Combined helium-3/proton magnetic resonance imaging measurement of ventilated lung volumes in smokers compared to never-smokers

被引:147
作者
Woodhouse, N
Wild, JM
Paley, MNJ
Fichele, S
Said, Z
Swift, AJ
van Beek, EJR
机构
[1] Univ Sheffield, Royal Hallamshire Hosp, Unit Acad Radiol, Sheffield S10 2JF, S Yorkshire, England
[2] Univ Iowa Hosp & Clin, Carver Coll Med, Dept Radiol, Iowa City, IA 52242 USA
关键词
hyperpolarized helium-3 MRI; lung volumes; smoking; image segmentation;
D O I
10.1002/jmri.20290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To use a combination of helium-3 (3-He) magnetic resonance imaging (MRI) and proton single-shot fast spin echo (SSFSE) to compare ventilated lung volumes in groups of healthy smokers diagnosed with moderate chronic obstructive pulmonary disease (COPD), and never smokers. Materials and Methods: All study participants were assessed with spirometry prior to imaging. 3-He images were collected during an arrested breath hold, after inhaling a mixture of 200 mL of hyperpolarized 3-He/800 mL of N-2. Proton SSFSE images were acquired after inhaling 1 liter of room air. The ventilated volume for each study participant was calculated from 3-He images, and a ratio was calculated to give a percentage ventilated lung volume. Results: Never-smokers exhibited 90% mean ventilated volume. The mean ventilated lung volumes for healthy smokers and smokers diagnosed with COPD were 75.2% and 67.6%, respectively. No correlation with spirometry was demonstrated for either of the smoking groups. Conclusion: Combined 3-He/Proton SSFSE MRI of the lungs is a noninvasive method, using nonionizing radiation, which demonstrates ventilated airspaces and enables the calculation of ventilated lung volumes. This method appears to be sensitive to early obstructive changes in the lungs of smokers.
引用
收藏
页码:365 / 369
页数:5
相关论文
共 11 条
[1]   Cystic fibrosis:: Combined hyperpolarized 3He-enhanced and conventional proton MR imaging in the lung -: Preliminary observations [J].
Donnelly, LF ;
MacFall, JR ;
McAdams, HP ;
Majure, JM ;
Smith, J ;
Frush, DP ;
Bogonad, P ;
Charles, HC ;
Ravin, CE .
RADIOLOGY, 1999, 212 (03) :885-889
[2]   MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence [J].
Hatabu, H ;
Gaa, J ;
Tadamura, E ;
Edinburgh, KJ ;
Stock, KW ;
Garpestad, E ;
Edelman, RR .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 29 (02) :152-159
[3]   Assessment of lung ventilation by MR imaging: current status and future perspectives [J].
Kauczor, HU ;
Hanke, A ;
van Beek, EJR .
EUROPEAN RADIOLOGY, 2002, 12 (08) :1962-1970
[4]   MRI of the pulmonary parenchyma [J].
Kauczor, HU ;
Kreitner, KF .
EUROPEAN RADIOLOGY, 1999, 9 (09) :1755-1764
[5]   Volumetry of ventilated airspaces by 3He MRI preliminary results [J].
Kauczor, HU ;
Markstaller, K ;
Puderbach, M ;
Lill, J ;
Eberle, B ;
Hanisch, G ;
Grossmann, T ;
Heussel, CP ;
Schreiber, W ;
Thelen, M .
INVESTIGATIVE RADIOLOGY, 2001, 36 (02) :110-114
[6]   3He-MRI-based vs. conventional determination of lung volumes in patients after unilateral lung transplantation:: a new approach to regional spirometry [J].
Markstaller, K ;
Kauczor, HU ;
Puderbach, M ;
Mayer, E ;
Viallon, M ;
Gast, K ;
Weiler, N ;
Thelen, M ;
Eberle, B .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2002, 46 (07) :845-852
[7]   MRI of the lungs using hyperpolarized noble gases [J].
Möller, HE ;
Chen, XJ ;
Saam, B ;
Hagspiel, KD ;
Johnson, GA ;
Altes, TA ;
de Lange, EE ;
Kauczor, HU .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1029-1051
[8]   Estimation of gas and tissue lung volumes by MRI: Functional approach of lung imaging [J].
Qanadli, SD ;
Orvoen-Frija, E ;
Lacombe, P ;
Di Paola, R ;
Bittoun, J ;
Frija, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (05) :743-748
[9]   Assessment and compensation of susceptibility artifacts in gradient echo MRI of hyperpolarized 3He gas [J].
Wild, JM ;
Fichele, S ;
Woodhouse, N ;
Paley, MNJ ;
Swift, A ;
Kasuboski, L ;
van Beek, EJR .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (02) :417-422
[10]   k-space filtering in 2D gradient-echo breath-hold hyperpolarized 3He MRI:: Spatial resolution and signal-to-noise ratio considerations [J].
Wild, JM ;
Paley, MNJ ;
Viallon, M ;
Schreiber, WG ;
van Beek, EJR ;
Griffiths, PD .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :687-695