Characterization and corrosion evaluation of TiO2:n-HA coatings on titanium alloy formed by plasma electrolytic oxidation

被引:84
作者
Dzhurinskiy, D. [1 ]
Gao, Y. [2 ]
Yeung, W-K [2 ]
Strumban, E. [1 ]
Leshchinsky, V. [1 ]
Chu, P-J [1 ]
Matthews, A. [2 ]
Yerokhin, A. [2 ,3 ]
Maev, R. Gr. [1 ]
机构
[1] Univ Windsor, Dept Phys, Windsor, ON N9B 3P4, Canada
[2] Univ Sheffield, Dept Mat Sci & Engn, Sheffield S1 3JD, S Yorkshire, England
[3] Natl Univ Sci & Technol MISIS, Moscow 119049, Russia
基金
英国工程与自然科学研究理事会;
关键词
Coatings; Nano hydroxyapatite; Plasma electrolytic oxidation; Implant; Titanium alloy; ELECTROCHEMICAL-BEHAVIOR; HYDROXYAPATITE; GRAPHITE; FILMS;
D O I
10.1016/j.surfcoat.2015.01.022
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present study, a novel TiO2-based coating containing nanosized hydroxyapatite (n-HA) has been formed on commercially available Ti-6Al-4V (Grade 5) alloy substrates by the Plasma Electrolytic Oxidation (PEO) technique. The TiO2:n-HA coating deposition was provided in an aqueous solution of disodium hydrogen phosphate containing suspended hydroxyapatite nanoparticles under a pulsed bipolar current mode. The surface morphology of the formed coatings has been examined by Scanning Electron Microscopy (SEM), while the element composition of the coatings has been determined by Energy Dispersive X-ray analysis (EDS). The presence of HA nanoparticles within the formed coatings has been analyzed by Fourier Transform Infrared Spectroscopy (FTIR). The corrosion resistance of the TiO2:n-HA coatings has been studied by electrochemical methods, including open circuit potential, potentiodynamic polarization and electrochemical impedance spectroscopy, and compared to the corrosion behavior of bare titanium. The results indicate that the formed PEO coatings exhibit a porous network structure with embedded n-HA particles uniformly distributed over the entire surface of the coatings. The PEO coated samples showed substantially higher corrosion resistance compared to the bare Ti-6Al-4V substrate material. The PEO-formed TiO2:n-HA layers reduce the corrosion of titanium alloy implant materials and can be used as a bioactive biomimetic coating to enhance implant surface bioactivity and osseointegration. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 265
页数:8
相关论文
共 44 条
[1]  
Bhola R., 2009, Res. Lett. Phys. Chem, V2009, P0, DOI [10.1155/2009/574359, DOI 10.1155/2009/574359]
[2]   Corrosion behaviour of porous titanium-graphite composites designed for surgical implants [J].
Blackwood, DJ ;
Chua, AWC ;
Seah, KHW ;
Thampuran, R ;
Teoh, SH .
CORROSION SCIENCE, 2000, 42 (03) :481-503
[3]  
Charles J, 1987, MATER TECHNOL, V8, P309
[4]   Preparation and properties of hydroxyapatite-containing titania coating by micro-arc oxidation [J].
Chen, Jian-Zhi ;
Shi, Yu-long ;
Wang, Lei ;
Yan, Feng-ying ;
Zhang, Fu-qiang .
MATERIALS LETTERS, 2006, 60 (20) :2538-2543
[5]  
Chiesa R, 2003, J Appl Biomater Biomech, V1, P91
[6]  
Deamley P.A., 2004, WEAR, V256, P469, DOI DOI 10.1016/50043-1648(03)00557-X
[7]  
Dicu M.M., 2012, SCI B, V74, P193
[8]  
Fadl-allah S.A., 2013, J BIOMATERIALS NANOB, V4, P74, DOI DOI 10.4236/JBNB.2013.41010
[9]   Corrosion of graphite in industrial phosphoric acid [J].
Guenbour, A. ;
Iken, H. ;
Kebkab, N. ;
Bellaouchou, A. ;
Boulif, R. ;
Ben Bachir, A. .
APPLIED SURFACE SCIENCE, 2006, 252 (24) :8710-8715
[10]  
Jh N., 2008, MAT RES B, V43, P45