Evaluation of climatic zones and field study on thermal comfort for underground engineering in China during summer

被引:22
作者
Li, Yong [1 ,3 ]
Geng, Shibin [1 ]
Yuan, Yanping [2 ]
Wane, Jing [1 ]
Zhang, Xiaosong [3 ]
机构
[1] Army Engn Univ PLA, Nanjing 210007, Jiangsu, Peoples R China
[2] Southwest Jiao Tong Univ, Sch Mech Engn, Chengdu 610031, Sichuan, Peoples R China
[3] Southeast Univ, Nanjing 210007, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Climatic zones; Thermal comfort; Underground engineering; Neutral temperature; NATURALLY VENTILATED BUILDINGS; HOT-HUMID CLIMATES; HUMAN RESPONSES; INDOOR ENVIRONMENT; ENERGY-CONSUMPTION; RELATIVE-HUMIDITY; AIR-TEMPERATURE; OCCUPANTS; MODEL; PERFORMANCE;
D O I
10.1016/j.scs.2018.08.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The researches on thermal comfort for underground engineering are lacking in China. In this paper, ground temperature (T-g), ventilating sensible heat ratio (VSHR) of fresh air in 249 cities of different areas were calculated, and four climatic zones including Cold, Dry, Humid, Hot&Humid were established. Through field surveys from June 1 to September 30 during the period 2007-2015, larger amounts of measured data and 5862 effective questionnaires were obtained in non-air conditioned defense basement in the four climatic zones. Results showed that the mean thermal sensation (MTS) values did not agree with the values of PMV model. At the same operative temperature of 27 degrees C, the values of MTS were 0.53, 0.47, 0.32 and 0.0 in Cold, Dry, Humid and Hot&Humid climatic zone, respectively. When T-op was more than 26 degrees C, more than 84% of the occupants expect 'no change' in the four climatic zones, especially 91% in Hot&Humid zone. When relative humidity (RH) was more than 80%, most of the occupants' thermal acceptability (TA) was less than - 0.3. In addition, by using multiple regression techniques, the neutral temperature models were derived using the parameters of average outdoor temperature, T-g, RH and clothing value for different climatic zones.
引用
收藏
页码:421 / 431
页数:11
相关论文
共 61 条
[1]  
Adjali M.H., 1998, Building Services Engineering Research and Technology, V19, P111, DOI DOI 10.1177/014362449801900301
[2]   Three-dimensional earth-contact heat flows: A comparison of simulated and measured data for a buried structure [J].
Adjali, MH ;
Davies, M ;
Littler, J .
RENEWABLE ENERGY, 1998, 15 (1-4) :356-359
[3]   A guideline for assessing the suitability of earth-sheltered mass-housing in hot-arid climates [J].
Al-Temeemi, AA ;
Harris, DJ .
ENERGY AND BUILDINGS, 2004, 36 (03) :251-260
[4]  
[Anonymous], 2010, BUILT ENV
[5]  
[Anonymous], 2005, ERGONOMICS THERMAL E
[6]  
ASHRAE, 2013, 552013 ASHRAE REFR A
[7]   Heating energy consumption and resulting environmental impact of European apartment buildings [J].
Balaras, CA ;
Droutsa, K ;
Dascalaki, E ;
Kontoyiannidis, S .
ENERGY AND BUILDINGS, 2005, 37 (05) :429-442
[8]   Underground cellar thermal simulation: Definition of a method for modelling performance assessment based on experimental calibration [J].
Barbaresi, Alberto ;
Torreggiani, Daniele ;
Benni, Stefano ;
Tassinari, Patrizia .
ENERGY AND BUILDINGS, 2014, 76 :363-372
[9]   A breakdown of energy consumption in an underground station [J].
Casals, Miquel ;
Gangolells, Marta ;
Forcada, Nuria ;
Macarulla, Marcel ;
Giretti, Alberto .
ENERGY AND BUILDINGS, 2014, 78 :89-97
[10]   Thermal environment and human responses in underground shopping malls vs department stores in Japan [J].
Chun, CY ;
Tamura, A .
BUILDING AND ENVIRONMENT, 1998, 33 (2-3) :151-158