Assessment of Anterior Segment Tumors with Ultrasound Biomicroscopy versus Anterior Segment Optical Coherence Tomography in 200 Cases

被引:94
作者
Bianciotto, Carlos [1 ]
Shields, Carol L. [1 ]
Guzman, Juan M. [1 ]
Romanelli-Gobbi, Massi [1 ]
Mazzuca, Douglas, Jr. [1 ]
Green, W. Ross [1 ]
Shields, Jerry A. [1 ]
机构
[1] Thomas Jefferson Univ, Wills Eye Inst, Ocular Oncol Serv, Philadelphia, PA 19107 USA
关键词
IRIS; MANAGEMENT; OCT;
D O I
10.1016/j.ophtha.2010.11.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare ultrasound biomicroscopy (UBM) versus anterior segment optical coherence tomography (AS-OCT) for imaging of tumors of the anterior segment of the eye. Design: Retrospective, noninterventional case series. Participants: We included 200 patients. Methods: Review of medical records of patients who underwent both UBM and AS-OCT for evaluation of anterior segment tumors. Main Outcome Measures: Comparison of tumor surface and internal visualization. Results: There were 200 eyes with anterior segment tumors involving the iris stroma in 96 (48%), ciliary body in 14 (7%), combined iris and ciliary body in 32 (16%), iris pigment epithelium (IPE) in 44 (22%), conjunctiva in 6 (3%), sclera in 4 (2%), and others in 6 (1% each). The diagnoses included nevus in 75 eyes (38%), melanoma in 47 (24%), cyst in 48 (24%), epithelioma (adenoma) in 5 (3%), metastasis, melanocytosis and melanocytoma in 4 eyes each (2%), and others (1% each). Image analysis (UBM vs AS-OCT) revealed adequate visualization of all tumor margins (189 [95%] vs 80 [40%]), posterior tumor shadowing (9 [5%] vs 144 [72%]), and high overall image quality (159 [80%] vs 136 [68%]). Comparison for better image resolution (UBM vs AS-OCT) disclosed UBM provided better overall tumor visualization (138 [69%] vs 62 [31%]) and better resolution of the posterior margin (147 [74%] vs 53 [27%]), whereas AS-OCT provided better resolution of the anterior margin (40 [20%] vs 160 [80%]) as well as better overall resolution of anterior segment anatomy (41 [21%] vs 159 [80%]). Better resolution was found with UBM for pigmented tumors (n = 162; 107 [66%] vs 55 [34%]) as well as for nonpigmented tumors (n = 38; 23 [61%] vs 15 [39%]). Regarding location, iris tumor resolution was similar with each technique (49 [52%] vs 45 [48%]). Conclusions: For anterior segment tumors, UBM offers better visualization of the posterior margin and provides overall better images for entire tumor configuration compared with AS-OCT.
引用
收藏
页码:1297 / 1302
页数:6
相关论文
共 24 条
  • [1] Ultrasound biomicroscopy and optical coherence tomography imaging of filtering blebs after deep sclerectomy with new collagen implant
    Aptel, Florent
    Dumas, Sophie
    Denis, Philippe
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (02) : 223 - 230
  • [2] Imaging of Iris lesions with high-speed optical coherence tomography
    Bakri, Sophie J.
    Singh, Arun D.
    Lowder, Careen Y.
    Chalita, Maria Regina
    Li, Yan
    Izatt, Joseph A.
    Rollins, Andrew M.
    Huang, David
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (01) : 27 - 34
  • [3] Ultrasound biomicroscopy: role in diagnosis and management in 130 consecutive patients evaluated for anterior segment tumours
    Conway, RM
    Chew, T
    Golchet, P
    Desai, K
    Lin, S
    O'Brien, J
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (08) : 950 - 955
  • [4] Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment
    Dada, Tanuj
    Sihota, Ramanjit
    Gadia, Ritu
    Aggarwal, Anand
    Mandal, Subrata
    Gupta, Viney
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) : 837 - 840
  • [5] Ultrasound biomicroscopy and OCT findings in posterior microphthalmos
    Erdoel, H.
    Kola, M.
    Tuerk, A.
    Akyol, N.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2008, 18 (03) : 479 - 482
  • [6] Imaging implanted keratoprostheses with anterior-segment optical coherence tomography and ultrasound biomicroscopy
    Garcia, Julian P. S., Jr.
    de la Cruz, Jose
    Rosen, Richard B.
    Buxton, Douglas E.
    [J]. CORNEA, 2008, 27 (02) : 180 - 188
  • [7] Anterior segment imaging for glaucoma: OCT or UBM?
    Ishikawa, Hiroshi
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1420 - 1421
  • [8] MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY
    IZATT, JA
    HEE, MR
    SWANSON, EA
    LIN, CP
    HUANG, D
    SCHUMAN, JS
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) : 1584 - 1589
  • [9] Comparison of Internal Anterior Chamber Diameter Imaging Modalities: 35-MHz Ultrasound Biomicroscopy, Visante Optical Coherence Tomography, and Pentacam
    Kim, Sang-Kyoon
    Kim, Hyo-Myung
    Song, Jong-Suk
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (02) : 120 - 126
  • [10] Ultrasound biomicroscopic imaging of the anterior aspect of peripheral choroidal melanomas
    Maberly, DAL
    Pavlin, CJ
    McGowan, HD
    Foster, FS
    Simpson, ER
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 123 (04) : 506 - 514