Closed-loop identification of multivariable systems: With or without excitation of all references?

被引:21
作者
Miskovic, L. [1 ,2 ]
Karimi, A. [1 ]
Bonvin, D. [1 ]
Gevers, M. [2 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Automat, CH-1015 Lausanne, Switzerland
[2] Univ Catholique Louvain, Ctr Syst Engn & Appl Mech CESAME, B-1348 Louvain, Belgium
关键词
closed-loop identification; covariance matrices; multivariable systems; system excitation;
D O I
10.1016/j.automatica.2007.11.016
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The accuracy of plant parameters estimated in closed-loop operation is investigated for a class of multivariable systems and for the situation where only some of the reference inputs are excited. This, issue is important for at least two reasons: (i) there are control applications where it is preferable not to excite all references in order to avoid performance degradation, and (ii) it is not clear whether the results in the context of open-loop identification. where the existence of common parameters between the various transfer functions is a condition for improved accuracy with additional excitation, also hold in the closed-loop case. The paper examines the effect of the non-excitation of some reference inputs on the variance of the estimated parameters. The proposed expressions are valid for all conventional model structures used in prediction error identification. Although exciting all reference inputs is not necessary for identifiability, this work shows that, regardless of the parametrization, the excitation of all references never worsens and, in most cases, improves the accuracy of the parameter estimates. The analytical results developed in this work are illustrated by two simulation examples. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2048 / 2056
页数:9
相关论文
共 50 条
[11]   An application-oriented approach to dual control with excitation for closed-loop identification [J].
Larsson, Christian A. ;
Ebadat, Afrooz ;
Rojas, Cristian R. ;
Bombois, Xavier ;
Hjalmarsson, Hakan .
EUROPEAN JOURNAL OF CONTROL, 2016, 29 :1-16
[12]   Multivariable closed-loop identification and its application to boiler-turbine system of power unit [J].
Chen, Shi-he ;
Wang, Ya-gang ;
Zhang, Xi ;
Li, Xiao-feng .
Lecture Notes in Control and Information Sciences, 2014, 452 :249-259
[13]   Closed-loop subspace identification of multivariable dynamic errors-in-variables models based on ORT [J].
Minghong She ;
Baocang Ding .
Cluster Computing, 2019, 22 :4907-4915
[14]   Closed-loop subspace identification of multivariable dynamic errors-in-variables models based on ORT [J].
She, Minghong ;
Ding, Baocang .
CLUSTER COMPUTING-THE JOURNAL OF NETWORKS SOFTWARE TOOLS AND APPLICATIONS, 2019, 22 (02) :S4907-S4915
[15]   A projection method for closed-loop identification [J].
Forssell, U ;
Ljung, L .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2000, 45 (11) :2101-2106
[16]   Identification and control - Closed-loop issues [J].
VandenHof, PMJ ;
Schrama, RJP .
AUTOMATICA, 1995, 31 (12) :1751-1770
[17]   Closed-loop issues in system identification [J].
Van den Hof, P .
(SYSID'97): SYSTEM IDENTIFICATION, VOLS 1-3, 1998, :1547-1560
[18]   Understanding closed-loop identification with ITCLI [J].
Rivera, D. E. ;
Guzman, J. L. ;
Berenguel, M. ;
Dormido, S. .
IFAC PAPERSONLINE, 2015, 48 (28) :739-744
[19]   A parametrization for the closed-loop identification of nonlinear time-varying systems [J].
Dasgupta, S ;
Anderson, BDO .
AUTOMATICA, 1996, 32 (10) :1349-1360
[20]   Closed-loop identification of unstable systems using noncausal FIR models [J].
Aljanaideh, Khaled F. ;
Bernstein, Dennis S. .
INTERNATIONAL JOURNAL OF CONTROL, 2017, 90 (02) :184-201