Analyzing occupational heat stress using sensor-based monitoring: a wearable approach with environmental ergonomics perspective

被引:0
作者
Sharma, M. [1 ]
Suri, N. M. [1 ]
Kant, S. [1 ]
机构
[1] Punjab Engn Coll Deemed Univ, Dept Prod & Ind Engn, Sect 12, Chandigarh 160012, India
关键词
Heat exposure; Occupational safety; Risk assessment; Sensors; Work environment; THERMAL COMFORT; WORKERS; TEMPERATURE; HUMIDITY; EXPOSURE; HEALTH; PLANT; RISK; WBGT;
D O I
10.1007/s13762-021-03862-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Occupational heat stress could impose a greater risk of heat-related morbidities among the exposed users, declining their work productivity and contributing to a financial burden. This necessitate the implementation of adequate preventive measures and control policies to improve the users' well-being and productive capacity. The emergence of modernistic sensors gives rise to workplace heat stress monitoring at a substantially lower cost than expensive conventional equipment. Present work unveils the productive role of sensor-based safety helmet, which could monitor the environmental variables, heat stress indices, and users' physiological variables as an indicator of heat strain. The proposed safety helmet was tested under three different work environments with users' engaged in specific work activities. Notable variations were perceived among the measured data under respective work conditions and physical activity performed. Higher heat risk exposures were attributable to the outdoor condition compared to indoor work conditions. For wet bulb globe temperature index, strong association (p-value < 0.01) was observed with fighter index of thermal stress (R-2-value = 0.959) followed by discomfort index (R-2-value = 0.899) and heat index (R-2-value = 0.867). Results revealed a rise in measured physiological parameters under the heavy workload activity (shoveling task; outdoor location) followed by hacksaw cutting task (indoor location), while least values were associated with light workload activity (drilling task; indoor location). The proposed design intervention could be considered an effective site-specific solution for monitoring heat stress exposures and keeping exposed users well aware of the prevalent thermal work conditions at the individual level.
引用
收藏
页码:11421 / 11434
页数:14
相关论文
共 41 条
  • [1] Thermal Environment Assessment Reliability Using Temperature -Humidity Indices
    Alfano, Francesca Romana d'Ambrosio
    Palella, Boris Igor
    Riccio, Giuseppe
    [J]. INDUSTRIAL HEALTH, 2011, 49 (01) : 95 - 106
  • [2] [Anonymous], 2004, 9886 ISO, P1
  • [3] [Anonymous], 2017, 7243 ISO
  • [4] [Anonymous], 2009, 99202009 BS EN ISO
  • [5] [Anonymous], 2004, 89962004 BS EN ISO
  • [6] Investigation of thermal comfort conditions in a travertine processing plant by using thermal comfort indices
    Aritan, A. E.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2019, 16 (09) : 5285 - 5288
  • [7] A comparative study of predicting individual thermal sensation and satisfaction using wrist-worn temperature sensor, thermal camera and ambient temperature sensor
    Aryal, Ashrant
    Becerik-Gerber, Burcin
    [J]. BUILDING AND ENVIRONMENT, 2019, 160
  • [8] Australian Bureau of Meteorology, 2010, THERM COMF OBS
  • [9] Comparison of UTCI to selected thermal indices
    Blazejczyk, Krzysztof
    Epstein, Yoram
    Jendritzky, Gerd
    Staiger, Henning
    Tinz, Birger
    [J]. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2012, 56 (03) : 515 - 535
  • [10] Design and Development of a Wearable Device for Heat Stroke Detection
    Chen, Sheng-Tao
    Lin, Shih-Sung
    Lan, Chien-Wu
    Hsu, Hao-Yen
    [J]. SENSORS, 2018, 18 (01):