Effect of CAD-CAM tool deterioration on the trueness of ceramic restorations

被引:9
作者
Al Hamad, Khaled Q. [1 ]
Al Rashdan, Rama B.
Al Rashdan, Bashar A.
Al Quran, Firas A. [1 ]
机构
[1] Jordan Univ Sci & Technol, Fac Dent, Dept Prosthodont, Irbid, Jordan
关键词
CLINICAL-EVALUATION; CAD/CAM; MACHINABILITY; PROSTHESES; ROUGHNESS; ACCURACY; FIT;
D O I
10.1016/j.prosdent.2020.09.035
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Tools will gradually deteriorate with repetitive milling. However, tool lifetime can vary depending on the type of milling machine, the hardness of the ceramic material, and the size of the restoration. Studies evaluating the effect of tool deterioration on the trueness of milled restorations are lacking. Purpose. The purpose of this study was to evaluate the effect of tool deterioration on the trueness of milled restorations. Material and methods. A patient requiring a ceramic crown was recruited. Repetitive milling of zirconia crowns (inCoris TZI; Dentsply Sirona) with tungsten carbide rotary instruments and glass-ceramic crowns (VITABLOCS mark II; Vita Zahnfabrik) with diamond rotary instruments was performed by using a 5-axis milling machine (inLab MC X5; Dentsply Sirona) until the machine software program indicated replacing the largest tool. The percentage of deterioration for the largest tool was recorded before each milling. The trueness for different crown areas was evaluated by using a 3-dimensional evaluation software program (Geomagic Control X; 3D systems), and the crowns were clinically evaluated. The crowns were grouped into 4 quadrants as per the deterioration percentage. The Pearson correlation (r) between the deterioration percentage and trueness and linear contrast analysis (partial eta squared [i]) among the groups were performed. Results. Glass-ceramic crown areas had low correlation except for mesial (high, r=0.63, high, eta=0.37) and distal (medium, r=0.42, high, eta= 0.34) areas, whereas zirconia crowns had low correlation for inner and internal areas and medium to high correlation for mesial (r= -0.31, eta=0.33), distal (r= -0.53, eta=0.36), occlusal (r= -0.32, eta=0.164), external (r= 0.69, eta=0.52), and marginal (r= -0.44, eta=0.19) areas. Zirconia crowns had excellent marginal fit and occlusal contact and light to excellent proximal contact, whereas glass-ceramic crowns had excellent marginal fit, minor to major occlusal correction, and heavy proximal contact. Conclusions. The effect of tool deterioration on trueness depended on material type and crown area. Only proximal areas were affected in the glass-ceramic crowns, whereas external, proximal, occlusal, and marginal areas were affected in the zirconia crowns. Trueness did not necessarily reflect the clinical quality of the crown, as both crown types were clinically satisfactory. Although zirconia crowns were overmilled in comparison with the reference design and glass-ceramic crowns, they had better clinical quality.
引用
收藏
页码:635 / 644
页数:10
相关论文
共 25 条
[1]   Comparison of the Fit of Lithium Disilicate Crowns made from Conventional, Digital, or Conventional/Digital Techniques [J].
Al Hamad, Khaled Q. ;
Al Rashdan, Bashar A. ;
Al Omari, Wael M. ;
Baba, Nadim Z. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02) :E580-E586
[2]   A clinical study on the effects of cordless and conventional retraction techniques on the gingival and periodontal health [J].
Al Hamad, Khaled Q. ;
Azar, Wesam Z. ;
Alwaeli, Hayder A. ;
Said, Khalid N. .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2008, 35 (12) :1053-1058
[3]   Machinability of CAD-CAM materials [J].
Chavali, Ramakiran ;
Nejat, Amir H. ;
Lawson, Nathaniel C. .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02) :194-199
[4]   Trueness of the Inner Surface of Monolithic Crowns Fabricated by Milling of a Fully Sintered (Y, Nb)-TZP Block in Chairside CAD-CAM System for Single-visit Dentistry [J].
Cho, Jun-Ho ;
Yoon, Hyung-In ;
Han, Jung-Suk ;
Kim, Dae-Joon .
MATERIALS, 2019, 12 (19)
[5]  
Cohen J., 1988, STAT POWER ANAL BEHA, P75
[6]  
Corazza PH, 2015, AM J DENT, V28, P95
[7]   Newer vs. older CAD/CAM burs: Influence of bur experience on the fatigue behavior of adhesively cemented simplified lithium-disilicate glass-ceramic restorations [J].
de Andrade, Guilherme Schmitt ;
Diniz, Vandeberg ;
Datte, Carlos Eduardo ;
Rocha Pereira, Gabriel Kalil ;
Venturini, Andressa Bonin ;
Bastos Campos, Tiago Moreira ;
Amaral, Marina ;
Bottino, Marco Antonio ;
Valandro, Luiz Felipe ;
de Melo, Renata Marques .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 95 :172-179
[8]   Dimensional changes from the sintering process and fit of Y-TZP copings: Micro-CT analysis [J].
Edwards Rezende, Carlos Eduardo ;
Sanches Borges, Ana Flavia ;
Macedo, Rander Moreira ;
Rubo, Jose Henrique ;
Griggs, Jason Alan .
DENTAL MATERIALS, 2017, 33 (11) :E405-E413
[9]   The accuracy of clinician evaluation of interproximal contacts using different methods [J].
Hansen, Paul A. ;
Atwood, Ariel ;
Shanahan, Mallory ;
Beatty, Mark .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (02) :284-289
[10]  
Hickel R, 2007, J ADHES DENT, V9, P121