Early assessment of acute ischemic stroke in rabbits based on multi-parameter near-field coupling sensing

被引:3
|
作者
Li, Gen [1 ,3 ]
Yin, Shengtong [1 ]
Jian, Man [1 ]
Chen, Jingbo [2 ]
Zeng, Lingxi [1 ]
Bai, Zelin [2 ]
Zhuang, Wei [2 ]
Xu, Bingxin [1 ]
He, Shengjie [1 ]
Sun, Jian [2 ]
Chen, Yujie [3 ]
机构
[1] Chongqing Univ Technol, Sch Pharm & Bioengn, Chongqing, Peoples R China
[2] Army Med Univ, Coll Biomed Engn, Chongqing, Peoples R China
[3] Army Med Univ, Southwest Hosp, Dept Neurosurg, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Acute ischemic stroke; Near-field coupling; Multi-parameter continuous assessment; Bilateral common carotid artery ligation; SYSTEM; TOMOGRAPHY; GUIDELINE; MODELS;
D O I
10.1186/s12938-022-00991-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Early diagnosis and continuous monitoring are the key to emergency treatment and intensive care of patients with acute ischemic stroke (AIS). Nevertheless, there has not been a fully accepted method targeting continuous assessment of AIS in clinical. Methods Near-field coupling (NFC) sensing can obtain the conductivity related to the volume of intracranial components with advantages of non-invasiveness, strong penetrability and real-time monitoring. In this work, we built a multi-parameter monitoring system that is able to measure changes of phase and amplitude in the process of electromagnetic wave (EW) reflection and transmission. For investigating its feasibility in AIS detection, 16 rabbits were chosen to establish AIS models by bilateral common carotid artery ligation and then were enrolled for monitoring experiments. Results During the 6 h after AIS, the reflection amplitude (RA) shows a decline trend with a range of 0.69 dB and reflection phase (RP) has an increased variation of 6.48 degrees . Meanwhile, transmission amplitude (TA) and transmission phase (TP) decrease 2.14 dB and 24.29 degrees , respectively. The statistical analysis illustrates that before ligation, 3 h after ligation and 6 h after ligation can be effectively distinguished by the four parameters individually. When all those parameters are regarded as recognition features in back propagation (BP) network, the classification accuracy of the three different periods reaches almost 100%. Conclusion These results prove the feasibility of multi-parameter NFC sensing to assess AIS, which is promised to become an outstanding point-of-care testing method in the future.
引用
收藏
页数:19
相关论文
共 5 条
  • [1] Early assessment of acute ischemic stroke in rabbits based on multi-parameter near-field coupling sensing
    Gen Li
    Shengtong Yin
    Man Jian
    Jingbo Chen
    Lingxi Zeng
    Zelin Bai
    Wei Zhuang
    Bingxin Xu
    Shengjie He
    Jian Sun
    Yujie Chen
    BioMedical Engineering OnLine, 21
  • [2] A non-invasive real-time monitoring system for cytotoxic brain edema in post ischemic stroke based on near-field coupling
    Li, Gen
    Zhang, Bo
    Zhang, Maoting
    Liu, Qi
    Luo, Jie
    Liao, Qi
    Tan, Mei
    Bai, Zelin
    Xu, Jia
    Sun, Jian
    Chen, Mingsheng
    TECHNOLOGY AND HEALTH CARE, 2021, 29 (05) : 963 - 978
  • [3] Non-invasive Assessment for Dynamic Cerebral Autoregulation Based on Near-Field Coupling
    Shao, Ansheng
    Li, Gen
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,
  • [4] Multi-band and broadband metamaterial perfect absorber based on conductive polymer and near-field coupling
    Le Dac Tuyen
    Pham The Linh
    Dang Hong Luu
    Le Danh Phuong
    Tong Ba Than
    Tran Manh Cuong
    Vu Dinh Lam
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2019, 33 (30):
  • [5] Prediction Method of Near-field coupling between Phase Arrays Based on Theory of Multi-ports Network
    Wu Nan
    Wang Chun
    Xie Dagang
    Chen Liang
    2013 5TH IEEE INTERNATIONAL SYMPOSIUM ON MICROWAVE, ANTENNA, PROPAGATION AND EMC TECHNOLOGIES FOR WIRELESS COMMUNICATIONS (MAPE), 2013, : 538 - 541