Cleaning and passivation of copper surfaces to remove surface radioactivity and prevent oxide formation

被引:41
作者
Hoppe, E. W. [1 ]
Seifert, A. [1 ]
Aalseth, C. E. [1 ]
Bachelor, P. P. [1 ]
Day, A. R. [1 ]
Edwards, D. J. [1 ]
Hossbach, T. W. [1 ]
Litke, K. E. [1 ]
McIntyre, J. I. [1 ]
Miley, H. S. [1 ]
Schulte, S. M. [1 ]
Smart, J. E. [1 ]
Warren, G. A. [1 ]
机构
[1] Pacific NW Natl Lab, Richland, WA 99352 USA
基金
美国能源部;
关键词
ultra-low background; surface contamination; surface preparation; surface passivation; high-purity copper; double-beta decay;
D O I
10.1016/j.nima.2007.04.101
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
High-purity copper is an attractive material for constructing ultra-low-background radiation measurement devices. Many low-background experiments using high-purity copper have indicated surface contamination emerges as the dominant background. Radon daughters plate out on exposed surfaces, leaving a residual 2 Pb-210 background that is difficult to avoid. Dust is also a problem; even under cleanroom conditions, the amount of U and Th deposited on surfaces can represent the largest remaining background. To control these backgrounds, a copper cleaning chemistry has been developed. Designed to replace an effective, but overly aggressive concentrated nitric acid etch, this peroxide-based solution allows for a more controlled cleaning of surfaces. The acidified hydrogen peroxide solution will generally target the Cu+/Cu2+ species which are the predominant surface participants, leaving the bulk of copper metal intact. This preserves the critical tolerances of parts and eliminates significant waste disposal issues. Accompanying passivation chemistry has also been developed that protects copper surfaces from oxidation. Using a high-activity polonium surface spike, the most difficult-to-remove daughter isotope of radon, the performance of these methods are quantified. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:486 / 489
页数:4
相关论文
共 4 条
[1]  
Aalseth CE, 2005, AIP CONF PROC, V785, P170, DOI 10.1063/1.2060468
[2]   LOW-BACKGROUND GERMANIUM SPECTROMETRY - THE BOTTOM LINE 3 YEARS LATER [J].
BRODZINSKI, RL ;
MILEY, HS ;
REEVES, JH ;
AVIGNONE, FT .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 193 (01) :61-70
[3]   FURTHER REDUCTION OF RADIOACTIVE BACKGROUNDS IN ULTRASENSITIVE GERMANIUM SPECTROMETERS [J].
BRODZINSKI, RL ;
MILEY, HS ;
REEVES, JH ;
AVIGNONE, FT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (02) :337-342
[4]   CUORICINO status and CUORE prospects [J].
Brofferio, C ;
Ardito, R ;
Arnaboldi, C ;
Artusa, DR ;
Avignone, FT ;
Balata, M ;
Bandac, I ;
Barucci, M ;
Beeman, JW ;
Bellini, F ;
Bucci, C ;
Capelli, S ;
Capozzi, F ;
Carbone, L ;
Cebrian, S ;
Cosmelli, C ;
Cremonesi, O ;
Creswick, RJ ;
de Waard, A ;
Dolinski, M ;
Farach, HA ;
Ferroni, F ;
Fiorini, E ;
Frossati, G ;
Gargiulo, C ;
Guardincerri, E ;
Giuliani, A ;
Gorla, P ;
Gutierrez, TD ;
Haller, EE ;
Irastorza, IG ;
Longo, E ;
Maier, G ;
Maruyama, R ;
McDonald, RJ ;
Morganti, S ;
Nisi, S ;
Norman, EB ;
Nucciotti, A ;
Olivieri, E ;
Ottonello, P ;
Pallavicini, M ;
Palmieri, V ;
Pasca, E ;
Pavan, M ;
Pedretti, M ;
Pessina, G ;
Pirro, S ;
Previtali, E ;
Quiter, B .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2005, 145 :268-271