Quasi-Simultaneous Acquisition of Hard Electron Ionization and Soft Single-Photon Ionization Mass Spectra during GC/MS Analysis by Rapid Switching between Both Ionization Methods: Analytical Concept, Setup, and Application on Diesel Fuel

被引:36
作者
Eschner, Markus S. [1 ,2 ]
Groeger, Thomas M. [1 ,2 ]
Horvath, Thomas [3 ]
Gonin, Marc [3 ]
Zimmermann, Ralf [1 ,2 ,4 ]
机构
[1] Helmholtz Zentrum Munchen, Joint Mass Spectrometry Ctr, Cooperat Grp Anal Complex Mol Syst, Inst Ecol Chem, D-85764 Neuherberg, Germany
[2] Univ Rostock, Joint Mass Spectrometry Ctr, Chair Analyt Chem, Inst Chem, D-18059 Rostock, Germany
[3] Tofwerk AG, CH-3600 Thun, Switzerland
[4] BIfA Bavarian Inst Appl Environm Res & Technol Gm, D-86167 Augsburg, Germany
关键词
ENHANCED MULTIPHOTON IONIZATION; ONLINE GAS-ANALYSIS; GC X GC; FIELD-IONIZATION; ORGANIC-COMPOUNDS; IMPACT IONIZATION; SPECTROMETRY; CHROMATOGRAPHY; PHOTOIONIZATION; DESORPTION;
D O I
10.1021/ac200356t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes the realization of rapid switching between hard electron ionization (El) and soft single-photon ionization (SPI) integrated in a compact orthogonal acceleration time-of-flight mass spectrometer. Vacuum-ultraviolet (VUV) photons of 9.8 eV (126 nm) emitted from the innovative electron-beam-pumped rare-gas excimer light source (EBEL) filled with argon are focused into the ion chamber by an ellipsoidal mirror optic for accomplishing of SPI. This novel orthogonal acceleration time-of-flight mass spectrometer with switching capability was hyphenated to one-dimensional gas chromatography (GC) and comprehensive two-dimensional (2D) gas chromatography (GC x GC) for the first time. Within this demonstration study, a maximum switching frequency of 80 Hz was applied for investigation of a mineral-oil-type diesel sample. This approach allows the quasi-simultaneous acquisition of complementary information about the fragmentation pattern (Et) as well as the molecular mass (SPI) of compounds within a single analysis. Furthermore, by application of a polar GC column for separation, the SPI data can be displayed in a 2D contour plot, leading to a comprehensive 2D characterization (GC x MS), whereas the typical group-type assignment for diesel is also met.
引用
收藏
页码:3865 / 3872
页数:8
相关论文
共 46 条
[11]  
Gross J.H., 2004, MASS SPECTROMETRY
[12]  
Guilhaus M, 2000, MASS SPECTROM REV, V19, P65, DOI 10.1002/(SICI)1098-2787(2000)19:2<65::AID-MAS1>3.0.CO
[13]  
2-E
[14]   Determination of the Composition of Fatty Acid Mixtures Using GC x FI-MS: A Comprehensive Two-Dimensional Separation Approach [J].
Hejazi, Leila ;
Ebrahimi, Diako ;
Guilhaus, Michael ;
Hibbert, D. Brynn .
ANALYTICAL CHEMISTRY, 2009, 81 (04) :1450-1458
[15]   Compatibility of electron ionization and soft ionization methods in gas chromatography/orthogonal time-of-flight mass spectrometry [J].
Hejazi, Leila ;
Ebrahimi, Diako ;
Hibbert, D. Brynn ;
Guilhaus, Michael .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (14) :2181-2189
[16]  
Hubschmann H.-J., 2008, Handbook of GC-MS: Fundamentals and Applications, V3rd
[17]   VUV single-photon ionization ion trap time-of-flight mass spectrometer for on-line, real-time monitoring of chlorinated organic compounds in waste incineration flue gas [J].
Kuribayashi, S ;
Yamakoshi, H ;
Danno, M ;
Sakai, S ;
Tsuruga, S ;
Futami, H ;
Morii, S .
ANALYTICAL CHEMISTRY, 2005, 77 (04) :1007-1012
[18]   FIELD-IONIZATION AND FIELD DESORPTION MASS-SPECTROMETRY - PAST, PRESENT, AND FUTURE [J].
LATTIMER, RP ;
SCHULTEN, HR .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :A1201-+
[19]  
McMaster M.C., 2008, GC-MS: A practical user's guide
[20]   Comprehensive gas chromatography-time-of-flight mass spectrometry using soft and selective photoionization techniques [J].
Mitschke, Stefan ;
Welthagen, Werner ;
Zimmermann, Ralf .
ANALYTICAL CHEMISTRY, 2006, 78 (18) :6364-6375