A multicentered evaluation of ablation at higher power guided by ablation index: Establishing ablation targets for pulmonary vein isolation

被引:88
|
作者
Dhillon, Gurpreet [1 ]
Ahsan, Syed [1 ]
Honarbakhsh, Shohreh [1 ]
Lim, Wei [1 ]
Baca, Marco [1 ]
Graham, Adam [1 ]
Srinivasan, Neil [1 ]
Sawhney, Vinit [1 ]
Sporton, Simon [1 ]
Schilling, Richard J. [1 ]
Chow, Anthony [1 ]
Ginks, Matthew [2 ]
Sohal, Manav [3 ,4 ]
Gallagher, Mark M. [3 ,4 ]
Hunter, Ross J. [1 ]
机构
[1] Barts Hlth NHS Trust, St Bartholomews Hosp, Barts Heart Ctr, Dept Cardiac Electrophysiol, London EC1A 7BE, England
[2] Oxford Univ Hosp NHS Fdn Trust, John Radcliffe Hosp, Oxford Heart Ctr, Dept Cardiol, Oxford, England
[3] St George Hosp, Dept Cardiol, London, England
[4] St Anthony Hosp, Dept Cardiol, Sutton, Surrey, England
关键词
ablation index; atrial fibrillation; pulmonary vein isolation; CONTACT FORCE; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; CATHETER ABLATION; RECONNECTION; TRIAL;
D O I
10.1111/jce.13813
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. Methods Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. Results One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 omega, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group (P = 0.186). Conclusion High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 50 条
  • [21] Treatment of Atrial Fibrillation Using Ablation Index-Guided Contact Force Ablation: A Matching-Adjusted Indirect Comparison to Cryoballoon Ablation
    Hussein, Ahmed
    Gupta, Dhiraj
    De Potter, Tom
    Spin, Paul
    Eaton, Kiefer
    Goldstein, Laura
    Velleca, Maria
    Costa, Graca
    Grima, Daniel
    Patel, Leena
    Stabile, Giuseppe
    ADVANCES IN THERAPY, 2020, 37 (02) : 785 - 799
  • [22] Ablation index-guided pulmonary vein isolation can reduce early recurrences of atrial tachyarrhythmias: a propensity score-matched analysis
    Yasumoto, Koji
    Egami, Yasuyuki
    Ukita, Kohei
    Kawamura, Akito
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Tsuda, Masaki
    Okamoto, Naotaka
    Tanaka, Akihiro
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Shutta, Ryu
    Sakata, Yasushi
    Nishino, Masami
    Tanouchi, Jun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 64 (02) : 479 - 487
  • [23] High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation-markers of arrhythmia recurrence?
    Sousa, Pedro A.
    Puga, Luis
    Barra, Sergio
    Campos, Diana
    Antonio, Natalia
    Elvas, Luis
    Goncalves, Lino
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (01) : 115 - 121
  • [24] Ablation index-guided high-power ablation for superior vena cava isolation in patients with atrial fibrillation
    Cui, Luqian
    Cui, Shihua
    Dong, Shujuan
    Li, Jingchao
    Yu, Haijia
    Song, Huihui
    Han, Yongmei
    Chu, Yingjie
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [25] Ablation guided by STAR-mapping in addition to pulmonary vein isolation is superior to pulmonary vein isolation alone or in combination with CFAE/linear ablation for persistent AF
    Honarbakhsh, Shohreh
    Schilling, Richard J.
    Providencia, Rui
    Dhillon, Gurpreet
    Bajomo, Omotomilola
    Keating, Emily
    Finlay, Malcolm
    Hunter, Ross J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (02) : 200 - 209
  • [26] Use of Ablation Index-Guided Ablation Results in High Rates of Durable Pulmonary Vein Isolation and Freedom From Arrhythmia in Persistent Atrial Fibrillation Patients The PRAISE Study Results
    Hussein, Ahmed
    Das, Moloy
    Riva, Stefania
    Morgan, Maureen
    Ronayne, Christina
    Sahni, Ankita
    Shaw, Matthew
    Todd, Derick
    Hall, Mark
    Modi, Simon
    Natale, Andrea
    Dello Russo, Antonio
    Snowdon, Richard
    Gupta, Dhiraj
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2018, 11 (09): : e006576
  • [27] Impact of ablation index settings on pulmonary vein reconnection
    Lepillier, A.
    Strisciuglio, T.
    De Ruvo, E.
    Scaglione, M.
    Anselmino, M.
    Sebag, F. A.
    Pecora, D.
    Gallagher, M. M.
    Rillo, M.
    Viola, G.
    Pisano, E.
    Abbey, S.
    Lamberti, F.
    Pani, A.
    Zucchelli, G.
    Sgarito, G.
    De Simone, A.
    Bertaglia, E.
    Solimene, F.
    Stabile, Giuseppe
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 63 (01) : 133 - 142
  • [28] Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation
    Yasuyuki Egami
    Masami Nishino
    Hiroaki Nohara
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Akito Kawamura
    Hitoshi Nakamura
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masamichi Yano
    Jun Tanouchi
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1571 - 1580
  • [29] Pulmonary vein isolation using radiofrequency ablation
    Iden L.
    Busch S.
    Steven D.
    Tilz R.R.
    Shin D.-I.
    Chun K.J.
    Estner H.
    Bourier F.
    Duncker D.
    Sommer P.
    Metzner A.
    Maurer T.
    Ewertsen N.-C.
    Jansen H.
    Rillig A.
    Johnson V.
    Althoff T.
    Herzschrittmachertherapie + Elektrophysiologie, 2021, 32 (3) : 395 - 405
  • [30] Lower contact force predicts right pulmonary vein carina breakthrough after ablation index-guided pulmonary vein isolation using high-power short-duration
    Chen, Wei-Tso
    Chung, Fa-Po
    Lin, Yenn-Jiang
    Chang, Shih-Lin
    Lo, Li-Wei
    Hu, Yu-Feng
    Tuan, Ta-Chuan
    Chao, Tze-Fan
    Liao, Jo-Nan
    Lin, Chin-Yu
    Chang, Ting-Yung
    Kuo, Ling
    Wu, Cheng-, I
    Liu, Chih-Min
    Liu, Shin-Huei
    Hsieh, Yu-Cheng
    Li, Cheng-Hung
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (01) : 60 - 68