Assessment of Anterior Segment Tumors with Ultrasound Biomicroscopy versus Anterior Segment Optical Coherence Tomography in 200 Cases

被引:94
|
作者
Bianciotto, Carlos [1 ]
Shields, Carol L. [1 ]
Guzman, Juan M. [1 ]
Romanelli-Gobbi, Massi [1 ]
Mazzuca, Douglas, Jr. [1 ]
Green, W. Ross [1 ]
Shields, Jerry A. [1 ]
机构
[1] Thomas Jefferson Univ, Wills Eye Inst, Ocular Oncol Serv, Philadelphia, PA 19107 USA
关键词
IRIS; MANAGEMENT; OCT;
D O I
10.1016/j.ophtha.2010.11.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare ultrasound biomicroscopy (UBM) versus anterior segment optical coherence tomography (AS-OCT) for imaging of tumors of the anterior segment of the eye. Design: Retrospective, noninterventional case series. Participants: We included 200 patients. Methods: Review of medical records of patients who underwent both UBM and AS-OCT for evaluation of anterior segment tumors. Main Outcome Measures: Comparison of tumor surface and internal visualization. Results: There were 200 eyes with anterior segment tumors involving the iris stroma in 96 (48%), ciliary body in 14 (7%), combined iris and ciliary body in 32 (16%), iris pigment epithelium (IPE) in 44 (22%), conjunctiva in 6 (3%), sclera in 4 (2%), and others in 6 (1% each). The diagnoses included nevus in 75 eyes (38%), melanoma in 47 (24%), cyst in 48 (24%), epithelioma (adenoma) in 5 (3%), metastasis, melanocytosis and melanocytoma in 4 eyes each (2%), and others (1% each). Image analysis (UBM vs AS-OCT) revealed adequate visualization of all tumor margins (189 [95%] vs 80 [40%]), posterior tumor shadowing (9 [5%] vs 144 [72%]), and high overall image quality (159 [80%] vs 136 [68%]). Comparison for better image resolution (UBM vs AS-OCT) disclosed UBM provided better overall tumor visualization (138 [69%] vs 62 [31%]) and better resolution of the posterior margin (147 [74%] vs 53 [27%]), whereas AS-OCT provided better resolution of the anterior margin (40 [20%] vs 160 [80%]) as well as better overall resolution of anterior segment anatomy (41 [21%] vs 159 [80%]). Better resolution was found with UBM for pigmented tumors (n = 162; 107 [66%] vs 55 [34%]) as well as for nonpigmented tumors (n = 38; 23 [61%] vs 15 [39%]). Regarding location, iris tumor resolution was similar with each technique (49 [52%] vs 45 [48%]). Conclusions: For anterior segment tumors, UBM offers better visualization of the posterior margin and provides overall better images for entire tumor configuration compared with AS-OCT.
引用
收藏
页码:1297 / 1302
页数:6
相关论文
共 50 条
  • [11] Scleral Lens Clearance Assessment with Biomicroscopy and Anterior Segment Optical Coherence Tomography
    Yeung, Debby
    Sorbara, Luigina
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (01) : 13 - 20
  • [12] Comparison of anterior segment optical coherence tomography (OCT) and ultrasound biomicroscopy (UBM) in diagnosis of anterior scleritis
    Purgert, Robert
    Bessette, Angela
    Pichi, Francesco
    Lowder, Careen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [13] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Yu, Zi-Yan
    Huang, Ting
    Lu, Lu
    Qu, Bo
    WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (15) : 3249 - U143
  • [14] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Zi-Yan Yu
    Ting Huang
    Lu Lu
    Bo Qu
    World Journal of Clinical Cases, 2020, (15) : 3249 - 3258
  • [15] Comparison of ultrasound biomicroscopy and spectraldomain anterior segment optical coherence tomography in evaluation of anterior segment after laser peripheral iridotomy
    Xiao-Yun Ma
    Dan Zhu
    Jun Zou
    Wen-Jie Zhang
    Yi-Lin Cao
    International Journal of Ophthalmology, 2016, 9 (03) : 417 - 423
  • [16] Imaging implanted keratoprostheses with anterior-segment optical coherence tomography and ultrasound biomicroscopy
    Garcia, Julian P. S., Jr.
    de la Cruz, Jose
    Rosen, Richard B.
    Buxton, Douglas E.
    CORNEA, 2008, 27 (02) : 180 - 188
  • [17] Correlation of anterior segment optical coherence tomography and ultrasound biomicroscopy in congenital corneal opacity
    Yangzes, Sonam
    Kaushik, Sushmita
    Malhotra, Chintan
    Thakur, Anchal
    Gupta, Amit
    Jain, Arun Kumar
    Jinagal, Jitender
    Pandav, Surinder Singh
    JOURNAL OF AAPOS, 2024, 28 (02):
  • [18] Imaging the Canaliculops With Ultrasound Biomicroscopy and Anterior Segment Ocular Coherence Tomography
    Singh, Swati
    Ali, Mohammad Javed
    Peguda, Hari Kumar
    Naik, Milind N.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2017, 33 (06): : E143 - E144
  • [19] Ultrasound biomicroscopy in anterior segment tumors evaluation
    Chojniak, MMM
    Allemann, N
    Erwenne, CM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2784 - 2784
  • [20] Anterior Segment Optical Coherence Tomography as a Screening Tool for the Assessment of the Anterior Segment Angle
    Pekmezci, Melike
    Porco, Travis C.
    Lin, Shan C.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (04) : 389 - 398