Accuracy of two deep learning-based reconstruction methods compared with an adaptive statistical iterative reconstruction method for solid and ground-glass nodule volumetry on low-dose and ultra-low-dose chest computed tomography: A phantom study

被引:8
|
作者
Kim, Cherry [1 ]
Kwack, Thomas [1 ]
Kim, Wooil [2 ]
Cha, Jaehyung [3 ]
Yang, Zepa [4 ]
Yong, Hwan Seok [5 ]
机构
[1] Ansan Hosp, Korea Univ Coll Med, Dept Radiol, Ansan, Gyeonggi, South Korea
[2] Univ Virginia Hlth Syst, Dept Radiol & Med Imaging, Charlottesville, VA USA
[3] Ansan Hosp, Korea Univ Coll Med, Med Sci Res Ctr, Ansan, Gyeonggi, South Korea
[4] Guro Hosp, Korea Univ Coll Med, Biomed Res Ctr, Seoul, South Korea
[5] Guro Hosp, Korea Univ Coll Med, Dept Radiol, Seoul, South Korea
来源
PLOS ONE | 2022年 / 17卷 / 06期
基金
新加坡国家研究基金会;
关键词
FILTERED BACK-PROJECTION; IMAGE QUALITY; CT; SETTINGS;
D O I
10.1371/journal.pone.0270122
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
No published studies have evaluated the accuracy of volumetric measurement of solid nodules and ground-glass nodules on low-dose or ultra-low-dose chest computed tomography, reconstructed using deep learning-based algorithms. This is an important issue in lung cancer screening. Our study aimed to investigate the accuracy of semiautomatic volume measurement of solid nodules and ground-glass nodules, using two deep learning-based image reconstruction algorithms (Truefidelity and ClariCT.AI), compared with iterative reconstruction (ASiR-V) in low-dose and ultra-low-dose settings. We performed computed tomography scans of solid nodules and ground-glass nodules of different diameters placed in a phantom at four radiation doses (120 kVp/220 mA, 120 kVp/90 mA, 120 kVp/40 mA, and 80 kVp/40 mA). Each scan was reconstructed using Truefidelity, ClariCT.AI, and ASiR-V. The solid nodule and ground-glass nodule volumes were measured semiautomatically. The gold-standard volumes could be calculated using the diameter since all nodule phantoms are perfectly spherical. Subsequently, absolute percentage measurement errors of the measured volumes were calculated. Image noise was also calculated. Across all nodules at all dose settings, the absolute percentage measurement errors of Truefidelity and ClariCT.AI were less than 11%; they were significantly lower with Truefidelity or ClariCT.AI than with ASiR-V (all P<0.05). The absolute percentage measurement errors for the smallest solid nodule (3 mm) reconstructed by Truefidelity or ClariCT.AI at all dose settings were significantly lower than those of this nodule reconstructed by ASiR-V (all P<0.05). Furthermore, the lowest absolute percentage measurement errors for ground-glass nodules were observed with Truefidelity or ClariCT.AI at all dose settings. The absolute percentage measurement errors for ground-glass nodules reconstructed with Truefidelity at ultra-low-dose settings were significantly lower than those of all sizes of ground-glass nodules reconstructed with ASiR-V (all P<0.05). Image noise was lowest with Truefidelity (all P<0.05). In conclusion, the deep learning-based algorithms were more accurate for volume measurements of both solid nodules and ground-glass nodules than ASiR-V at both low-dose and ultra-low-dose settings.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Pulmonary nodule volumetric accuracy of a deep learning-based reconstruction algorithm in low-dose computed tomography: A phantom study
    Watanabe, Shota
    Sakaguchi, Kenta
    Kitaguchi, Shigetoshi
    Ishii, Kazunari
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 1 - 9
  • [2] Usefulness of model-based iterative reconstruction in semi-automatic volumetry for ground-glass nodules at ultra-low-dose CT: a phantom study
    Maruyama S.
    Fukushima Y.
    Miyamae Y.
    Koizumi K.
    Radiological Physics and Technology, 2018, 11 (2) : 235 - 241
  • [3] Radiation dose reduction using deep learning-based image reconstruction for a low-dose chest computed tomography protocol: a phantom study
    Jung, Yunsub
    Hur, Jin
    Han, Kyunghwa
    Imai, Yasuhiro
    Hong, Yoo Jin
    Im, Dong Jin
    Lee, Kye Ho
    Desnoyers, Melissa
    Thomsen, Brian
    Shigemasa, Risa
    Um, Kyounga
    Jang, Kyungeun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1937 - +
  • [4] Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study
    Doo, K. W.
    Kang, E-Y
    Yong, H. S.
    Woo, O. H.
    Lee, K. Y.
    Oh, Y-W
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1041):
  • [5] Deep-learning reconstruction for ultra-low-dose lung CT: Volumetric measurement accuracy and reproducibility of artificial ground-glass nodules in a phantom study
    Mikayama, Ryoji
    Shirasaka, Takashi
    Kojima, Tsukasa
    Sakai, Yuki
    Yabuuchi, Hidetake
    Kondo, Masatoshi
    Kato, Toyoyuki
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1130):
  • [6] Ultra-low-dose CT with model-based iterative reconstruction (MBIR): detection of ground-glass nodules in an anthropomorphic phantom study
    Rampinelli, Cristiano
    Origgi, Daniela
    Vecchi, Vittoria
    Funicelli, Luigi
    Raimondi, Sara
    Deak, Paul
    Bellomi, Massimo
    RADIOLOGIA MEDICA, 2015, 120 (07): : 611 - 617
  • [7] Ultra-low-dose CT with model-based iterative reconstruction (MBIR): detection of ground-glass nodules in an anthropomorphic phantom study
    Cristiano Rampinelli
    Daniela Origgi
    Vittoria Vecchi
    Luigi Funicelli
    Sara Raimondi
    Paul Deak
    Massimo Bellomi
    La radiologia medica, 2015, 120 : 611 - 617
  • [8] Model-based iterative reconstruction in ultra-low-dose pediatric chest CT: comparison with adaptive statistical iterative reconstruction
    Kim, Hae Jin
    Yoo, So-Young
    Jeon, Tae Yeon
    Kim, Ji Hye
    CLINICAL IMAGING, 2016, 40 (05) : 1018 - 1022
  • [9] Ultra-low-dose chest computed tomography with model-based iterative reconstruction in the analysis of solid pulmonary nodules: A prospective study
    O'Regan, Patrick W.
    Harold-Barry, Antonia
    O'Mahony, Alexander T.
    Crowley, Claire
    Joyce, Stella
    Moore, Niamh
    O'Connor, Owen J.
    Henry, Michael T.
    Ryan, David J.
    Maher, Michael M.
    WORLD JOURNAL OF RADIOLOGY, 2024, 16 (11):
  • [10] Detection of ground-glass opacities by use of hybrid iterative reconstruction (iDose) and low-dose 256-section computed tomography: A phantom study
    Higuchi K.
    Nagao M.
    Matsuo Y.
    Sunami S.
    Kamitani T.
    Jinnouchi M.
    Yonezawa M.
    Yamasaki Y.
    Yabuuchi H.
    Hatkenaka M.
    Honda H.
    Radiological Physics and Technology, 2013, 6 (2) : 299 - 304