and Tc-99m-MAG3 scintigraphies, clinical and demographic data were statistically analyzed. Results: There was a high correlation between Tc-99m-DMSA renal cortical scintigraphy and dynamic renal scintigraphy (Tc-99m-DTPA or Tc-99m-MAG3) in terms of RRF evaluation (r=0.981, p<0.001 and r=0.918, p=<0.001, respectively). While the Bland Altman plot showed an average difference of 3.30 between RRFs measured by Tc-99m-DMSA and by Tc-99m-DTPA, the difference between that with Tc-99m-DMSA and Tc-99m-MAG3 was 0.08. Conclusion: In conclusion, this study showed a high level of compliance between Tc-99m-DMSA renal scintigraphy and dynamic renal scintigraphy (Tc-99m or Tc-99m-MAG3) in the evaluation of RRF. Time loss, radiation exposed to the patients and economic losses are minimized with the use of a single method suitable for the purpose.
引用
收藏
页码:130 / 133
页数:4
相关论文
共 50 条
  • [1] Renal Uptakes of 99mTc-MAG3, 99mTc-DTPA, and 99mTc-DMSA in Rabbits with Unilateral Ureteral Obstruction
    Lee, Won Guk
    Kim, Joong-Hyun
    Kim, Jong Min
    Shim, Kyung Mi
    Kang, Seong Soo
    Chae, Hong In
    Choi, Seok Hwa
    IN VIVO, 2010, 24 (02): : 137 - 139
  • [2] Comparison of relative renal functions calculated with 99mTc-DTPA and 99mTc-DMSA for kidney patients of wide age ranges
    Momin, M. A.
    Abdullah, M. N. A.
    Reza, M. S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 99 - 105
  • [3] 99mTc-DTPA diuretic renal scintigraphy in dogs with nephroureterolithiasis
    Hecht, Silke
    Lawson, S. Meg
    Lane, India F.
    Sharp, Dorothy E.
    Daniel, Gregory B.
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2010, 51 (12): : 1360 - 1366
  • [4] Comparison of irregular manual adjusted and regular elliptic regions of interests for the calculation of relative renal function in Renal Scintigraphy with 99mTc-DMSA
    Duarte, A.
    Santos, P.
    Chin, S.
    Santos, A.
    Filipe, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S487 - S488
  • [5] Comparing the Relative Glomerular Filtration Rate with the Relative Renal Function Calculated by 99mTc-DMSA Static Scintigraphy
    Hu, Wei
    Pu, Xiaojia
    Shao, Kejing
    Wang, Fei
    Zhu, Bao
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (07) : 1603 - 1608
  • [6] 99mTc-MAG3 Renography of Intrathoracic Renal Ectopia
    ten Broek, Marc R. J.
    te Beek, Erik T.
    Stuurman-Wieringa, Roos E.
    CLINICAL NUCLEAR MEDICINE, 2019, 44 (01) : 78 - 80
  • [7] Pharmacokinetics of 99mTc-MAG3
    Vivier, Pierre-Hugues
    Dacher, Jean-Nicolas
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (04) : W361 - W361
  • [8] Evaluation of Renal Function in Obstructed Ureter Model Using 99mTc-DMSA
    Jang, Seok Jin
    Choi, Byung Soo
    Choi, Seok Hwa
    IN VIVO, 2020, 34 (05): : 2431 - 2435
  • [9] The reproducibility of measurements of differential renal function in paediatric 99mTc-MAG3 renography
    Brink, Anita
    Samal, Martin
    Mann, Michael D.
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (08) : 824 - 831
  • [10] Assessment of renal function in mice with unilateral ureteral obstruction using 99mTc-MAG3 dynamic scintigraphy
    Tantawy, Mohammed N.
    Jiang, Rosie
    Wang, Feng
    Takahashi, Keiko
    Peterson, Todd E.
    Zemel, Dana
    Hao, Chuan-Ming
    Fujita, Hiroki
    Harris, Raymond C.
    Quarles, Christopher C.
    Takahashi, Takamune
    BMC NEPHROLOGY, 2012, 13