A multicentered evaluation of ablation at higher power guided by ablation index: Establishing ablation targets for pulmonary vein isolation

被引:88
|
作者
Dhillon, Gurpreet [1 ]
Ahsan, Syed [1 ]
Honarbakhsh, Shohreh [1 ]
Lim, Wei [1 ]
Baca, Marco [1 ]
Graham, Adam [1 ]
Srinivasan, Neil [1 ]
Sawhney, Vinit [1 ]
Sporton, Simon [1 ]
Schilling, Richard J. [1 ]
Chow, Anthony [1 ]
Ginks, Matthew [2 ]
Sohal, Manav [3 ,4 ]
Gallagher, Mark M. [3 ,4 ]
Hunter, Ross J. [1 ]
机构
[1] Barts Hlth NHS Trust, St Bartholomews Hosp, Barts Heart Ctr, Dept Cardiac Electrophysiol, London EC1A 7BE, England
[2] Oxford Univ Hosp NHS Fdn Trust, John Radcliffe Hosp, Oxford Heart Ctr, Dept Cardiol, Oxford, England
[3] St George Hosp, Dept Cardiol, London, England
[4] St Anthony Hosp, Dept Cardiol, Sutton, Surrey, England
关键词
ablation index; atrial fibrillation; pulmonary vein isolation; CONTACT FORCE; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; CATHETER ABLATION; RECONNECTION; TRIAL;
D O I
10.1111/jce.13813
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. Methods Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. Results One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 omega, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group (P = 0.186). Conclusion High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 50 条
  • [31] Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter
    Evonich, Rudolph F.
    Nori, David M.
    Haines, David E.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (01) : 29 - 36
  • [32] Cryoballoon ablation for pulmonary vein isolation
    Andrade, Jason G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (08) : 2128 - 2135
  • [33] Impact of a time-to-effect-guided ablation protocol in cryoballoon ablation on the durability of pulmonary vein isolation
    Rexha, Enida
    Heeger, Christian-Hendrik
    Maack, Sabrina
    Rottner, Laura
    Wohlmuth, Peter
    Lemes, Christine
    Maurer, Tilman
    Reissmann, Bruno
    Rillig, Andreas
    Mathew, Shibu
    Sohns, Christian
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Metzner, Andreas
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (06) : 1096 - 1103
  • [34] High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation—markers of arrhythmia recurrence?
    Pedro A. Sousa
    Luís Puga
    Sérgio Barra
    Diana Campos
    Natália António
    Luís Elvas
    Lino Gonçalves
    Journal of Interventional Cardiac Electrophysiology, 2022, 65 : 115 - 121
  • [35] Impact of baseline impedance of pulmonary vein antrum on success of catheter ablation for paroxysmal atrial fibrillation guided by ablation index
    Sun, Yuanjun
    Xiao, Xianjie
    Yin, Xiaomeng
    Gao, Lianjun
    Yu, Xiaohong
    Zhang, Rongfeng
    Wang, Zhongzhen
    Dai, Shiyu
    Yang, Yanzong
    Xia, Yunlong
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [36] Comparison of Second-Generation Cryoballoon Ablation and Quantitative Radiofrequency Ablation Guided by Ablation Index for Atrial Fibrillation
    Yan, Qin-Dan
    Gong, Ke-Zeng
    Chen, Xue-Hai
    Chen, Jian-Hua
    Xu, Zhe
    Wang, Wei-Wei
    Zhang, Fei-Long
    ANGIOLOGY, 2024, 75 (05) : 462 - 471
  • [37] Influence of ablation index on the incidence of cardiac tamponade complicating pulmonary vein isolation
    Reinsch, Nico
    Fueting, Anna
    Buchholz, Jochen
    Ruprecht, Ute
    Neven, Kars
    HERZ, 2021, 46 : 228 - 234
  • [38] Role of adenosine-guided pulmonary vein isolation in patients undergoing catheter ablation for atrial fibrillation: a meta-analysis
    Chen, Yi-He
    Lin, Hui
    Xie, Cheng-Long
    Hou, Jian-Wen
    Li, Yi-Gang
    EUROPACE, 2017, 19 (04): : 552 - 559
  • [39] Pulmonary vein isolation guided by moderate ablation index targets combined with strict procedural endpoints for patients with paroxysmal atrial fibrillation
    Wang, Yan-Jiang
    Tian, Ying
    Shi, Liang
    Zeng, Li-Jun
    Xie, Bo-qia
    Li, Xue-xun
    Yang, Xin-Chun
    Liu, Xing-Peng
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (07) : 1842 - 1848
  • [40] Analysis of late reconnections after pulmonary vein isolation: Impact of interlesion contiguity and ablation index
    Pedrote, Alonso
    Acosta, Juan
    Frutos-Lopez, Manuel
    Jauregui-Garrido, Beatriz
    Alarcon, Francisco
    Arana-Rueda, Eduardo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (06): : 678 - 685