A multicentered evaluation of ablation at higher power guided by ablation index: Establishing ablation targets for pulmonary vein isolation

被引:89
作者
Dhillon, Gurpreet [1 ]
Ahsan, Syed [1 ]
Honarbakhsh, Shohreh [1 ]
Lim, Wei [1 ]
Baca, Marco [1 ]
Graham, Adam [1 ]
Srinivasan, Neil [1 ]
Sawhney, Vinit [1 ]
Sporton, Simon [1 ]
Schilling, Richard J. [1 ]
Chow, Anthony [1 ]
Ginks, Matthew [2 ]
Sohal, Manav [3 ,4 ]
Gallagher, Mark M. [3 ,4 ]
Hunter, Ross J. [1 ]
机构
[1] Barts Hlth NHS Trust, St Bartholomews Hosp, Barts Heart Ctr, Dept Cardiac Electrophysiol, London EC1A 7BE, England
[2] Oxford Univ Hosp NHS Fdn Trust, John Radcliffe Hosp, Oxford Heart Ctr, Dept Cardiol, Oxford, England
[3] St George Hosp, Dept Cardiol, London, England
[4] St Anthony Hosp, Dept Cardiol, Sutton, Surrey, England
关键词
ablation index; atrial fibrillation; pulmonary vein isolation; CONTACT FORCE; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; CATHETER ABLATION; RECONNECTION; TRIAL;
D O I
10.1111/jce.13813
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. Methods Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. Results One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 omega, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group (P = 0.186). Conclusion High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 30 条
[1]   High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability [J].
Barkagan, Michael ;
Contreras-Valdes, Fernando M. ;
Leshem, Eran ;
Buxton, Alfred E. ;
Nakagawa, Hiroshi ;
Anter, Elad .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (09) :1287-1296
[2]   Five seconds of 50-60 W radio frequency atrial ablations were transmural and safe: an in vitro mechanistic assessment and force-controlled in vivo validation [J].
Bhaskaran, Abhishek ;
Chik, William ;
Pouliopoulos, Jim ;
Nalliah, Chrishan ;
Qian, Pierre ;
Barry, Tony ;
Nadri, Fazlur ;
Samanta, Rahul ;
Tran, Ying ;
Thomas, Stuart ;
Kovoor, Pramesh ;
Thiagalingam, Aravinda .
EUROPACE, 2017, 19 (05) :874-880
[3]   Morphological evidence of muscular connections between contiguous pulmonary venous orifices: Relevance of the interpulmonary isthmus for catheter ablation in atrial fibrillation [J].
Cabrera, Jose Angel ;
Ho, Siew Yen ;
Climent, Vicente ;
Fuertes, Beatriz ;
Murillo, Margarita ;
Sanchez-Quintana, Damian .
HEART RHYTHM, 2009, 6 (08) :1192-1198
[4]  
Calkins H, 2017, J ARRYTHM, V33, P369, DOI 10.1016/j.joa.2017.08.001
[5]   Sites With Small Impedance Decrease During Catheter Ablation for Atrial Fibrillation Are Associated With Recovery of Pulmonary Vein Conduction [J].
Chinitz, Jason S. ;
Kapur, Sunil ;
Barbhaiya, Chirag ;
Kumar, Saurabh ;
John, Roy ;
Epstein, Laurence M. ;
Tedrow, Usha ;
Stevenson, William G. ;
Michaud, Gregory F. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (12) :1390-1398
[6]   Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values [J].
Das, Moloy ;
Loveday, Jonathan J. ;
Wynn, Gareth J. ;
Gomes, Sean ;
Saeed, Yawer ;
Bonnett, Laura J. ;
Waktare, Johan E. P. ;
Todd, Derick M. ;
Hall, Mark C. S. ;
Snowdon, Richard L. ;
Modi, Simon ;
Gupta, Dhiraj .
EUROPACE, 2017, 19 (05) :775-783
[7]   Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force-Guided Pulmonary Vein Isolation Identifying the Weakest Link in the Ablation Chain [J].
El Haddad, Milad ;
Taghji, Philippe ;
Phlips, Thomas ;
Wolf, Michael ;
Demolder, Anthony ;
Choudhury, Rajin ;
Knecht, Sebastien ;
Vandekerckhove, Yves ;
Tavernier, Rene ;
Nakagawa, Hiroshi ;
Duytschaever, Mattias .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2017, 10 (04)
[8]  
Fichtner Stephanie, 2015, Indian Pacing Electrophysiol J, V15, P152, DOI 10.1016/j.ipej.2015.07.004
[9]   Initial clinical results with the ThermoCool® SmartTouch® Surround Flow catheter [J].
Gonna, Hanney ;
Domenichini, Giulia ;
Zuberi, Zia ;
Norman, Mark ;
Kaba, Riyaz ;
Grimster, Alexander ;
Gallagher, Mark M. .
EUROPACE, 2017, 19 (08) :1317-1321
[10]   Impact of surround flow catheter tip irrigation in contact force ablation on the incidence of asymptomatic oesophageal lesions after atrial fibrillation ablation: a prospective comparative study [J].
Halbfass, Philipp ;
Nentwich, Karin ;
Krug, Joachim ;
Roos, Markus ;
Sonne, Kai ;
Ene, Elena ;
Hamm, Karsten ;
Barth, Sebastian ;
Szollosi, Attila ;
Fochler, Franziska ;
Mugge, Andreas ;
Lusebrink, Ulrich ;
Deneke, Thomas .
EUROPACE, 2017, 19 (07) :1116-1122