Differentiating the acute phase of gout from the intercritical phase with ultrasound and quantitative shear wave elastography

被引:17
|
作者
Wang, Qiao [1 ]
Guo, Le-Hang [1 ]
Li, Xiao-Long [1 ]
Zhao, Chong-Ke [1 ]
Li, Ming-Xu [1 ]
Wang, Ling [2 ]
Liu, Xin-Ying [2 ]
Xu, Hui-Xiong [1 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Ultrasound Res & Educ Inst,Dept Med Ultrasound, 301 Yanchangzhong Rd, Shanghai 200072, Peoples R China
[2] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Nephrol & Rheumatol, 301 Yanchangzhong Rd, Shanghai 200072, Peoples R China
关键词
Musculoskeletal system; Gout; Ultrasonography; Elastic modulus; Elastography; AMERICAN-COLLEGE; DIAGNOSIS; ARTHRITIS; LESIONS; ULTRASONOGRAPHY; CLASSIFICATION; HYPERURICEMIA; RELIABILITY; CRITERIA; TISSUE;
D O I
10.1007/s00330-018-5529-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesTo evaluate the value of ultrasound (US) in differentiating the acute phase of gout from the intercritical phase, particularly using shear wave elastography (SWE).Methods57 gout patients were prospectively enrolled and divided into acute phase and intercritical phase groups. The patients underwent US and SWE examinations for the first metatarsophalangeal joints with the same protocol. Maximum synovial thickness was measured. US features were reviewed by two radiologists independently. The maximum (E-max) and mean (E-mean) elastic moduli of synovium were calculated. Diagnostic performances of US, SWE and combined US and SWE were evaluated.ResultsUS findings demonstrated that the colour Doppler flow signal grade in the acute phase was higher than that in the intercritical phase (p = 0.001), whereas no differences were found for B-mode US features between the two groups (all p > 0.05). For SWE, E-max and E-mean were significantly higher in the intercritical phase than in the acute phase (both p < 0.001). The areas under the receiver operating characteristic curve (AUROCs) were 0.494-0.553 for B-mode US, 0.735 for colour Doppler US (CDUS), 0.887 for E-max and 0.882 for E-mean. The combination of CDUS and SWE increased the AUROC, sensitivity and accuracy significantly in comparison with CDUS alone (all p < 0.001). However, the combined set did not show stronger diagnostic performance in comparison with SWE alone.ConclusionSWE increases the diagnostic performance in differentiating the acute phase of gout from the intercritical phase in comparison with conventional US.Key Points center dot Colour Doppler flow signal grade is higher in acute phase of gout than in intercritical phase.center dot SWE demonstrates that synovium stiffness is higher in intercritical phase of gout than in acute phase.center dot SWE increases diagnostic performance in differentiating acute phase of gout from intercritical phase in comparison with conventional US.
引用
收藏
页码:5316 / 5327
页数:12
相关论文
共 50 条
  • [41] Evaluation of Main Lacrimal Gland through Shear-wave Ultrasound Elastography in Patients with Low Schirmer Value
    Yilmaz, Hakan
    Gunes, Irfan Botan
    CURRENT MEDICAL IMAGING, 2024, 20
  • [42] Efficacy of Ultrasound and Shear Wave Elastography for the Diagnosis of Breast Cancer-Related Lymphedema
    Polat, Ahmet Veysel
    Ozturk, Mesut
    Polat, Ayfer Kamali
    Karabacak, Ufuk
    Bekci, Tumay
    Murat, Naci
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (04) : 795 - 803
  • [43] Phase Aberration in Shear Wave Dispersion Ultrasound Vibrometry
    Shi, Yan
    Xie, Hua
    Shamdasani, Vijay
    Fraser, John
    Robert, Jean-Luc
    Zhou, Shiwei
    Urban, Matthew W.
    Chen, Shigao
    Greenleaf, James F.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2408 - 2411
  • [44] Ultrasound Shear Wave Elastography and Shear Wave Dispersion: Correlation with Histopathological Changes in Autoimmune Hepatitis Patients
    Hazzan, Rawi
    Regev-Sadeh, Tor
    Dola, Tamar
    Shemer-Shamay, Hila
    Umansky, Alona
    Zigmond, Ehud
    Neeman, Ziv
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2025, 51 (05) : 823 - 829
  • [45] Statistical and Texture Descriptors of Symptomatic Plantar Fasciitis Using Ultrasound Shear Wave Elastography
    Zhang, Hongmei
    Xu, Lei
    Liu, Zhihui
    Lu, Shukuan
    Yin, Jichao
    Tian, Sibo
    Yang, Xiaofeng
    Wan, Mingxi
    IEEE ACCESS, 2020, 8 : 120146 - 120159
  • [46] The Role of Shear Wave Elastography in Differentiating Idiopathic Granulomatous Mastitis From Breast Cancer
    Makal, Gul Bora
    Guvenc, Inanc
    ACADEMIC RADIOLOGY, 2021, 28 (03) : 339 - 344
  • [47] Three-dimensional shear-wave elastography for differentiating benign and malignant breast lesions: comparison with two-dimensional shear-wave elastography
    Youk, Ji Hyun
    Gweon, Hye Mi
    Son, Eun Ju
    Chung, Jin
    Kim, Jeong-Ah
    Kim, Eun-kyung
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1519 - 1527
  • [48] Utility of shear wave-based ultrasound elastography in chronic kidney disease and related pathological quantitative analysis
    Wu, Jingping
    Li, Guanghan
    Liu, Jian
    Sun, Weiliang
    Liu, Jiang
    Zou, Guming
    Lu, Haitao
    Zheng, Min
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5625 - 5633
  • [49] The evaluation of retrobulbar fat tissue in Graves' orbitopathy with shear-wave ultrasound elastography
    Gunes, Irfan Botan
    Yilmaz, Hakan
    Onal, Eda Demir
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [50] Comparison of shear wave elastography with gray-scale USG and CT for quantitative evaluation of rectus femoris muscle
    Yi, Jisook
    Cha, Jang Gyu
    Hahn, Seok
    JOURNAL OF CLINICAL ULTRASOUND, 2023, 51 (04) : 703 - 710