The SMILES prosthesis in salvage revision knee surgery

被引:17
作者
Back, D. L.
David, L. [1 ]
Hilton, A.
Blunn, G. [2 ]
Briggs, T. W. R. [1 ]
Cannon, S. R. [1 ]
机构
[1] Royal Natl Orthopaed Hosp, Stanmore HA7 4LP, Middx, England
[2] Univ London, Dept Biomed Engn, London WC1E 7HU, England
关键词
revision knee surgery; hinged prosthesis; salvage;
D O I
10.1016/j.knee.2007.09.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Revision total knee arthroplasty using a second generation modular rotating hinge design was done on thirty two knees in 30 patients over an 8-year period. Twenty-nine knees in 29 patients were followed up for 4.5-11 years (mean, 58 months). Four prostheses failed and two patients had died and one patient was lost to followup. Indications for revision were recurrent sepsis (five knees), component failure (four knees), ligamentous instability (two knees), aseptic loosening (10 knees), fracture (six knees), and gross bone loss (five knees). Early results have demonstrated improvement in both the Knee Society knee and function Scores and range of movement. The Knee Society knee score improved from 26 preoperatively to 68 postoperatively. The function score improved from 27 preoperatively to 75 postoperatively. One patient had evidence of aseptic loosening on radiographs, and the patellofemoral complication rate was low at 6%. This short-term clinical and radiographic review has demonstrated encouraging results in the use of a custom-made second generation rotating hinge component when used in revision knee surgery. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 44
页数:5
相关论文
共 32 条
[1]   Mid-term results of an AGC total knee arthroplasty system survival and function analysis -: 2-to 8-year follow-up results [J].
Alemparte, J ;
Cabezas, A ;
Azocar, O ;
Hernández, R ;
Acevedo, M .
JOURNAL OF ARTHROPLASTY, 2003, 18 (04) :420-425
[2]   The Kinemax total knee arthroplasty - Nine years' experience [J].
Back, DL ;
Cannon, SR ;
Hilton, A ;
Bankes, MJK ;
Briggs, TWR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (03) :359-363
[3]  
Barrack RL, 2001, CLIN ORTHOP RELAT R, P292
[4]   The use of a modular rotating hinge component in salvage revision total knee arthroplasty [J].
Barrack, RL ;
Lyons, TR ;
Ingraham, RQ ;
Johnson, JC .
JOURNAL OF ARTHROPLASTY, 2000, 15 (07) :858-866
[5]  
Benson ER, 1998, ORTHOPEDICS, V21, P875
[6]  
Cameron HU, 1997, CAN J SURG, V40, P278
[7]   The use of structural allograft for uncontained defects in revision total knee arthroplasty - A minimum five-year review [J].
Clatworthy, MG ;
Ballance, J ;
Brick, GW ;
Chandler, HP ;
Gross, AE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (03) :404-411
[8]  
CUCKLER JM, 1995, ORTHOPEDICS, V18, P932
[9]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, V248, P86
[10]  