Influence of implant connection on the stress distribution in restorations performed with hybrid abutments

被引:8
作者
Tribst, J. P. M. [1 ]
Dal Piva, A. M. O. [1 ]
Anami, L. C. [2 ]
Borges, A. L. S. [1 ]
Bottino, M. A. [1 ]
机构
[1] Sao Paulo State Univ, Inst Sci & Technol, Dept Dent Mat & Prosthodont, UNESP, Sao Jose Dos Campos, SP, Brazil
[2] Univ Santo Amaro, Dept Dent, Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental implants; Dental implant-abutment design; Finite element analysis; FRACTURE-RESISTANCE; SUPPORTED PROSTHESES; SINGLE CROWNS; ZIRCONIA; STRENGTH; BONE;
D O I
10.23805/JO.2019.11.03.08
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim This study evaluated the influence of prosthetic connection type (external hexagon [EH], internal hexagon [IH] and morse taper [MT]) on the stress distribution in an implant-supported prosthesis. Materials and methods Using modeling software, three sets were formed according to the prosthetic connection composed of ceramic crown, mesostructure, abutment, abutment screw, implant, cement layers and bone tissue. Solids were imported to the analysis software and bone model was fixed in the base. All materials were considered isotropic, linearly elastic and homogeneous. The static load (500 N, 30 degrees) was applied in the central fossa. Stress distribution data were obtained according to Von-Mises and microstrain criteria. Results The type of prosthetic connection influenced the stress distribution. The stresses for the IH and MT connections were concentrated on the implant and abutment; for EH at the implant, abutment screw, at the implant platform, and at the cement layer between abutment and mesostructure. There is lower influence for the crown and mesostructure, with more promising results for the MT connection. For the bone tissue, all connections showed the same strain pattern. Stress peaks of 148, 142 and 138 MPa in the implant, 134, 129 and 62 MPa in the screw, and 86, 118 and 131 MPa were observed respectively for EH, IH and MT. Conclusions The morse taper connection showed promising performance with lower stress concentration in the abutment screw, implant platform and cement layers.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 33 条
  • [1] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [2] The periodontal restorative interface: esthetic considerations
    Bennani, Vincent
    Ibrahim, Hadeel
    Al-Harthi, Latfiya
    Lyons, Karl M.
    [J]. PERIODONTOLOGY 2000, 2017, 74 (01) : 74 - 101
  • [3] Clinical Outcomes of Implant Abutments in the Anterior Region: A Systematic Review
    Bidra, Avinash S.
    Rungruanganunt, Patchanee
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2013, 25 (03) : 159 - 176
  • [4] Brodbeck Urs, 2003, J Esthet Restor Dent, V15, P10, DOI 10.1111/j.1708-8240.2003.tb00278.x
  • [5] In vitro evaluation of the implant abutment connection sealing capability of different implant systems
    Coelho, P. G.
    Sudack, P.
    Suzuki, M.
    Kurtz, K. S.
    Romanos, G. E.
    Silva, N. R. F. A.
    [J]. JOURNAL OF ORAL REHABILITATION, 2008, 35 (12): : 917 - 924
  • [6] Datte Carlos-Eduardo, 2018, J Clin Exp Dent, V10, pe439, DOI 10.4317/jced.54554
  • [7] Biomechanical Analysis of Implant-Supported Prostheses with Different Implant-Abutment Connections
    Dayrell, Andreza Costa
    Noritomi, Pedro Yoshito
    Ferreira Koyama Takahashi, Jessica Mie
    Xediek Consani, Rafael Leonardo
    Mesquita, Marcelo Ferraz
    Fernandes dos Santos, Mateus Bertolini
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (06) : 621 - 623
  • [8] Biomechanical Effect of Prosthetic Connection and Implant Body Shape in Low-Quality Bone of Maxillary Posterior Single Implant-Supported Restorations
    de Andrade, Camila Lima
    Carvalho, Marco Aurelio
    Del Bel Cury, Altair Antoninha
    Sotto-Maior, Bruno Salles
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (04) : E92 - E97
  • [9] Effect of fatigue loading on the fracture strength and failure mode of lithium disilicate and zirconia implant abutments
    Elsayed, Adham
    Wille, Sebastian
    Al-Akhali, Majed
    Kern, Matthias
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (01) : 20 - 27
  • [10] Comparison of fracture strength and failure mode of different ceramic implant abutments
    Elsayed, Adham
    Wille, Sebastian
    Al-Akhali, Majed
    Kern, Matthias
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04) : 499 - 506