Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU

被引:22
|
作者
Kim, Kyung Sang [1 ]
Ye, Jong Chul [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Bioimaging & Signal Proc Lab, Taejon 305701, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 15期
关键词
IMAGE-RECONSTRUCTION; SIMULATION ALGORITHM;
D O I
10.1088/0031-9155/56/15/021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate scatter correction is especially important for high-resolution 3D positron emission tomographies (PETs) such as high-resolution research tomograph (HRRT) due to large scatter fraction in the data. To address this problem, a fully 3D iterative scatter-corrected ordered subset expectation maximization (OSEM) in which a 3D single scatter simulation (SSS) is alternatively performed with a 3D OSEM reconstruction was recently proposed. However, due to the computational complexity of both SSS and OSEM algorithms for a high-resolution 3D PET, it has not been widely used in practice. The main objective of this paper is, therefore, to accelerate the fully 3D iterative scatter-corrected OSEM using a graphics processing unit (GPU) and verify its performance for an HRRT. We show that to exploit the massive thread structures of the GPU, several algorithmic modifications are necessary. For SSS implementation, a sinogram-driven approach is found to be more appropriate compared to a detector-driven approach, as fast linear interpolation can be performed in the sinogram domain through the use of texture memory. Furthermore, a pixel-driven backprojector and a ray-driven projector can be significantly accelerated by assigning threads to voxels and sinograms, respectively. Using Nvidia's GPU and compute unified device architecture (CUDA), the execution time of a SSS is less than 6 s, a single iteration of OSEM with 16 subsets takes 16 s, and a single iteration of the fully 3D scatter-corrected OSEM composed of a SSS and six iterations of OSEM takes under 105 s for the HRRT geometry, which corresponds to acceleration factors of 125x and 141x for OSEM and SSS, respectively. The fully 3D iterative scatter-corrected OSEM algorithm is validated in simulations using Geant4 application for tomographic emission and in actual experiments using an HRRT.
引用
收藏
页码:4991 / 5009
页数:19
相关论文
共 50 条
  • [1] Fast Implementation of Fully Iterative Scatter Corrected OSEM for HRRT Using GPU
    Kim, Kyung Sang
    Ye, Jong Chul
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3330 - 3332
  • [2] GPU Acceleration of a Fully 3D Iterative Reconstruction Software for PET using CUDA
    Herraiz, J. L.
    Espana, S.
    Garcia, S.
    Cabido, R.
    Montemayor, A. S.
    Desco, M.
    Vaquero, J. J.
    Udias, J. M.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4064 - +
  • [3] Fully 3D GPU PET reconstruction
    Herraiz, J. L.
    Espana, S.
    Cal-Gonzalez, J.
    Vaquero, J. J.
    Desco, M.
    Udias, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S169 - S171
  • [4] Advancement in PET quantification using 3D-OP-OSEM PSF reconstruction with the HRRT
    Varrone, Andrea
    Sjoholm, N.
    Gulyas, B.
    Halldin, C.
    Farde, L.
    NEUROIMAGE, 2008, 41 : T85 - T85
  • [5] Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction
    Olesen, Oline Vinter
    Sibomana, Merence
    Keller, Sune Hogild
    Andersen, Flemming
    Jensen, Jorgen
    Holm, Soren
    Svarer, Claus
    Hojgaard, Liselotte
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3789 - 3790
  • [6] Benefits of 3D Scatter Correction for the HRRT - a Large Axial FOV PET Scanner
    Sibomana, Merence
    Keller, Sune H.
    Stute, Simon
    Comtat, Claude
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2954 - 2957
  • [7] A method of overlap correction for fully 3D OSEM reconstruction of PET data
    Ross, S
    Stearns, C
    Manjeshwar, R
    Iatrou, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3497 - 3500
  • [8] DETECTOR EFFICIENCY AND COMPTON SCATTER IN FULLY 3D PET
    OLLINGER, JM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1168 - 1173
  • [9] Optimization of a fully 3D single scatter simulation algorithm for 3D PET
    Accorsi, R
    Adam, LE
    Werner, ME
    Karp, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2577 - 2598
  • [10] Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT
    Andrea Varrone
    Nils Sjöholm
    Lars Eriksson
    Balazs Gulyás
    Christer Halldin
    Lars Farde
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 1639 - 1650