Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU

被引:22
|
作者
Kim, Kyung Sang [1 ]
Ye, Jong Chul [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Bioimaging & Signal Proc Lab, Taejon 305701, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 15期
关键词
IMAGE-RECONSTRUCTION; SIMULATION ALGORITHM;
D O I
10.1088/0031-9155/56/15/021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate scatter correction is especially important for high-resolution 3D positron emission tomographies (PETs) such as high-resolution research tomograph (HRRT) due to large scatter fraction in the data. To address this problem, a fully 3D iterative scatter-corrected ordered subset expectation maximization (OSEM) in which a 3D single scatter simulation (SSS) is alternatively performed with a 3D OSEM reconstruction was recently proposed. However, due to the computational complexity of both SSS and OSEM algorithms for a high-resolution 3D PET, it has not been widely used in practice. The main objective of this paper is, therefore, to accelerate the fully 3D iterative scatter-corrected OSEM using a graphics processing unit (GPU) and verify its performance for an HRRT. We show that to exploit the massive thread structures of the GPU, several algorithmic modifications are necessary. For SSS implementation, a sinogram-driven approach is found to be more appropriate compared to a detector-driven approach, as fast linear interpolation can be performed in the sinogram domain through the use of texture memory. Furthermore, a pixel-driven backprojector and a ray-driven projector can be significantly accelerated by assigning threads to voxels and sinograms, respectively. Using Nvidia's GPU and compute unified device architecture (CUDA), the execution time of a SSS is less than 6 s, a single iteration of OSEM with 16 subsets takes 16 s, and a single iteration of the fully 3D scatter-corrected OSEM composed of a SSS and six iterations of OSEM takes under 105 s for the HRRT geometry, which corresponds to acceleration factors of 125x and 141x for OSEM and SSS, respectively. The fully 3D iterative scatter-corrected OSEM algorithm is validated in simulations using Geant4 application for tomographic emission and in actual experiments using an HRRT.
引用
收藏
页码:4991 / 5009
页数:19
相关论文
共 50 条
  • [31] A single scatter simulation technique for scatter correction in 3D pet
    Watson, CC
    Newport, D
    Casey, ME
    THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 255 - 268
  • [32] Analytical volume calculation of voxel fragments for iterative, fully 3D PET reconstruction
    Scheins, JJ
    Herzog, H
    Boschen, F
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2502 - 2506
  • [33] Fully 3D iterative scatter compensation in non-uniform attenuating media for SPECT.
    Beekman, FJ
    denHarder, JM
    Viergever, MA
    vanRijk, PP
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 979 - 979
  • [34] Fully 3D PET Iterative Reconstruction Using Distance-Driven Projectors and Native Scanner Geometry
    Manjeshwar, Ravindra M.
    Ross, Steven G.
    Iatrou, Maria
    Deller, Timothy W.
    Stearns, Charles W.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2804 - 2807
  • [35] Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering
    Jacobson, M
    Levkovitz, R
    Ben-Tal, A
    Thielemans, K
    Spinks, T
    Belluzzo, D
    Pagani, E
    Bettinardi, V
    Gilardi, MC
    Zverovich, A
    Mitra, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : 2417 - 2439
  • [36] Fast and efficient fully 3D PET image reconstruction using sparse system matrix factorization with GPU acceleration
    Zhou, Jian
    Qi, Jinyi
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : 6739 - 6757
  • [37] Fully 3D iterative CT reconstruction using polar coordinates
    Thibaudeau, Christian
    Leroux, Jean-Daniel
    Fontaine, Rejean
    Lecomte, Roger
    MEDICAL PHYSICS, 2013, 40 (11)
  • [38] Scatter modelling and correction strategies in fully 3-D PET
    Zaidi, H
    NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (11) : 1181 - 1184
  • [39] A comparative investigation of scatter correction in 3D PET
    Polycarpou, I.
    Marsden, P. K.
    Tsoumpas, C.
    INTERNATIONAL CONFERENCE ON IMAGE OPTIMISATION IN NUCLEAR MEDICINE (OPTINM), 2011, 317
  • [40] Advances in scatter correction for 3D PET/CT
    Watson, CC
    Casey, ME
    Michel, C
    Bendriem, B
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3008 - 3012