Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU

被引:22
|
作者
Kim, Kyung Sang [1 ]
Ye, Jong Chul [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Bioimaging & Signal Proc Lab, Taejon 305701, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 15期
关键词
IMAGE-RECONSTRUCTION; SIMULATION ALGORITHM;
D O I
10.1088/0031-9155/56/15/021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate scatter correction is especially important for high-resolution 3D positron emission tomographies (PETs) such as high-resolution research tomograph (HRRT) due to large scatter fraction in the data. To address this problem, a fully 3D iterative scatter-corrected ordered subset expectation maximization (OSEM) in which a 3D single scatter simulation (SSS) is alternatively performed with a 3D OSEM reconstruction was recently proposed. However, due to the computational complexity of both SSS and OSEM algorithms for a high-resolution 3D PET, it has not been widely used in practice. The main objective of this paper is, therefore, to accelerate the fully 3D iterative scatter-corrected OSEM using a graphics processing unit (GPU) and verify its performance for an HRRT. We show that to exploit the massive thread structures of the GPU, several algorithmic modifications are necessary. For SSS implementation, a sinogram-driven approach is found to be more appropriate compared to a detector-driven approach, as fast linear interpolation can be performed in the sinogram domain through the use of texture memory. Furthermore, a pixel-driven backprojector and a ray-driven projector can be significantly accelerated by assigning threads to voxels and sinograms, respectively. Using Nvidia's GPU and compute unified device architecture (CUDA), the execution time of a SSS is less than 6 s, a single iteration of OSEM with 16 subsets takes 16 s, and a single iteration of the fully 3D scatter-corrected OSEM composed of a SSS and six iterations of OSEM takes under 105 s for the HRRT geometry, which corresponds to acceleration factors of 125x and 141x for OSEM and SSS, respectively. The fully 3D iterative scatter-corrected OSEM algorithm is validated in simulations using Geant4 application for tomographic emission and in actual experiments using an HRRT.
引用
收藏
页码:4991 / 5009
页数:19
相关论文
共 50 条
  • [41] Effect of spatial behavior of scatter on 3D PET
    Jan, ML
    Pei, CC
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 376 - 387
  • [42] Comparative evaluation of scatter correction in 3D PET using different scatter-level approximations
    Irene Polycarpou
    Kris Thielemans
    Ravindra Manjeshwar
    Pablo Aguiar
    Paul K. Marsden
    Charalampos Tsoumpas
    Annals of Nuclear Medicine, 2011, 25 : 643 - 649
  • [43] Comparative evaluation of scatter correction in 3D PET using different scatter-level approximations
    Polycarpou, Irene
    Thielemans, Kris
    Manjeshwar, Ravindra
    Aguiar, Pablo
    Marsden, Paul K.
    Tsoumpas, Charalampos
    ANNALS OF NUCLEAR MEDICINE, 2011, 25 (09) : 643 - 649
  • [44] CHARACTERIZATION AND CORRECTION FOR SCATTER IN 3D PET USING REBINNED PLANE INTEGRALS
    WU, CW
    ORDONEZ, CE
    CHEN, CT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (06) : 2758 - 2764
  • [45] Performance Evaluation of Scatter Modeling of the GPU-based "Tera-Tomo" 3D PET Reconstruction
    Magdics, Milan
    Szirmay-Kalos, Laszlo
    Toth, Balazs
    Legrady, David
    Cserkaszky, Aron
    Balkay, Laszlo
    Domonkos, Balazs
    Voelgyes, David
    Patay, Gergely
    Major, Peter
    Lantos, Judit
    Buekki, Tamas
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4086 - 4088
  • [46] PET 3D Iterative Reconstruction on Cell BE
    Chevalier, David E.
    Drapkin, Evgeny
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4054 - 4058
  • [47] 3D-OSEM iterative image reconstruction for high-resolution PET using precalculated system matrix
    Ortuno, Juan E.
    Guerra-Gutiérrez, Pedro
    Rubio, Jose L.
    Kontaxakis, George
    Santos, Andres
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 440 - 444
  • [48] Comparison of two 3D implementations of TOF Scatter Estimation in 3D PET
    Iatrou, Maria
    Manjeshwar, Ravindra M.
    Sterns, Charles W.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3474 - +
  • [49] A FULLY 3D SMALL PET SCANNER
    TAVERNIER, S
    BRUYNDONCKX, P
    SHUPING, Z
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03): : 635 - 643
  • [50] PET Image Reconstruction Using LOR-OSEM with a 3D Spatially Variant System Matrix
    Wiant, David B.
    Gersh, Jacob A.
    Bennett, Marcus C.
    Bourland, J. Daniel
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3752 - 3758