Comparison of FDG PET and positron coincidence detection imaging using a dual-head gamma camera with 5/8-inch NaI(Tl) crystals in patients with suspected body malignancies

被引:44
作者
Boren, EL [1 ]
Delbeke, D [1 ]
Patton, JA [1 ]
Sandler, MP [1 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nucl Med Sect, Nashville, TN 37232 USA
关键词
emission computed tomography; fluorine; neoplasms;
D O I
10.1007/s002590050401
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare the diagnostic accuracy of fluorine-18 fluorodeoxyglucose (FDG) images obtained with (a) a dual-head coincidence gamma camera (DHC) equipped with 5/8-inch-thick NaI(Tl) crystals and parallel slit collimators and (b) a dedicated positron emission tomograph (PET) in a series of 28 patients with known or suspected malignancies. Twenty-eight patients with known or suspected malignancies underwent whole-body FDG PET imaging (Siemens, ECAT 933) after injection of approximately 10 mCi of F-18-FDG. FDG DHC images were then acquired for 30 min over the regions of interest using a dual-head gamma camera (VariCam, Elscint). The images were reconstructed in the normal mode, using photopeak/photopeak, photopeak/Compton, and Compton/photopeak coincidence events. FDG PET imaging found 45 lesions ranging in size from 1 cm to 7 cm in 28 patients. FDG DHC imaging detected 35/45 (78%) of these lesions. Among the ten lesions not seen with FDG DHC imaging, eight were less than 1.5 cm in size, and two were located centrally within the abdomen suffering from marked attenuation effects. The lesions were classified into three categories: thorax (n=24), liver (n=12), and extrahepatic abdominal (n=9), FDG DHC imaging identified 100% of lesions above 1.5 cm in the thorax group and 78% of those below 1.5 cm, for an overall total of 83%. FDG DHC imaging identified 100% of lesions above 1.5 cm, in the liver and 43% of lesions below 1.5 cm, for an overall total of 67%. FDG DHC im aging identified 78% of lesions above 1.5 cm in the extrahepatic abdominal group. There were no lesions below 1.5 cm in this group. FDG coincidence imaging using a dual-head gamma camera detected 90% of lesions greater than 1.5 cm. These data suggest that DHC imaging can be used clinically in well-defined diagnostic situations to differentiate benign from malignant lesions.
引用
收藏
页码:379 / 387
页数:9
相关论文
共 16 条
  • [1] BURT RW, 1995, J NUCL MED, V36, P176
  • [2] DELBEKE D, 1995, J NUCL MED, V36, P2110
  • [3] Delbeke D, 1999, J NUCL MED, V40, P110
  • [4] TECHNOLOGY FOR FDG SPECT WITH A RELATIVELY INEXPENSIVE GAMMA-CAMERA - WORK-IN-PROGRESS
    DRANE, WE
    ABBOTT, FD
    NICOLE, MW
    MASTIN, ST
    KUPERUS, JH
    [J]. RADIOLOGY, 1994, 191 (02) : 461 - 465
  • [5] ELEVATED LEVELS OF GLUCOSE-TRANSPORT AND TRANSPORTER MESSENGER-RNA ARE INDUCED BY RAS OR SRC ONCOGENES
    FLIER, JS
    MUECKLER, MM
    USHER, P
    LODISH, HF
    [J]. SCIENCE, 1987, 235 (4795) : 1492 - 1495
  • [6] TRIPLE-HEAD SPECT WITH 2-[FLUORINE-18]FLUORO-2-DEOXY-D-GLUCOSE (FDG) - INITIAL EVALUATION IN ONCOLOGY AND COMPARISON WITH FDG PET
    MACFARLANE, DJ
    COTTON, L
    ACKERMANN, RJ
    MINN, H
    FICARO, EP
    SHREVE, PD
    WAHL, RL
    [J]. RADIOLOGY, 1995, 194 (02) : 425 - 429
  • [7] Detection of malignancies with SPECT versus PET, with 2-[fluorine-18]fluoro-2-deoxy-D-glucose
    Martin, WH
    Delbeke, D
    Patton, JA
    Sandler, MP
    [J]. RADIOLOGY, 1996, 198 (01) : 225 - 231
  • [8] MARTIN WH, 1995, J NUCL MED, V36, P988
  • [9] PHYSICOCHEMICAL PROPERTIES AND ISOENZYME COMPOSITION OF HEXOKINASE FROM NORMAL AND MALIGNANT HUMAN TISSUES
    MONAKHOV, NK
    NEISTADT, EL
    SHAVLOVSKIL, MM
    SHVARTSMAN, AL
    NEIFAKH, SA
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1978, 61 (01): : 27 - 34
  • [10] EVALUATION OF MYOCARDIAL-ISCHEMIA USING A REST METABOLISM STRESS PERFUSION PROTOCOL WITH F-18 DEOXYGLUCOSE TECHNETIUM-99M MIDI AND DUAL-ISOTOPE SIMULTANEOUS-ACQUISITION SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY
    SANDLER, MP
    VIDELEFSKY, S
    DELBEKE, D
    PATTON, JA
    MEYEROWITZ, C
    MARTIN, WH
    OHANA, I
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (04) : 870 - 878