A multicentered evaluation of ablation at higher power guided by ablation index: Establishing ablation targets for pulmonary vein isolation

被引:88
|
作者
Dhillon, Gurpreet [1 ]
Ahsan, Syed [1 ]
Honarbakhsh, Shohreh [1 ]
Lim, Wei [1 ]
Baca, Marco [1 ]
Graham, Adam [1 ]
Srinivasan, Neil [1 ]
Sawhney, Vinit [1 ]
Sporton, Simon [1 ]
Schilling, Richard J. [1 ]
Chow, Anthony [1 ]
Ginks, Matthew [2 ]
Sohal, Manav [3 ,4 ]
Gallagher, Mark M. [3 ,4 ]
Hunter, Ross J. [1 ]
机构
[1] Barts Hlth NHS Trust, St Bartholomews Hosp, Barts Heart Ctr, Dept Cardiac Electrophysiol, London EC1A 7BE, England
[2] Oxford Univ Hosp NHS Fdn Trust, John Radcliffe Hosp, Oxford Heart Ctr, Dept Cardiol, Oxford, England
[3] St George Hosp, Dept Cardiol, London, England
[4] St Anthony Hosp, Dept Cardiol, Sutton, Surrey, England
关键词
ablation index; atrial fibrillation; pulmonary vein isolation; CONTACT FORCE; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; CATHETER ABLATION; RECONNECTION; TRIAL;
D O I
10.1111/jce.13813
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. Methods Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. Results One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 omega, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group (P = 0.186). Conclusion High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 50 条
  • [41] Performance of the ablation index during pulmonary vein isolation: periprocedural data from a multicenter registry
    Nigar Z. Gasimova
    Anatoly A. Nechepurenko
    Evgeny B. Kropotkin
    Eduard A. Ivanitsky
    Grigorii V. Kolunin
    Dmitry A. Shavshin
    Bor Antolic
    Elena A. Artyukhina
    Ayan S. Abdrakhmanov
    Konstantin S. Korolev
    Dmitry S. Lebedev
    Evgeny N. Mikhaylov
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 167 - 177
  • [42] Performance of the ablation index during pulmonary vein isolation: periprocedural data from a multicenter registry
    Gasimova, Nigar Z.
    Nechepurenko, Anatoly A.
    Kropotkin, Evgeny B.
    Ivanitsky, Eduard A.
    Kolunin, Grigorii, V
    Shavshin, Dmitry A.
    Antolic, Bor
    Artyukhina, Elena A.
    Abdrakhmanov, Ayan S.
    Korolev, Konstantin S.
    Lebedev, Dmitry S.
    Mikhaylov, Evgeny N.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (01) : 167 - 177
  • [43] Comparison of Cryoballoon and Ablation Index-Guided Radiofrequency Ablation in Paroxysmal Atrial Fibrillation
    Bocz, Botond
    Debreceni, Dorottya
    Janosi, Kristof-Ferenc
    Torma, Dalma
    Kupo, Peter
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (06)
  • [44] Statistical Model of Paroxysmal Atrial Fibrillation Catheter Ablation Targets for Pulmonary Vein Isolation
    Al-Agamy, Ahmad
    Karim, Rashed
    Arujuna, Aruna
    Harrison, James L.
    Williams, Steven E.
    Rhode, Kawal S.
    van Assen, Hans C.
    STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART: IMAGING AND MODELLING CHALLENGES, 2015, 8896 : 221 - 230
  • [45] Safety and efficacy of atrial fibrillation ablation guided by Ablation Index module
    Francesco Solimene
    Vincenzo Schillaci
    Gergana Shopova
    Francesco Urraro
    Alberto Arestia
    Assunta Iuliano
    Fabio Maresca
    Alessia Agresta
    Vincenzo La Rocca
    Antonio De Simone
    Giuseppe Stabile
    Journal of Interventional Cardiac Electrophysiology, 2019, 54 : 9 - 15
  • [46] Tailored ablation index for pulmonary vein isolation according to wall thickness within the ablation circle
    Wang, Yong
    Zhou, Genqing
    Chen, Songwen
    Wei, Yong
    Lu, Xiaofeng
    Xu, Juan
    Wu, Xiaoyu
    Liu, Shaowen
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (04): : 575 - 585
  • [47] Impact of ablation index settings on pulmonary vein reconnection
    A. Lepillier
    T. Strisciuglio
    E. De Ruvo
    M. Scaglione
    M. Anselmino
    F. A. Sebag
    D. Pecora
    M. M. Gallagher
    M. Rillo
    G. Viola
    E. Pisanò
    S. Abbey
    F. Lamberti
    A. Pani
    G. Zucchelli
    G. Sgarito
    A. De Simone
    E. Bertaglia
    F. Solimene
    Giuseppe Stabile
    Journal of Interventional Cardiac Electrophysiology, 2022, 63 : 133 - 142
  • [48] Efficacy and safety of ablation index-guided catheter ablation for atrial fibrillation: an updated meta-analysis
    Ioannou, Adam
    Papageorgiou, Nikolaos
    Lim, Wei Yao
    Wongwarawipat, Tanakal
    Hunter, Ross J.
    Dhillon, Gurpreet
    Schilling, Richard J.
    Creta, Antonio
    El Haddad, Milad
    Duytschaever, Matthias
    Hussein, Ahmed
    Dhiraj, Gupta
    Ahsan, Syed
    Providencia, Rui
    EUROPACE, 2020, 22 (11): : 1659 - 1671
  • [49] Assessment of the need of a waiting period after pulmonary vein isolation with the ablation index software
    Sousa, Pedro A.
    Barra, Sergio
    Adao, Luis
    Primo, Joao
    Khoueiry, Ziad
    Puga, Luis
    Lebreiro, Ana
    Fonseca, Paulo
    Lagrange, Philippe
    Goncalves, Lino
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (08) : 1725 - 1733
  • [50] One-year outcome and durability of pulmonary vein isolation after prospective use of ablation index for catheter ablation in patients with persistent atrial fibrillation
    Reinsch, Nico
    Fueting, Anna
    Buchholz, Jochen
    Ruprecht, Ute
    Holzendorf, Volker
    Buschmeier, Felix
    Kaelsch, Hagen
    Neven, Kars
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 143 - 151