Aptamer Biosensors for Label-Free Colorimetric Detection of Human IgE Based on Polydiacetylene (PDA) Supramolecules

被引:10
|
作者
Kim, Jun Pyo [2 ]
Park, Cheol Hee [2 ]
Sim, Sang Jun [1 ]
机构
[1] Korea Univ, Dept Chem & Biol Engn, Seoul 136713, South Korea
[2] Sungkyunkwan Univ, Dept Chem Engn, Suwon 440746, South Korea
关键词
Polydiacetylene; Biosensor; Aptamer; IgE; IN-VITRO SELECTION; VESICLES; CHROMISM; COLOR; BIND;
D O I
10.1166/jnn.2011.3664
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, we demonstrate an aptamer-based biosensor (apta-biosensor) using PDA liposomes for label-free detection of allergy diagnosis by hIgE detection. In order to detect the target hIgE, the surface of PDA liposome were functionalized with hIgE antibody and anti-hIgE aptamer as a receptor, and the target hIgE onto the receptors was detected by the change of fluorescence signal. The hIgE antibody-modified PDA liposome biosensor had a serious problem that the immune reaction between receptor and target could not powerfully affect the change of florescence signal on PDA liposorne. In order to solve this problem, the anti-hIgE aptamer which was far smaller than whole antibody was introduced as the receptor for the PDA liposome system. An aptamer-based PDA liposome biosensor was able to measure a quantity of target protein with various concentrations and at this time the detection limit was 141 ng/mL of the hIgE concentration. These results enabled diagnosis of allergy disease by an aptamer-based PDA liposome biosensor because real allergic patients showed high concentration of hIgE in serum (greater than 290 ng/mL). Therefore, we suggest that aptamer-modified PDA supramolecules as promising candidates for development of label-free colorimetric biosensors.
引用
收藏
页码:4269 / 4274
页数:6
相关论文
共 50 条
  • [21] Label-free aptamer-based colorimetric detection of mercury ions in aqueous media using unmodified gold nanoparticles as colorimetric probe
    Li, Li
    Li, Baoxin
    Qi, Yingying
    Jin, Yan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (08) : 2051 - 2057
  • [22] A Direct, Multiplex Biosensor Platform for Pathogen Detection Based on Cross-linked Polydiacetylene (PDA) Supramolecules
    Park, Cheol Hee
    Kim, Jun Pyo
    Lee, Sang Wook
    Jeon, Noo Li
    Yoo, Pil J.
    Sim, Sang Jun
    ADVANCED FUNCTIONAL MATERIALS, 2009, 19 (23) : 3703 - 3710
  • [23] Aptamer-Based Label-Free Impedimetric Biosensor for Detection of Progesterone
    Jimenez, Gaston Contreras
    Eissa, Shimaa
    Ng, Andy
    Alhadrami, Hani
    Zourob, Mohammed
    Siaj, Mohamed
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1075 - 1082
  • [24] A Label-Free Aptasensor for Ochratoxin a Detection Based on the Structure Switch of Aptamer
    Liu, Feng
    Ding, Ailing
    Zheng, Jiushang
    Chen, Jiucun
    Wang, Bin
    SENSORS, 2018, 18 (06)
  • [25] A sensitive aptasensor based on molybdenum carbide nanotubes and label-free aptamer for detection of bisphenol A
    He, Meng-Qi
    Wang, Kun
    Wang, Jin
    Yu, Yong-Liang
    He, Rong-Huan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (07) : 1797 - 1803
  • [26] Aptamer-based biosensor for label-free detection of ethanolamine by electrochemical impedance spectroscopy
    Liang, Gang
    Man, Yan
    Jin, Xinxin
    Pan, Ligang
    Liu, Xinhui
    ANALYTICA CHIMICA ACTA, 2016, 936 : 222 - 228
  • [27] An Aptamer-Based Biosensor for Direct, Label-Free Detection of Melamine in Raw Milk
    Kaneko, Naoto
    Horii, Katsunori
    Akitomi, Joe
    Kato, Shintaro
    Shiratori, Ikuo
    Waga, Iwao
    SENSORS, 2018, 18 (10)
  • [28] Label-free detection of liver cancer cells by aptamer-based microcantilever biosensor
    Chen, Xuejuan
    Pan, Yangang
    Liu, Huiqing
    Bai, Xiaojing
    Wang, Nan
    Zhang, Bailin
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 353 - 358
  • [29] A sensitive aptasensor based on molybdenum carbide nanotubes and label-free aptamer for detection of bisphenol A
    Meng-Qi He
    Kun Wang
    Jin Wang
    Yong-Liang Yu
    Rong-Huan He
    Analytical and Bioanalytical Chemistry, 2017, 409 : 1797 - 1803
  • [30] Label-Free Biosensors Based on Aptamer-Modified Graphene Field-Effect Transistors
    Ohno, Yasuhide
    Maehashi, Kenzo
    Matsumoto, Kazuhiko
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2010, 132 (51) : 18012 - 18013