Triclosan in a sewage treatment process - balances and monitoring data

被引:231
作者
Bester, K [1 ]
机构
[1] Univ Dortmund, Inst Environm Res, D-44221 Dortmund, Germany
关键词
triclosan; wastewater; sewage treatment plant; balance;
D O I
10.1016/S0043-1354(03)00335-X
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In a German sewage treatment plant that processes 200,000m(3) wastewater per day, the concentrations of 2,4,4'trichloro, 2'-hydroxy-phenylether (triclosan) in the in-flowing (similar to1000ng l(-1)) as well as in the out-flowing water (similar to 50 ng l(-1)) are compared to the concentrations measured in sludge (1200 ng g(-1)). Considering the mass flow of water and sludge in the respective plant, balances including water and sludge are calculated. Thirty percent of the triclosan is sorbed with weak bonds to the sludge, while some amounts are sorbed as bound residues in the sludge. About 5% is dissolved in the out-flowing water. Thus most of the in-flowing material is not recovered as the parent compound but it is likely that it is transformed to other metabolites or unrecovered bound residues. These data are compared to the monitoring of sewage sludge of 20 different plants in this region, most of which are smaller, though. The concentrations found in these sludges vary from 1000-8000 ng g(-1). (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3891 / 3896
页数:6
相关论文